<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "http://dtd.nlm.nih.gov/publishing/2.0/journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article" dtd-version="2.0">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">JMU</journal-id>
      <journal-id journal-id-type="nlm-ta">JMIR Mhealth Uhealth</journal-id>
      <journal-title>JMIR mHealth and uHealth</journal-title>
      <issn pub-type="epub">2291-5222</issn>
      <publisher>
        <publisher-name>JMIR Publications</publisher-name>
        <publisher-loc>Toronto, Canada</publisher-loc>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">v7i3e11251</article-id>
      <article-id pub-id-type="pmid">30843867</article-id>
      <article-id pub-id-type="doi">10.2196/11251</article-id>
      <article-categories>
        <subj-group subj-group-type="heading">
          <subject>Original Paper</subject>
        </subj-group>
        <subj-group subj-group-type="article-type">
          <subject>Original Paper</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>See-Through Type 3D Head-Mounted Display–Based Surgical Microscope System for Microsurgery: A Feasibility Study</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="editor">
          <name>
            <surname>Eysenbach</surname>
            <given-names>Gunther</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Moscote</surname>
            <given-names>Luis</given-names>
          </name>
        </contrib>
        <contrib contrib-type="reviewer">
          <name>
            <surname>Hwang</surname>
            <given-names>Jae Youn</given-names>
          </name>
        </contrib>
      </contrib-group>
      <contrib-group>
        <contrib contrib-type="author" id="contrib1" equal-contrib="yes">
          <name name-style="western">
            <surname>Kim</surname>
            <given-names>Cheol-Hwan</given-names>
          </name>
          <degrees>MEng</degrees>
          <xref rid="aff1" ref-type="aff">1</xref>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-5591-4147</ext-link>
        </contrib>
        <contrib contrib-type="author" id="contrib2" equal-contrib="yes">
          <name name-style="western">
            <surname>Ryu</surname>
            <given-names>Seon-Young</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff2" ref-type="aff">2</xref>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-7594-6162</ext-link>
        </contrib>
        <contrib contrib-type="author" id="contrib3">
          <name name-style="western">
            <surname>Yoon</surname>
            <given-names>Ji-Young</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff3" ref-type="aff">3</xref>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-8588-8664</ext-link>
        </contrib>
        <contrib contrib-type="author" id="contrib4">
          <name name-style="western">
            <surname>Lee</surname>
            <given-names>Hyoung-Kwon</given-names>
          </name>
          <degrees>BEng</degrees>
          <xref rid="aff4" ref-type="aff">4</xref>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0001-9611-1087</ext-link>
        </contrib>
        <contrib contrib-type="author" id="contrib5">
          <name name-style="western">
            <surname>Choi</surname>
            <given-names>Nak-Gu</given-names>
          </name>
          <degrees>BEng</degrees>
          <xref rid="aff5" ref-type="aff">5</xref>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0001-5832-6757</ext-link>
        </contrib>
        <contrib contrib-type="author" id="contrib6">
          <name name-style="western">
            <surname>Park</surname>
            <given-names>Il-Ho</given-names>
          </name>
          <degrees>MD, PhD</degrees>
          <xref rid="aff6" ref-type="aff">6</xref>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0002-7011-6071</ext-link>
        </contrib>
        <contrib contrib-type="author" id="contrib7" corresp="yes">
          <name name-style="western">
            <surname>Choi</surname>
            <given-names>Hae-Young</given-names>
          </name>
          <degrees>PhD</degrees>
          <xref rid="aff3" ref-type="aff">3</xref>
          <address>
            <institution>Medical Device Development Center</institution>
            <institution>Daegu-Gyeongbuk Medical Innovation Foundation</institution>
            <addr-line>80, Cheombok-ro</addr-line>
            <addr-line>Dong-Gu</addr-line>
            <addr-line>Daegu, 41061</addr-line>
            <country>Republic of Korea</country>
            <phone>82 53 790 5617</phone>
            <fax>82 53 790 5519</fax>
            <email>chy4745@gmail.com</email>
          </address>
          <ext-link ext-link-type="orcid">http://orcid.org/0000-0001-7962-2029</ext-link>
        </contrib>
      </contrib-group>
      <aff id="aff1">
      <label>1</label>
      <institution>Institute of Advanced Convergence Technology</institution>
      <institution>Kyungpook National University</institution>  
      <addr-line>Daegu</addr-line>
      <country>Republic of Korea</country></aff>
      <aff id="aff2">
      <label>2</label>
      <institution>Department of Creative IT Engineering</institution>
      <institution>Pohang University of Science and Technology</institution>  
      <addr-line>Pohang</addr-line>
      <country>Republic of Korea</country></aff>
      <aff id="aff3">
      <label>3</label>
      <institution>Medical Device Development Center</institution>
      <institution>Daegu-Gyeongbuk Medical Innovation Foundation</institution>  
      <addr-line>Daegu</addr-line>
      <country>Republic of Korea</country></aff>
      <aff id="aff4">
      <label>4</label>
      <institution>Research Laboratory</institution>
      <institution>Green Optics CO</institution>  
      <addr-line>Cheongju</addr-line>
      <country>Republic of Korea</country></aff>
      <aff id="aff5">
      <label>5</label>
      <institution>Research Lab</institution>
      <institution>Hulust CO</institution>  
      <addr-line>Wonju</addr-line>
      <country>Republic of Korea</country></aff>
      <aff id="aff6">
      <label>6</label>
      <institution>Department of Otorhinolaryngology</institution>
      <institution>Korea University Medical College</institution>  
      <addr-line>Seoul</addr-line>
      <country>Republic of Korea</country></aff>
      <author-notes>
        <corresp>Corresponding Author: Hae-Young Choi 
        <email>chy4745@gmail.com</email></corresp>
      </author-notes>
      <pub-date pub-type="collection"><month>03</month><year>2019</year></pub-date>
      <pub-date pub-type="epub">
        <day>07</day>
        <month>03</month>
        <year>2019</year>
      </pub-date>
      <volume>7</volume>
      <issue>3</issue>
      <elocation-id>e11251</elocation-id>
      <!--history from ojs - api-xml-->
      <history>
        <date date-type="received">
          <day>27</day>
          <month>6</month>
          <year>2018</year>
        </date>
        <date date-type="rev-request">
          <day>6</day>
          <month>9</month>
          <year>2018</year>
        </date>
        <date date-type="rev-recd">
          <day>26</day>
          <month>10</month>
          <year>2018</year>
        </date>
        <date date-type="accepted">
          <day>13</day>
          <month>11</month>
          <year>2018</year>
        </date>
      </history>
      <copyright-statement>©Cheol-Hwan Kim, Seon-Young Ryu, Ji-Young Yoon, Hyoung-Kwon Lee, Nak-Gu Choi, Il-Ho Park, Hae-Young Choi. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 07.03.2019.</copyright-statement>
      <copyright-year>2019</copyright-year>
      <license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/">
        <p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.</p>
      </license>
      <self-uri xlink:href="https://mhealth.jmir.org/2019/3/e11251/" xlink:type="simple"/>
      <abstract>
        <sec sec-type="background">
          <title>Background</title>
          <p>The surgical microscope is used primarily for microsurgeries, which are more complicated than other surgical procedures and require delicate tasks for a long time. Therefore, during these surgical procedures, surgeons experience back and neck pain. To solve this problem, new technology, such as wearable displays, is required to help surgeons maintain comfortable postures and enjoy advanced functionality during microsurgery.</p>
        </sec>
        <sec sec-type="objective">
          <title>Objective</title>
