<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Mhealth Uhealth</journal-id><journal-id journal-id-type="publisher-id">mhealth</journal-id><journal-id journal-id-type="index">13</journal-id><journal-title>JMIR mHealth and uHealth</journal-title><abbrev-journal-title>JMIR Mhealth Uhealth</abbrev-journal-title><issn pub-type="epub">2291-5222</issn></journal-meta><article-meta><article-id pub-id-type="publisher-id">44147</article-id><article-id pub-id-type="doi">10.2196/44147</article-id><title-group><article-title>Blood Pressure Measurement Based on the Camera and Inertial Measurement Unit of a Smartphone: Instrument Validation Study</article-title></title-group><contrib-group><contrib contrib-type="author"><name name-style="western"><surname>Yoon</surname><given-names>Yong-Hoon</given-names></name><degrees>MD, DPhil</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Kim</surname><given-names>Jongin</given-names></name><degrees>DPhil</degrees><xref ref-type="aff" rid="aff2">2</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Lee</surname><given-names>Kwang Jin</given-names></name><degrees>DPhil</degrees><xref ref-type="aff" rid="aff2">2</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Cho</surname><given-names>Dongrae</given-names></name><xref ref-type="aff" rid="aff2">2</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Oh</surname><given-names>Jin Kyung</given-names></name><degrees>MD, DPhil</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Kim</surname><given-names>Minsu</given-names></name><degrees>MD, DPhil</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Roh</surname><given-names>Jae-Hyung</given-names></name><degrees>MD, DPhil</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Park</surname><given-names>Hyun Woong</given-names></name><degrees>MD, DPhil</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>Lee</surname><given-names>Jae-Hwan</given-names></name><degrees>MD, DPhil</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib></contrib-group><aff id="aff1"><institution>Chungnam National University Sejong Hospital</institution>, <addr-line>Sejong-Si</addr-line>, <country>Republic of Korea</country></aff><aff id="aff2"><institution>Deepmedi Research Institute of Technology</institution>, <addr-line>Seoul</addr-line>, <country>Republic of Korea</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Buis</surname><given-names>Lorraine</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Logan</surname><given-names>Alexander</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Merid</surname><given-names>Beza</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Melville</surname><given-names>Sarah</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Jae-Hwan Lee, MD, DPhil<email>myheart@cnu.ac.kr</email></corresp></author-notes><pub-date pub-type="collection"><year>2023</year></pub-date><pub-date pub-type="epub"><day>8</day><month>9</month><year>2023</year></pub-date><volume>11</volume><elocation-id>e44147</elocation-id><history><date date-type="received"><day>08</day><month>11</month><year>2022</year></date><date date-type="rev-recd"><day>13</day><month>04</month><year>2023</year></date><date date-type="accepted"><day>21</day><month>07</month><year>2023</year></date></history><copyright-statement>&#x00A9;Yong-Hoon Yoon, Jongin Kim, Kwang Jin Lee, Dongrae Cho, Jin Kyung Oh, Minsu Kim, Jae-Hyung Roh, Hyun Woong Park, Jae-Hwan Lee. Originally published in JMIR mHealth and uHealth (<ext-link ext-link-type="uri" xlink:href="https://mhealth.jmir.org">https://mhealth.jmir.org</ext-link>), 8.9.2023. </copyright-statement><copyright-year>2023</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://mhealth.jmir.org/">https://mhealth.jmir.org/</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://mhealth.jmir.org/2023/1/e44147"/><abstract><sec><title>Background</title><p>Even though several mobile apps that can measure blood pressure have been developed, the data about the accuracy of these apps are limited.</p></sec><sec><title>Objective</title><p>We assessed the accuracy of AlwaysBP (test) in blood pressure measurement compared with the standard, cuff-based, manual method of brachial blood pressure measurement (reference).