          <p>The objective of this study was to develop a surgical microscope system that would work with wearable devices. It would include a head-mounted display (HMD) that can offer 3D surgical images and allow a flexible and comfortable posture instead of fixed eyepieces of surgical microscope and can also provide peripheral visual field with its optical see-through function.</p>
        </sec>
        <sec sec-type="methods">
          <title>Methods</title>
          <p>We designed and fabricated a surgical microscope system that incorporates a see-through type 3D HMD, and we developed an image processing software to provide better image quality. The usability of the proposed system was confirmed with preclinical examination. Seven ENT (ear, nose, and throat) surgical specialists and 8 residents performed a mock surgery—axillary lymph node dissection on a rat. They alternated between looking through the eyepieces of the surgical microscope and viewing a 3D HMD screen connected to the surgical microscope. We examined the success of the surgery and asked the specialists and residents to grade eye fatigue on a scale of 0 (none) to 6 (severe) and posture discomfort on a scale of 1 (none) to 5 (severe). Furthermore, a statistical comparison was performed using 2-tailed paired t test, and <italic>P</italic>=.00083 was considered significant.</p>
        </sec>
        <sec sec-type="results">
          <title>Results</title>
          <p>Although 3D HMD case showed a slightly better result regarding visual discomfort (<italic>P</italic>=.097), the average eye fatigue was not significantly different between eyepiece and 3D HMD cases (<italic>P</italic>=.79). However, the average posture discomfort, especially in neck and shoulder, was lower with 3D HMD display use than with eyepiece use (<italic>P</italic>=.00083).</p>
        </sec>
        <sec sec-type="conclusions">
          <title>Conclusions</title>
          <p>We developed a see-through type 3D HMD–based surgical microscope system and showed through preclinical testing that the system could help reduce posture discomfort. The proposed system, with its advanced functions, could be a promising new technique for microsurgery.</p>
        </sec>
      </abstract>
      <kwd-group>
        <kwd>3D imaging</kwd>
        <kwd>head-mounted display</kwd>
        <kwd>microsurgery</kwd>
        <kwd>surgical microscope</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="introduction">
      <title>Introduction</title>
      <p>The surgical microscope is mainly used for microsurgeries, such as in neurosurgical application, ENT (ear, nose, and throat) surgeries, ophthalmic surgeries, plastic and reconstructive surgeries, and dental treatments. Microsurgery requires accurate and stable task performance with small and delicate instruments, and surgeons spend long sessions with their eyes on the eyepieces of the microscope. Therefore, due to their awkward static postures during operations, surgeons experience back and neck pain, musculoskeletal fatigue, and injuries [<xref ref-type="bibr" rid="ref1">1</xref>-<xref ref-type="bibr" rid="ref4">4</xref>]. In a national cross-sectional survey of 325 ENT consultants by Babar-Craig et al [<xref ref-type="bibr" rid="ref2">2</xref>], 72% reported having experienced either back or neck pain or both, with most reports coming from otologists, relating their symptoms to lengthy microscopic work and prolonged sitting. Overall, 53% of respondents attributed their symptoms directly to previously performed ENT surgeries. Other predisposing factors include static postures and bending during endoscopic procedures, similar to their general surgical colleagues [<xref ref-type="bibr" rid="ref2">2</xref>]. A survey of 5 different specialists in the United Kingdom—general surgery, otorhinolaryngology, plastic surgery, orthopedics, and trauma surgery and neurosurgery—indicated that the back and neck were the most common areas of pain. Posture was the most common cause of pain (46%), followed by the use of microscopes or surgical instruments (21% each) and surgical loupes or head-mounted lights (11%) [<xref ref-type="bibr" rid="ref3">3</xref>]. However, many surgeons pay little attention to their health, and their work-related illness has been reported to be above average compared with that of professionals from other industries [<xref ref-type="bibr" rid="ref1">1</xref>]. Therefore, new technologies should be adopted in the workplace to reduce posture-related discomfort, provide better visualization during surgical procedures, and help with pain management.</p>
      <p>Heads-up microscopy using a high-definition (HD) 3D monitor has been proposed as an ergonomic alternative. This system transmits the surgical microscopic images to a 3D monitor for the surgeon and assistants to view in more comfortable positions. In addition, it allows the surgeon to recognize the surgical environment easily [<xref ref-type="bibr" rid="ref5">5</xref>]. However, in heads-up microscopy, a surgeon’s head and eyes are directed toward a monitor, which causes an eye-hand coordination mismatch and requires an uncomfortable posture for surgeons. Head-mounted displays (HMDs) have been adopted to solve the abovementioned drawbacks in the case of endoscopy and laparoscopy, which use the same kinds of 3D monitors [<xref ref-type="bibr" rid="ref6">6</xref>-<xref ref-type="bibr" rid="ref13">13</xref>]. The use of HMD helps eliminate these problems by delivering optical information directly to the surgeon’s eyes, independent of the head and body position and the position of the sources of images. Therefore, HMDs can relieve back and neck strain and improve technical proficiency. In addition, 3D functions of the HMD-based laparoscopic system and endoscopic surgery system provide benefits such as improved operation times, minimized complications, shortened learning curves, and greater surgeon comfort [<xref ref-type="bibr" rid="ref14">14</xref>,<xref ref-type="bibr" rid="ref15">15</xref>].</p>
      <p>Despite the several advantages of the HMD, the associated disadvantages still limit its use in surgery. Many of the proposed HMDs have inadequate resolution, and they are bulky, cave-like, and heavy [<xref ref-type="bibr" rid="ref6">6</xref>-<xref ref-type="bibr" rid="ref10">10</xref>]. Although a higher-resolution HMD has recently been proposed for endoscopy, it has a fully opaque and closed, nonsee-through configuration [<xref ref-type="bibr" rid="ref11">11</xref>-<xref ref-type="bibr" rid="ref13">13</xref>]. Because this type of HMD can only deliver virtual information to the eye, it is difficult to obtain a direct physical view and to observe the surgical environment in the operating room. Therefore, in this study, we propose a surgical microscope system based on a high-resolution 3D HMD with a see-through configuration that enables optical superposition of digital information onto the physical view. Using the proposed system, 3D surgical images can be observed with more comfortable postures, and a peripheral view of the surgical field can also be easily accessed during microsurgery via the see-through configuration. We designed and fabricated a stereoscopic surgical microscope and see-through 3D HMD and developed image processing software. The feasibility of the proposed HMD-based surgical microscope system was evaluated with preclinical examination, and the results were compared with the results obtained with the conventional eyepieces of the system.</p>
    </sec>
    <sec sec-type="methods">
      <title>Methods</title>
      <sec>
        <title>Surgical Microscope System Using Head-Mounted Display</title>
        <p>We implemented a surgical microscope system incorporating a see-through type 3D HMD and image processing computer, as shown in <xref ref-type="fig" rid="figure1">Figure 1</xref> (image on the left). A surgical microscope was developed that comprises a binocular headpiece with adjustable eyepieces and 2 charge-coupled device (CCD) cameras, optical see-through type 3D HMD mounted on a headband, and image processing software. The measured surgical images are directly observed through eyepieces, and the measured surgical images from the 2 CCD cameras on the surgical microscope are sent to an image processing computer for better image quality and for 3D image reconstruction in real time, as described in <xref ref-type="fig" rid="figure1">Figure 1</xref> (image on the right). The processed images are displayed on a monitor and the proposed 3D HMD. Furthermore, two-dimensional (2D) side-by-side images are displayed on the monitor, and 3D surgical images are displayed by the HMD.</p>
        <fig id="figure1" position="float">
          <label>Figure 1</label>
          <caption>
            <p>Left: surgical microscope system based on see-through type 3D head-mounted display (HMD); right: surgical images measured using 2 charge-coupled device cameras are displayed on a monitor in two dimensions and displayed on HMD in 3D after the image processing procedure.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig1.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
      <sec>
        <title>Stereoscopic Microscope</title>
        <p>We designed and fabricated a stereoscopic microscope with 2 CCD cameras for use as a surgical microscope. The device used a binocular design with a single common main objective, as described in <xref ref-type="fig" rid="figure2">Figure 2</xref>. The microscope comprised a light source, 2 CCD cameras, and optical components: one common main objective, a pair of turrets, a prism, an eyepiece, and a closed-circuit television (CCTV) lens. A white light emitting diode light source (NET-260SL, Mega Medical Co Ltd) was attached to the illumination port of the microscope. The continuous zooming turret, having a focusing component, a zooming component, and a compensating component was adopted, and it was connected to a DC motor and foot switch. A varifocal lens with a motor drive was used for autofocusing. The step control was 0.18 degrees, and the autofocusing precision was 1.2 µm. The magnification ratio was 1× to 4×, and the object distance was 200-400 mm. The CCTV lens was connected to the turret lens, and it delivered images to the CCD cameras. HD CCD cameras (HDC-SD041BS, WatchCam Co Ltd) were attached next to the CCTV lenses. The camera had a 1/3-inch complementary metal-oxide-semiconductor sensor, and the total pixels were 2010 (H)×1108 (V). The video output was set to 1280×720, which was the same as the pixel size of the microdisplay for the HMD. The measured resolution of the microscope was 79 line pairs (lp) at 200-mm distance and 105 lp at 400-mm distance. The microscope was implemented with water resistance of IPX4. The specifications of the optical system of the proposed stereoscopic microscope are listed in <xref ref-type="table" rid="table1">Table 1</xref>.</p>
        <fig id="figure2" position="float">
          <label>Figure 2</label>
          <caption>
            <p>Left: optical design of the stereoscopic microscope; right: picture of the fabricated stereoscopic microscope. CCTV: closed-circuit television; CCD: charge-coupled device; CMO: common main objective.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig2.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <table-wrap position="float" id="table1">
          <label>Table 1</label>
          <caption>
            <p>Specification of the optical system of the proposed stereoscopic microscope.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="500"/>
            <col width="500"/>
            <thead>
              <tr valign="top">
                <td>Feature</td>
                <td>Specification</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Resolution</td>
                <td>79 line pairs at 200 mm</td>
              </tr>
              <tr valign="top">
                <td>Charge-coupled device resolution</td>
                <td>1280×720</td>
              </tr>
              <tr valign="top">
                <td>Magnification</td>
                <td>Continuous zoom (1:4)</td>
              </tr>
              <tr valign="top">
                <td>Object distance</td>
                <td>200-400 mm</td>
              </tr>
              <tr valign="top">
                <td>Autofocusing resolution</td>
                <td>1.2 µm</td>
              </tr>
              <tr valign="top">
                <td>Waterproof</td>
                <td>IPX4</td>
              </tr>
              <tr valign="top">
                <td>Display</td>
                <td>Eyepieces, monitor, head-mounted display</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
      </sec>
      <sec>
        <title>See-Through Type 3D Head-Mounted Display</title>
        <p>A see-through type 3D HMD was designed and fabricated for obtaining not only the 3D surgical image but also a direct physical sight. The binocular design has 2 separate displays with 2 input channels, 1 for each eye, which makes it possible to observe stereoscopic images. Optics designing software (ZEMAX LLC, Optic Studio) was used to create an optical design using 2 prisms and a curved mirror. As shown in <xref ref-type="fig" rid="figure3">Figure 3</xref> (top left image), the image from the microdisplay was enlarged and reflected by the curved mirror and then transferred to the eye after being reflected on the surface of the prism. Using a compensation prism, the sight from outside can also be seen at eye position without distortion. A polarizing film was attached on the prism surface, and a 1/4 λ wave plate was placed between the prism and the curved mirror to minimize optical power loss. The polarizing film can only transmit p-waves and reflect s-waves, and the efficiencies of both are over 80%. Therefore, although the nonpolarized input beam is reduced to half of its original amount by the polarizing film, 40% of p-waves are transmitted. The transmitted p-waves are rotated to s-waves by passing through the 1/4 wave plate twice. Finally, over 34% of the input beam is delivered to the eye. The curved mirrors are fabricated of a glass material (N-BK7). To reduce the weight of optical module, polymethyl methacrylate was used in the fabrication of the optical prisms that are most bulky part in the optical module, and the outside of the effective optical path in optical prisms were cut, as shown in <xref ref-type="fig" rid="figure3">Figure 3</xref> (top right image). Optical components were attached using optical adhesive, and 2 optical modules were placed at the designed positions in relation to the microdisplay.</p>
        <p>A 0.61-inch organic light emitting diode display (MDP02BCWF, MICROOLED) with pixel sizes of 1280×1024 was used as a high-resolution microdisplay. The output pixels were set to 1280×720 pixels. The microdisplay driving board with a high-definition multimedia interface (HDMI) and USB power port was custom fabricated. The electric control board was assembled with the optical module, as shown in <xref ref-type="fig" rid="figure3">Figure 3</xref> (top right). The integrated HMD module was mounted on a headband, and the HDMI cable and USB power cable were housed at the rear of the headband for comfortable weight balance. <xref ref-type="fig" rid="figure3">Figure 3</xref> (bottom images) shows the design of the HMD and the fabricated item itself. The headband is designed to adjust in size to fit any user’s head. The height and angle of the HMD module were made to be adjustable to match a user’s eye. The performance of HMD was measured using a home-constructed measurement system and approved target. The measured field of view was 41 degrees in the diagonal direction, and the distortion was 2.4%. The eye relief was 15 mm, and the horizontal and vertical dimensions of the eye box were 10 mm and 4 mm, respectively. The measured weight of the HMD, without the headband, was about 92 g. To deliver the surgical image dominantly, a polarization window with &lt;10% transparency was applied in front of the HMD. Therefore, we can observe the 3D surgical image as the primary image in the field of view and can also acquire a peripheral view outside the effective area. The specifications of the HMD are listed in <xref ref-type="table" rid="table2">Table 2</xref>.</p>
        <fig id="figure3" position="float">
          <label>Figure 3</label>
          <caption>
            <p>Top left: optical design of see-through type 3D head-mounted display (HMD); top right: integration of the control board and the optical module; bottom left: headband design; bottom right: fabricated see-through type 3D HMD.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig3.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <table-wrap position="float" id="table2">
          <label>Table 2</label>
          <caption>
            <p>Specification of the head-mounted display.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="500"/>
            <col width="500"/>
            <thead>
              <tr valign="top">
                <td>Feature</td>
                <td>Specification</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td>Resolution</td>
                <td>High definition (1280×720)</td>
              </tr>
              <tr valign="top">
                <td>Display</td>