</p></sec><sec sec-type="methods"><title>Methods</title><p>AlwaysBP is a smartphone software that estimates systolic blood pressure (SBP) and diastolic blood pressure (DBP) based on pulse transit time (PTT). PTT was calculated with a finger photoplethysmogram and seismocardiogram using, respectively, the camera and inertial measurement unit sensor of a commercially available smartphone. After calculating PTT, SBP and DBP were estimated via the Bramwell-Hill and Moens-Korteweg equations. A calibration process was carried out 3 times for each participant to determine the input parameters of the equations. This study was conducted from March to August 2021 at Chungnam National University Sejong Hospital with 87 participants aged between 19 and 70 years who met specific conditions. The primary analysis aimed to evaluate the accuracy of the test method compared with the reference method for the entire study population. The secondary analysis was performed to confirm the stability of the test method for up to 4 weeks in 15 participants. At enrollment, gender, arm circumference, and blood pressure distribution were considered according to current guidelines.</p></sec><sec sec-type="results"><title>Results</title><p>Among the 87 study participants, 45 (52%) individuals were male, and the average age was 35.6 (SD 10.4) years. Hypertension was diagnosed in 14 (16%) participants before this study. The mean test and reference SBPs were 120.0 (SD 18.8) and 118.7 (SD 20.2) mm Hg, respectively (difference: mean 1.2, SD 7.1 mm Hg). The absolute differences between the test and reference SBPs were &#x003C;5, &#x003C;10, and &#x003C;15 mm Hg in 57.5% (150/261), 84.3% (220/261 ), and 94.6% (247/261) of measurements. The mean test and reference DBPs were 80.1 (SD 12.6) and 81.1 (SD 14.4) mm Hg, respectively (difference: mean &#x2212;1.0, SD 6.0 mm Hg). The absolute differences between the test and reference DBPs were &#x003C;5, &#x003C;10, and &#x003C;15 mm Hg in 75.5% (197/261), 93.9% (245/261), and 97.3% (254/261) of measurements, respectively. The secondary analysis showed that after 4 weeks, the differences between SBP and DBP were 0.1 (SD 8.8) and &#x2212;2.4 (SD 7.6) mm Hg, respectively.</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>AlwaysBP exhibited acceptable accuracy in SBP and DBP measurement compared with the standard measurement method, according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization protocol criteria. However, further validation studies with a specific validation protocol designed for cuffless blood pressure measuring devices are required to assess clinical accuracy. This technology can be easily applied in everyday life and may improve the general population&#x2019;s awareness of hypertension, thus helping to control it.</p></sec></abstract><kwd-group><kwd>blood pressure</kwd><kwd>camera</kwd><kwd>cuffless</kwd><kwd>inertial measurement unit</kwd><kwd>smartphone software</kwd><kwd>cardiovascular</kwd><kwd>hypertension</kwd><kwd>smartphone</kwd><kwd>measure</kwd><kwd>accuracy</kwd><kwd>accurate</kwd><kwd>software</kwd><kwd>mHealth</kwd><kwd>mobile health</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>Hypertension is an established major risk factor for various cardiovascular diseases and mortality [<xref ref-type="bibr" rid="ref1">1</xref>]. Significant efforts have been made to understand the epidemiology, pathophysiology, and associated risks of hypertension to reduce premature cardiovascular morbidity and mortality [<xref ref-type="bibr" rid="ref2">2</xref>,<xref ref-type="bibr" rid="ref3">3</xref>]. Thus, the proportion of patients with well-controlled hypertension has increased over the past few decades [<xref ref-type="bibr" rid="ref4">4</xref>]. High blood pressure can be easily detected at home or in public health centers and is often effectively treated with medications. However, there is a high rate of unawareness of hypertension for a large portion of the total population with hypertension, and the blood pressure control rate of patients with hypertension, especially in low-income countries, remains unsatisfactory. For these people, the early detection and proper management of hypertension are important to prevent future cardiovascular disease, which depends on the accuracy and accessibility of blood pressure measurement methods.</p><p>To improve the accessibility of blood pressure measurement, many new devices are being developed for this purpose that are comparable to the conventional, cuff-based, manual method or oscillometric blood pressure measurement devices. Cuffless devices include wristbands, rings, patch systems, and smartphone software; these devices have exhibited acceptable accuracy when compared with conventional blood pressure measurements [<xref ref-type="bibr" rid="ref5">5</xref>-<xref ref-type="bibr" rid="ref9">9</xref>]. The principle of cuffless blood pressure measurement is mainly based on the analysis of the pulse transit time (PTT) or photoplethysmography waveform to estimate blood pressure via a linear regression model or machine learning techniques. These methods are easier to use in daily life, and there is no cuff-induced discomfort during their use. However, most new technologies require photoplethysmograms or other sensors to detect the signal waveforms, which may limit their widespread use because of the cost associated with the additional equipment that is required.