                <td>Organic light emitting diode</td>
              </tr>
              <tr valign="top">
                <td>Type</td>
                <td>See-through (2D or 3D)</td>
              </tr>
              <tr valign="top">
                <td>Field of view</td>
                <td>41 degrees (diagonal)</td>
              </tr>
              <tr valign="top">
                <td>Eye Relief</td>
                <td>15 mm</td>
              </tr>
              <tr valign="top">
                <td>Eye box</td>
                <td>10 mm×4 mm (H×V)</td>
              </tr>
              <tr valign="top">
                <td>Distortion</td>
                <td>2.4%</td>
              </tr>
              <tr valign="top">
                <td>Interface</td>
                <td>High-definition multimedia interface</td>
              </tr>
              <tr valign="top">
                <td>Weight</td>
                <td>92 g (without headband)</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <fig id="figure4" position="float">
          <label>Figure 4</label>
          <caption>
            <p>Top: image processing flow; bottom: system control and image processing software.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig4.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
      <sec>
        <title>Image Processing Software</title>
        <p>The key roles of the image processing software are to improve the image quality and transform the format for 3D HMD. In general, the side-by-side 3D image is made from half-size left and right images reduced in the horizontal dimension, but we used full-size left and right images to achieve a better image quality for medical applications. As shown in <xref ref-type="fig" rid="figure4">Figure 4</xref> (top image), the captured 1280×720 left and right microscope images are transformed into a 2560×720 side-by-side image for HMD through two main image processing procedures: stereo image alignment correction and color correction. The stereo image alignment correction function is intended to restore left and right image alignment error caused by optical misalignment of the microscope. In the stereo image alignment correction process, the left and right images are converted by homography matrix. The matched feature point pairs extracted using by Speeded-Up Robust Features algorithm in the left and right images are used to calculate the homography matrix [<xref ref-type="bibr" rid="ref16">16</xref>,<xref ref-type="bibr" rid="ref17">17</xref>]. After correcting the stereo image alignment, the vertical error of the matched feature points was 0%, the rotational error was 1.1°, and the zoom size error was 2%. The color correction function is intended to repair the color distortion caused by the characteristics of the camera image sensor and, therefore, to make the color of the image equal to the color of the real object. We used the colorimetric matching method to correct color distortion [<xref ref-type="bibr" rid="ref18">18</xref>,<xref ref-type="bibr" rid="ref19">19</xref>]. In this method, the characteristics of the camera sensor are modeled from the XYZ values of the original object measured using the color meter device and the RGB (red, green, and blue) values of the camera image. After finding the matrix of the camera model, the invert matrix of the camera matrix is used to convert the camera image to its original color. We used the 140-color ColorChecker to find the matrix of the camera model; after correcting the color, the average CIELAB color difference between the measured color and corrected color for the 140 patches was 4.35.</p>
        <p>In addition, we developed the graphical user interface for user convenience functions, such as still shot, recording, play, and pause, as shown in <xref ref-type="fig" rid="figure4">Figure 4</xref> (bottom image). Furthermore, camera settings such as brightness, contrast, and sharpness can be directly controlled, which reduces software load for image processing.</p>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>Results</title>
      <sec>
        <title>Head-Mounted Display–Based Surgical Microscope System Performance</title>
        <p>The performance of the proposed system was evaluated by measuring test samples of <italic>Capsicum annuum</italic>. <xref ref-type="fig" rid="figure5">Figure 5</xref> represents left and right images directly captured at the eyepieces (top left) and HMD (bottom left) at eye position. By those slightly different angled images, we can observe 3D images through the eyepieces and the HMD. Different brightness and fields of view were observed because of the different optics between the eyepieces and the CCD camera. Brighter images were observed through the eyepieces and better fields of view were observed via the HMD, as shown in <xref ref-type="fig" rid="figure5">Figure 5</xref> (top and bottom left images, respectively). The camera setting and image processing procedure were optimized to acquire microscope-like 3D reconstruction images from the HMD that were more comfortable to eyes. Through the HMD, we can mainly observe the measured object and can also recognize environmental situation from peripheral view due to its optical see-through design, as shown in <xref ref-type="fig" rid="figure5">Figure 5</xref> (top and bottom right images).</p>
      </sec>
      <sec>
        <title>Preclinical Study</title>
        <p>We tested the feasibility of the see-through type 3D HMD–based surgical microscope system through preclinical trial surgery. The preclinical experiment was conducted according to the protocol of the Korea University Medical Center. Male mice aged 8 weeks were used. Experimental methods involving animals were approved by the Institutional Animal Care and Use Committee of Korea University. Mice were anesthetized with 2.5% isoflurane. The surgical sites were aseptically prepared and draped to provide a sterile field. The axillary lymph nodes were exposed after dissection of the skin and fascia (<xref ref-type="fig" rid="figure6">Figure 6</xref>, top image); 3 lymph nodes were collected from each site. The collected lymph nodes were checked and confirmed by another surgeon. A nonabsorbable suture was used for skin closure. Suture removal was performed 7 days later under isoflurane anesthesia as necessary. Mice were checked-up once a day until suture removal, then once every week for 1 month.</p>
        <p>We used the proposed surgical microscope with and without the see-through type 3D HMD for comparison, as shown in <xref ref-type="fig" rid="figure6">Figure 6</xref> (bottom images). The experiment was a preclinical test of axillary lymph node dissection in white mice. Seven ENT surgical specialists and 8 residents participated in the test, all of whom were experts in microscopic procedures. The evaluation items were the success of the operation, the eye fatigue test, and the postural discomfort test.</p>
        <p>First, the success of the operation was evaluated with regard to 4 different categories, as shown in <xref ref-type="table" rid="table3">Table 3</xref>. The failure criteria for the preclinical trial surgery were as follows: (1) if the operation time exceeds 1 hour; (2) if the tester cannot collect &gt;6 lymph nodes; and (3) if white mice have been bleeding or are unable to survive.</p>
        <p>As shown in <xref ref-type="table" rid="table3">Table 3</xref>, the experimental results demonstrated that 6 trials of surgeries using the proposed 3D HMD–based surgical microscope were successfully performed without bleeding in mice. The average operation time was similar with eyepieces and with the 3D HMD.</p>
        <fig id="figure5" position="float">
          <label>Figure 5</label>
          <caption>
            <p>Top left: measured left and right images using eyepieces; bottom left: measured left and right images using head-mounted display (HMD); top and bottom right: a demonstration of the see-through type 3D HMD.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig5.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <fig id="figure6" position="float">
          <label>Figure 6</label>
          <caption>
            <p>Top: preclinical test of axillary lymph node dissection in white mice; bottom left: preclinical test using eyepieces; bottom right: preclinical test using see-through type 3D head-mounted display.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig6.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <table-wrap position="float" id="table3">
          <label>Table 3</label>
          <caption>
            <p>Comparison of preclinical experiment results obtained using head-mounted display (HMD) and eyepieces.</p>
          </caption>
          <table width="1000" cellpadding="5" cellspacing="0" border="1" rules="groups" frame="hsides">
            <col width="30"/>
            <col width="440"/>
            <col width="180"/>
            <col width="150"/>
            <col width="200"/>
            <thead>
              <tr valign="top">
                <td colspan="2">Category and device</td>
                <td>Result</td>
                <td>Success or Failure</td>
                <td>Experiment success criteria</td>
              </tr>
            </thead>
            <tbody>
              <tr valign="top">
                <td colspan="5"><bold>Average operation time</bold></td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>HMD</td>
                <td>21 minutes 41 seconds</td>
                <td>Success</td>
                <td rowspan="2">1 hour</td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>Eyepieces</td>
                <td>22 minutes 42 seconds</td>
                <td>Success</td>
              </tr>
              <tr valign="top">
                <td colspan="5"><bold>Number of lymph nodes sampled</bold></td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>HMD</td>
                <td>6</td>
                <td>Success</td>
                <td rowspan="2">6</td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>Eyepieces</td>
                <td>6</td>
                <td>Success</td>
              </tr>
              <tr valign="top">
                <td colspan="5"><bold>Bleeding</bold></td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>HMD</td>
                <td>No</td>
                <td>Success</td>
                <td rowspan="2">No</td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>Eyepieces</td>
                <td>No</td>
                <td>Success</td>
              </tr>
              <tr valign="top">
                <td colspan="5"><bold>Survival</bold></td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>HMD</td>
                <td>Survival</td>
                <td>Success</td>
                <td rowspan="2">Survival</td>
              </tr>
              <tr valign="top">
                <td><break/></td>
                <td>Eyepieces</td>
                <td>Survival</td>
                <td>Success</td>
              </tr>
            </tbody>
          </table>
        </table-wrap>
        <p>The eye fatigue test measured subjective fatigue from 0 to 7 points for tired eyes, sore or aching eyes, irritated eyes, dry eyes, eyestrain, hot or burning eyes, blurred vision, difficulty focusing, and visual discomfort. In addition, headache, dizziness, nausea, and decreased concentration were evaluated. The eye fatigue test was evaluated before and after the preclinical trial surgery tests.</p>
        <p>In the preclinical test using the eyepieces of the surgical microscope, the eye fatigue scores were in the order of tired eyes (2.3), difficulty focusing (1.9), and vision discomfort (1.9). Using the proposed 3D HMD technology, the results were in the order of tired eyes (1.9), difficulty focusing (1.7), and eyestrain (1.2). The 2-tailed paired <italic>t</italic> test of tired eyes showed no significant difference between the use of eyepieces and the use of HMD (<italic>P</italic>=.79). However, in the case of visual discomfort, the <italic>P</italic> value was .097 (<xref ref-type="fig" rid="figure7">Figure 7</xref>), which means that the HMD has the potential to help reduce visual discomfort.</p>
        <p>The posture discomfort test measured discomfort with a rating of 1 to 5 points for discomfort associated with the lower back, upper back, hand or wrist, elbow, arm, neck or shoulder, eye, and head after the preclinical test. After the preclinical test using the eyepieces of the surgical microscope, the posture discomfort scores were in the order of neck or shoulder (2.9), eyes (2.7), and upper back (2.5). Using the HMD-based surgical microscope, the scores were in the order of eyes (2.2), head (1.9), and neck or shoulder (1.8). The mean of the posture discomfort score with and without using the HMD was 12.5 and 18.5, respectively. The results of the paired <italic>t</italic> test of posture discomfort scores showed a significant difference between the use of the eyepieces and the use of the HMD (<italic>P</italic>=.00083; <xref ref-type="fig" rid="figure8">Figure 8</xref>); these results confirmed that the proposed see-through type 3D HMD can reduce posture discomfort, especially regarding neck and shoulder pain, during surgical procedures.</p>
        <p>We analyzed the total scores for eye fatigue and posture discomfort. Using the eyepieces, the eye fatigue and posture discomfort scores were distributed from 3 to 51 points (average 15.1) and 12 to 27 points (average 18.5), respectively. Using the 3D HMD, the eye fatigue and posture discomfort scores were distributed from 4 to 33 points (average 14.5) and 10 to 17 points (average 12.8), respectively. Paired <italic>t</italic> test results showed no significant difference between the 2 technologies regarding the total eye fatigue scores, but there was a significant difference regarding the total posture discomfort scores (<xref ref-type="fig" rid="figure9">Figure 9</xref>). In conclusion, posture discomfort can be reduced using the proposed see-through type 3D HMD instead of the traditional eyepieces of the surgical microscope.</p>
        <fig id="figure7" position="float">
          <label>Figure 7</label>
          <caption>
            <p>Results of eye fatigue test. HMD: head-mounted display.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig7.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <fig id="figure8" position="float">
          <label>Figure 8</label>
          <caption>
            <p>Results of posture discomfort test. HMD: head-mounted display.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig8.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
        <fig id="figure9" position="float">
          <label>Figure 9</label>
          <caption>
            <p>Comparison of eye fatigue and posture discomfort scores for head-mounted display (HMD) and eyepieces.</p>
          </caption>
          <graphic xlink:href="mhealth_v7i3e11251_fig9.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/>
        </fig>
      </sec>
    </sec>
    <sec sec-type="discussion">
      <title>Discussion</title>
      <sec>
        <title>Principal Findings</title>
        <p>Surgical microscopy is an indispensable system for microsurgery. Although with currently available systems, surgeons can match their eye-hand coordination during surgical procedures, their eyes must be kept on the fixed eyepieces of the microscope for long periods, which requires them to maintain uncomfortable postures that can cause a musculoskeletal disorder. To provide surgeons with the freedom to change their viewing positions, we proposed a high-resolution, see-through type 3D HMD–based surgical microscope system. With this system, surgeons can obtain high-definition 3D surgical images with more comfortable and flexible postures by acquiring the images from a 3D HMD mounted on a headband, instead of keeping their eyes on fixed eyepieces. Furthermore, surgeons can observe a broader surgical environment in addition to the local surgical field using the optical see-through type configuration in the HMD design. Although we used an optical window to block the intensity of the physical view over 90% to provide a brighter surgical image, the see-through type configuration helps in obtaining the peripheral view more easily than a nonsee-through type configuration.</p>
        <p>In this proposed system, we used a headband design to remove the weight from the user’s nose. In addition, we used light-weight material for the optical module, and the nonessential area was cut away to minimize the weight of the HMD. However, additional efforts are required to reduce the weight while maintaining a large field of view. Using a thin and light-weight optical module, such as a waveguide or light guide, an HMD with more compact glasses can be achieved [<xref ref-type="bibr" rid="ref20">20</xref>]. With recent technologies, additional functions of the HMD are easily accessible, such as voice control and a display of additional medical information. Using several HMDs, assistants or students can see the same surgical images as surgeons, which will be helpful in making surgeries and medical education more effective. We are planning to improve the proposed system in our future work.</p>
        <p>The results of the feasibility study conducted by preclinical trial surgery showed that the see-through type 3D HMD could provide surgical images with performance similar to that of conventional eyepieces in terms of eye fatigue. In this test, the eye fatigue scores of a few items, including dizziness, were shown to be slightly higher when the HMD was used. One of the main reasons for these increased scores was interpupillary distance (IPD) mismatch. Correspondence between the observer’s IPD and the distance between the optical centers of the binocular HMD is critical for visual comfort. In this work, we set a fixed IPD of 65 mm, a value within the IPD range (50-74 mm) of most adult females and males. Thus, some people who have a short or long IPD can feel dizzy or feel soreness in eyes. Such fatigue can be reduced by adopting adjustable frames of both optical modules for IPD adjustment. We plan to apply an IPD controllable frame in the next version of the HMD. In addition, horizontal, vertical, or rotational deviations of the input images to the eye can bring about eye fatigue or dizziness. Therefore, the alignment of the 2 cameras of the microscope and the 2 microdisplays is also important for reducing eye fatigue. In this work, alignment correction is included in the image processing software for the 2 camera alignments. In addition, fine alignment of the 2 microdisplays has been performed during the packaging process of the optical module.</p>
      </sec>
      <sec>
        <title>Conclusions</title>
        <p>In this study, we have introduced a high-resolution, see-through type 3D HMD–based surgical microscope system that is suitable for stable and comfortable microsurgery with advanced functions, such as flexibility of viewing posture and a broad surgical view. The results of the preclinical examination showed that the proposed system has sufficient performance to relieve posture discomfort. The proposed system would be advantageous in overall ENT surgery. To be specific, the main application fields are mastoidectomy and tympanoplasty because they both require long surgical times.</p>
      </sec>
    </sec>
  </body>
  <back>
    <glossary>
      <title>Abbreviations</title>
      <def-list>
        <def-item>
          <term id="abb1">CCD</term>
          <def>
            <p>charge-coupled device</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb2">ENT</term>
          <def>
            <p>ear, nose, and throat</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb3">HDMI</term>
          <def>
            <p>high-definition multimedia interface</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb4">HMD</term>
          <def>
            <p>head-mounted display</p>
          </def>
        </def-item>
        <def-item>
          <term id="abb5">IPD</term>
          <def>
            <p>interpupillary distance</p>
          </def>
        </def-item>
      </def-list>
    </glossary>
    <ack>
      <p>This work was supported by the Economic and Regional Cooperation Industry program funded by the Ministry of Trade, Industry &amp; Energy; the Information &amp; Communication Technology Research and Development Program of Institute for Information &amp; Communications Technology (ICT) Promotion Ministry of Science and ICT (2014-0-00230) and the Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education (2017R1D1A1B03034681).</p>
    </ack>
    <fn-group>
      <fn fn-type="conflict">
        <p>None declared.</p>
      </fn>
    </fn-group>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Memon</surname>
            <given-names>AG</given-names>
          </name>
          <name name-style="western">
            <surname>Naeem</surname>
            <given-names>Z</given-names>
          </name>
          <name name-style="western">
            <surname>Zaman</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Zahid</surname>
            <given-names>F</given-names>
          </name>
        </person-group>
        <article-title>Occupational health related concerns among surgeons</article-title>
        <source>Int J Health Sci (Qassim)</source>  
        <year>2016</year>  
        <month>04</month>  
        <volume>10</volume>  
        <issue>2</issue>  
        <fpage>279</fpage>  
        <lpage>91</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/27103909"/>
        </comment>  
        <pub-id pub-id-type="medline">27103909</pub-id>
        <pub-id pub-id-type="pmcid">PMC4825900</pub-id></nlm-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Babar-Craig</surname>
            <given-names>H</given-names>
          </name>
          <name name-style="western">
            <surname>Banfield</surname>
            <given-names>G</given-names>
          </name>
          <name name-style="western">
            <surname>Knight</surname>
            <given-names>J</given-names>
          </name>
        </person-group>
        <article-title>Prevalence of back and neck pain amongst ENT consultants: national survey</article-title>
        <source>J Laryngol Otol</source>  
        <year>2003</year>  
        <month>12</month>  
        <volume>117</volume>  
        <issue>12</issue>  
        <fpage>979</fpage>  
        <lpage>82</lpage>  
        <pub-id pub-id-type="doi">10.1258/002221503322683885</pub-id>
        <pub-id pub-id-type="medline">14738610</pub-id></nlm-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Soueid</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Oudit</surname>
            <given-names>D</given-names>
          </name>
          <name name-style="western">
            <surname>Thiagarajah</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Laitung</surname>
            <given-names>G</given-names>
          </name>
        </person-group>
        <article-title>The pain of surgery: pain experienced by surgeons while operating</article-title>
        <source>Int J Surg</source>  
        <year>2010</year>  
        <volume>8</volume>  
        <issue>2</issue>  
        <fpage>118</fpage>  
        <lpage>20</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:type="simple" xlink:href="https://linkinghub.elsevier.com/retrieve/pii/S1743-9191(09)00170-8"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1016/j.ijsu.2009.11.008</pub-id>
        <pub-id pub-id-type="medline">19944192</pub-id>
        <pub-id pub-id-type="pii">S1743-9191(09)00170-8</pub-id></nlm-citation>
      </ref>
      <ref id="ref4">
        <label>4</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Szeto</surname>
            <given-names>GPY</given-names>
          </name>
          <name name-style="western">
            <surname>Ho</surname>
            <given-names>P</given-names>
          </name>
          <name name-style="western">
            <surname>Ting</surname>
            <given-names>ACW</given-names>
          </name>
          <name name-style="western">
            <surname>Poon</surname>
            <given-names>JTC</given-names>
          </name>
          <name name-style="western">
            <surname>Cheng</surname>
            <given-names>SWK</given-names>
          </name>
          <name name-style="western">
            <surname>Tsang</surname>
            <given-names>RCC</given-names>
          </name>
        </person-group>
        <article-title>Work-related musculoskeletal symptoms in surgeons</article-title>
        <source>J Occup Rehabil</source>  
        <year>2009</year>  
        <month>06</month>  
        <volume>19</volume>  
        <issue>2</issue>  
        <fpage>175</fpage>  
        <lpage>84</lpage>  
        <pub-id pub-id-type="doi">10.1007/s10926-009-9176-1</pub-id>
        <pub-id pub-id-type="medline">19381790</pub-id></nlm-citation>
      </ref>
      <ref id="ref5">
        <label>5</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Mendez</surname>
            <given-names>BM</given-names>
          </name>
          <name name-style="western">
            <surname>Chiodo</surname>
            <given-names>MV</given-names>
          </name>
          <name name-style="western">
            <surname>Vandevender</surname>
            <given-names>D</given-names>
          </name>
          <name name-style="western">
            <surname>Patel</surname>
            <given-names>PA</given-names>
          </name>
        </person-group>
        <article-title>Heads-up 3D Microscopy: An Ergonomic and Educational Approach to Microsurgery</article-title>
        <source>Plast Reconstr Surg Glob Open</source>  
        <year>2016</year>  
        <month>05</month>  
        <volume>4</volume>  
        <issue>5</issue>  
        <fpage>e717</fpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:type="simple" xlink:href="http://europepmc.org/abstract/MED/27579241"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1097/GOX.0000000000000727</pub-id>
        <pub-id pub-id-type="medline">27579241</pub-id>
        <pub-id pub-id-type="pmcid">PMC4995703</pub-id></nlm-citation>
      </ref>
      <ref id="ref6">
        <label>6</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Keller</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>State</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Fuchs</surname>
            <given-names>H</given-names>
          </name>
        </person-group>
        <article-title>Head Mounted Displays for Medical Use</article-title>
        <source>J Display Technol</source>  
        <year>2008</year>  
        <month>12</month>  
        <volume>4</volume>  
        <issue>4</issue>  
        <fpage>468</fpage>  
        <lpage>472</lpage>  
        <pub-id pub-id-type="doi">10.1109/JDT.2008.2001577</pub-id></nlm-citation>
      </ref>
      <ref id="ref7">
        <label>7</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>van Lindert</surname>
            <given-names>EJ</given-names>
          </name>
          <name name-style="western">
            <surname>Grotenhuis</surname>
            <given-names>JA</given-names>
          </name>
          <name name-style="western">
            <surname>Beems</surname>
            <given-names>T</given-names>
          </name>
        </person-group>
        <article-title>The use of a head-mounted display for visualization in neuroendoscopy</article-title>
        <source>Comput Aided Surg</source>  
        <year>2004</year>  
        <volume>9</volume>  
        <issue>6</issue>  
        <fpage>251</fpage>  
        <lpage>6</lpage>  
        <pub-id pub-id-type="doi">10.3109/10929080500165476</pub-id>
        <pub-id pub-id-type="medline">16112975</pub-id>
        <pub-id pub-id-type="pii">L671070327415145</pub-id></nlm-citation>
      </ref>
      <ref id="ref8">
        <label>8</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Maithel</surname>
            <given-names>SK</given-names>
          </name>
          <name name-style="western">
            <surname>Villegas</surname>
            <given-names>L</given-names>
          </name>
          <name name-style="western">
            <surname>Stylopoulos</surname>
            <given-names>N</given-names>
          </name>
          <name name-style="western">
            <surname>Dawson</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Jones</surname>
            <given-names>DB</given-names>
          </name>
        </person-group>
        <article-title>Simulated laparoscopy using a head-mounted display vs traditional video monitor: an assessment of performance and muscle fatigue</article-title>
        <source>Surg Endosc</source>  
        <year>2005</year>  
        <month>03</month>  
        <volume>19</volume>  
        <issue>3</issue>  
        <fpage>406</fpage>  
        <lpage>11</lpage>  
        <pub-id pub-id-type="doi">10.1007/s00464-004-8177-6</pub-id>
        <pub-id pub-id-type="medline">15624063</pub-id></nlm-citation>
      </ref>
      <ref id="ref9">
        <label>9</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Minnich</surname>
            <given-names>DJ</given-names>
          </name>
          <name name-style="western">
            <surname>Schell</surname>
            <given-names>SR</given-names>
          </name>
        </person-group>
        <article-title>Evaluation of face-mounted binocular video display for laparoscopy: outcomes of psychometric skills testing and surgeon satisfaction</article-title>
        <source>J Laparoendosc Adv Surg Tech A</source>  
        <year>2003</year>  
        <month>10</month>  
        <volume>13</volume>  
        <issue>5</issue>  
        <fpage>333</fpage>  
        <lpage>8</lpage>  
        <pub-id pub-id-type="doi">10.1089/109264203769681754</pub-id>
        <pub-id pub-id-type="medline">14617395</pub-id></nlm-citation>
      </ref>
      <ref id="ref10">
        <label>10</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Prendergast</surname>
            <given-names>CJ</given-names>
          </name>
          <name name-style="western">
            <surname>Ryder</surname>
            <given-names>BA</given-names>
          </name>
          <name name-style="western">
            <surname>Abodeely</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Muratore</surname>
            <given-names>CS</given-names>
          </name>
          <name name-style="western">
            <surname>Crawford</surname>
            <given-names>GP</given-names>
          </name>
          <name name-style="western">
            <surname>Luks</surname>
            <given-names>FI</given-names>
          </name>
        </person-group>
        <article-title>Surgical performance with head-mounted displays in laparoscopic surgery</article-title>
        <source>J Laparoendosc Adv Surg Tech A</source>  
        <year>2009</year>  
        <month>04</month>  
        <volume>19 Suppl 1</volume>  
        <fpage>S237</fpage>  
        <lpage>40</lpage>  
        <pub-id pub-id-type="doi">10.1089/lap.2008.0142.supp</pub-id>
        <pub-id pub-id-type="medline">18999982</pub-id></nlm-citation>
      </ref>
      <ref id="ref11">
        <label>11</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Kihara</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>Fujii</surname>
            <given-names>Y</given-names>
          </name>
          <name name-style="western">
            <surname>Masuda</surname>
            <given-names>H</given-names>
          </name>
          <name name-style="western">
            <surname>Saito</surname>
            <given-names>K</given-names>
          </name>
          <name name-style="western">
            <surname>Koga</surname>
            <given-names>F</given-names>
          </name>
          <name name-style="western">
            <surname>Matsuoka</surname>
            <given-names>Y</given-names>
          </name>
          <name name-style="western">
            <surname>Numao</surname>
            <given-names>N</given-names>
          </name>
          <name name-style="western">
            <surname>Kojima</surname>
            <given-names>K</given-names>
          </name>
        </person-group>
        <article-title>New three-dimensional head-mounted display system, TMDU-S-3D system, for minimally invasive surgery application: procedures for gasless single-port radical nephrectomy</article-title>
        <source>Int J Urol</source>  
        <year>2012</year>  
        <month>09</month>  
        <volume>19</volume>  
        <issue>9</issue>  
        <fpage>886</fpage>  
        <lpage>9</lpage>  
        <comment>
          <ext-link xmlns:xlink="http://www.w3.org/1999/xlink" ext-link-type="uri" xlink:type="simple" xlink:href="https://doi.org/10.1111/j.1442-2042.2012.03044.x"/>
        </comment>  
        <pub-id pub-id-type="doi">10.1111/j.1442-2042.2012.03044.x</pub-id>
        <pub-id pub-id-type="medline">22587397</pub-id></nlm-citation>
      </ref>
      <ref id="ref12">
        <label>12</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Morisawa</surname>
            <given-names>T</given-names>
          </name>
          <name name-style="western">
            <surname>Kida</surname>
            <given-names>H</given-names>
          </name>
          <name name-style="western">
            <surname>Kusumi</surname>
            <given-names>F</given-names>
          </name>
          <name name-style="western">
            <surname>Okinaga</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Ohana</surname>
            <given-names>M</given-names>
          </name>
        </person-group>
        <article-title>Endoscopic Submucosal Dissection Using Head-mounted Display</article-title>
        <source>Gastroenterology</source>  
        <year>2015</year>  
        <month>08</month>  
        <volume>149</volume>  
        <issue>2</issue>  
        <fpage>290</fpage>  
        <lpage>1.e1</lpage>  
        <pub-id pub-id-type="doi">10.1053/j.gastro.2015.04.056</pub-id>
        <pub-id pub-id-type="medline">26055137</pub-id>
        <pub-id pub-id-type="pii">S0016-5085(15)00786-6</pub-id></nlm-citation>
      </ref>
      <ref id="ref13">
        <label>13</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Dutra-Medeiros</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Nascimento</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Henriques</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Barrão</surname>
            <given-names>S</given-names>
          </name>
          <name name-style="western">
            <surname>Fernandes-Fonseca</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Aguiar-Silva</surname>
            <given-names>N</given-names>
          </name>
          <name name-style="western">
            <surname>Moura-Coelho</surname>
            <given-names>N</given-names>
          </name>
          <name name-style="western">
            <surname>Ágoas</surname>
            <given-names>V</given-names>
          </name>
        </person-group>
        <article-title>Three-Dimensional Head-Mounted Display System for Ophthalmic Surgical Procedures</article-title>
        <source>Retina</source>  
        <year>2017</year>  
        <month>07</month>  
        <volume>37</volume>  
        <issue>7</issue>  
        <fpage>1411</fpage>  
        <lpage>1414</lpage>  
        <pub-id pub-id-type="doi">10.1097/IAE.0000000000001514</pub-id>
        <pub-id pub-id-type="medline">28098739</pub-id></nlm-citation>
      </ref>
      <ref id="ref14">
        <label>14</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Ramanathan</surname>
            <given-names>R</given-names>
          </name>
          <name name-style="western">
            <surname>Salamanca</surname>
            <given-names>JIM</given-names>
          </name>
          <name name-style="western">
            <surname>Mandhani</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Leung</surname>
            <given-names>RA</given-names>
          </name>
          <name name-style="western">
            <surname>Rao</surname>
            <given-names>SR</given-names>
          </name>
          <name name-style="western">
            <surname>Berryhill</surname>
            <given-names>R</given-names>
          </name>
          <name name-style="western">
            <surname>Tewari</surname>
            <given-names>A</given-names>
          </name>
        </person-group>
        <article-title>Does 3-Dimensional (3-D) visualization improve the quality of assistance during robotic radical prostatectomy?</article-title>
        <source>World J Urol</source>  
        <year>2009</year>  
        <month>02</month>  
        <volume>27</volume>  
        <issue>1</issue>  
        <fpage>95</fpage>  
        <lpage>9</lpage>  
        <pub-id pub-id-type="doi">10.1007/s00345-008-0325-5</pub-id>
        <pub-id pub-id-type="medline">18807048</pub-id></nlm-citation>
      </ref>
      <ref id="ref15">
        <label>15</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bhayani</surname>
            <given-names>SB</given-names>
          </name>
          <name name-style="western">
            <surname>Andriole</surname>
            <given-names>GL</given-names>
          </name>
        </person-group>
        <article-title>Three-Dimensional (3D) Vision: Does It Improve Laparoscopic Skills? An Assessment of a 3D Head-Mounted Visualization System</article-title>
        <source>Rev Urol</source>  
        <year>2005</year>  
        <volume>7</volume>  
        <issue>4</issue>  
        <fpage>211</fpage>  
        <lpage>4</lpage>  
        <pub-id pub-id-type="medline">16985832</pub-id>
        <pub-id pub-id-type="pmcid">PMC1477587</pub-id></nlm-citation>
      </ref>
      <ref id="ref16">
        <label>16</label>
        <nlm-citation citation-type="confproc">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Yoon</surname>
            <given-names>J</given-names>
          </name>
          <name name-style="western">
            <surname>Kim</surname>
            <given-names>H</given-names>
          </name>
          <name name-style="western">
            <surname>Kim</surname>
            <given-names>C</given-names>
          </name>
        </person-group>
        <article-title>Development of image error correction system for 3D optical microscope</article-title>
        <year>2015</year>  
        <conf-name>2015 Second International Conference on Computing Technology and Information Management (ICCTIM)</conf-name>
        <conf-date>21-23 April, 2015</conf-date>
        <conf-loc>Johor, Malaysia</conf-loc>
        <fpage>105</fpage>  
        <lpage>108</lpage> </nlm-citation>
      </ref>
      <ref id="ref17">
        <label>17</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Bay</surname>
            <given-names>H</given-names>
          </name>
          <name name-style="western">
            <surname>Ess</surname>
            <given-names>A</given-names>
          </name>
          <name name-style="western">
            <surname>Tuytelaars</surname>
            <given-names>T</given-names>
          </name>
          <name name-style="western">
            <surname>Van Gool</surname>
            <given-names>L</given-names>
          </name>
        </person-group>
        <article-title>Speeded-Up Robust Features (SURF)</article-title>
        <source>Computer Vision and Image Understanding</source>  
        <year>2008</year>  
        <month>6</month>  
        <volume>110</volume>  
        <issue>3</issue>  
        <fpage>346</fpage>  
        <lpage>359</lpage>  
        <pub-id pub-id-type="doi">10.1016/j.cviu.2007.09.014</pub-id></nlm-citation>
      </ref>
      <ref id="ref18">
        <label>18</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Hong</surname>
            <given-names>G</given-names>
          </name>
          <name name-style="western">
            <surname>Luo</surname>
            <given-names>M</given-names>
          </name>
          <name name-style="western">
            <surname>Rhodes</surname>
            <given-names>P</given-names>
          </name>
        </person-group>
        <article-title>A study of digital camera colorimetric characterization based on polynomial modeling</article-title>
        <source>Color Res Appl</source>  
        <year>2000</year>  
        <month>02</month>  
        <volume>26</volume>  
        <issue>1</issue>  
        <fpage>76</fpage>  
        <lpage>84</lpage>  
        <pub-id pub-id-type="doi">10.1002/1520-6378(200102)26:1&lt;76::AID-COL8&gt;3.0.CO;2-3</pub-id></nlm-citation>
      </ref>
      <ref id="ref19">
        <label>19</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Pointer</surname>
            <given-names>MR</given-names>
          </name>
          <name name-style="western">
            <surname>Attridge</surname>
            <given-names>GG</given-names>
          </name>
          <name name-style="western">
            <surname>Jacobson</surname>
            <given-names>RE</given-names>
          </name>
        </person-group>
        <article-title>Practical camera characterization for colour measurement</article-title>
        <source>The Imaging Science Journal</source>  
        <year>2016</year>  
        <month>10</month>  
        <day>06</day>  
        <volume>49</volume>  
        <issue>2</issue>  
        <fpage>63</fpage>  
        <lpage>80</lpage>  
        <pub-id pub-id-type="doi">10.1080/13682199.2001.11784369</pub-id></nlm-citation>
      </ref>
      <ref id="ref20">
        <label>20</label>
        <nlm-citation citation-type="journal">
        <person-group person-group-type="author">
          <name name-style="western">
            <surname>Cheng</surname>
            <given-names>D</given-names>
          </name>
          <name name-style="western">
            <surname>Wang</surname>
            <given-names>Y</given-names>
          </name>
          <name name-style="western">
            <surname>Xu</surname>
            <given-names>C</given-names>
          </name>
          <name name-style="western">
            <surname>Song</surname>
            <given-names>W</given-names>
          </name>
          <name name-style="western">
            <surname>Jin</surname>
            <given-names>G</given-names>
          </name>
        </person-group>
        <article-title>Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics</article-title>
        <source>Opt Express</source>  
        <year>2014</year>  
        <month>08</month>  
        <day>25</day>  
        <volume>22</volume>  
        <issue>17</issue>  
        <fpage>20705</fpage>  
        <lpage>19</lpage>  
        <pub-id pub-id-type="doi">10.1364/OE.22.020705</pub-id>
        <pub-id pub-id-type="medline">25321274</pub-id>
        <pub-id pub-id-type="pii">299627</pub-id></nlm-citation>
      </ref>
    </ref-list>
  </back>
</article>