</p><p>The number of smartphone users has increased worldwide, and many people in high-income and low-income countries use them [<xref ref-type="bibr" rid="ref10">10</xref>]. Most smartphones are equipped with a camera, image sensor, and inertial measurement unit (IMU) sensor; thus, attempts have been made to measure biosignals by using these sensors [<xref ref-type="bibr" rid="ref11">11</xref>]. If heart movements can be detected by using the IMU sensor of a smartphone and by placing it on an individual&#x2019;s chest, and if the pulse of the fingertip can be acquired by using the camera of a mobile phone, then the smartphone may be used to estimate the PTT. Furthermore, if blood pressure can be estimated through the PTT obtained by using a smartphone, then blood pressure can be monitored with a smartphone without the use of additional equipment. Therefore, this study assessed a smartphone-based software that estimates blood pressure by using the PTT obtained through the smartphone.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Study Design and Participants</title><p>This study was conducted at Chungnam National University Sejong Hospital from March 2021 to August 2021. The enrollment targeted adults aged between 19 and 70 years. Those who met the following conditions were excluded: (1) individuals who were unable to use the test or reference blood pressure measurement device for up to 30 minutes in a sitting position (2) and individuals who had a history of cardiac arrhythmias or peripheral vascular disease. We determined the number of participants according to a validation guideline, which states that at least 85 patients are required for an Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) validation study [<xref ref-type="bibr" rid="ref12">12</xref>]. At enrollment, gender, arm circumference, and blood pressure distribution were also considered according to the AAMI/ESH/ISO guideline [<xref ref-type="bibr" rid="ref12">12</xref>,<xref ref-type="bibr" rid="ref13">13</xref>].</p><p>The test device, AlwaysBP (Deepmedi Inc), is a smartphone software that estimates a person&#x2019;s systolic blood pressure (SBP) and diastolic blood pressure (DBP) based on the PTT. The blood pressure estimation model was designed to include the following two steps: (1) calculation of the PTT by using seismocardiography and photoplethysmography via the test device and (2) input of the acquired PTT into the blood pressure estimating equations (<xref ref-type="fig" rid="figure1">Figure 1</xref>). PTT was calculated as the time interval between the aortic valve opening on the seismocardiogram, as detected by the IMU sensor, and the onset of the photoplethysmography waveform on the index finger, as detected by the camera of the smartphone. These seismocardiography and photoplethysmography signals were acquired for 20 seconds in each measurement. An infinite impulse response band-pass filter was used for seismocardiography (5-45 Hz) and photoplethysmography (0.8-8 Hz) to denoise the raw signal. The filtered seismocardiography signal was then ensemble-averaged after segmenting the interval between the onset of each wave of the photoplethysmography signal and 450 milliseconds after the onset. This ensemble-averaged signal was input into a deep neural network model to determine the aortic valve opening time accurately. The manufacturer pretrained this deep neural network model, and the same model was used for all participants. After PTT calculation, SBP and DBP were estimated with the equations introduced by Bramwell-Hill and Moens-Korteweg, as follows [<xref ref-type="bibr" rid="ref14">14</xref>]:</p><disp-formula><graphic xlink:href="mhealth_v11i1e44147_fig04.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/><label>(1)</label></disp-formula><disp-formula id="E2"><graphic xlink:href="mhealth_v11i1e44147_fig05.png" alt-version="no" mimetype="image" position="float" xlink:type="simple"/><label>(2)</label></disp-formula><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>Mechanism and application of the test device. AO: aortic opening; DNN: deep neural network; IMU: inertial measurement unit; PPG: photoplethysmography; PTT: pulse transit time.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v11i1e44147_fig01.png"/></fig><p>To determine the input parameters of the equations, a calibration process was carried out 3 times for each participant [<xref ref-type="bibr" rid="ref14">14</xref>]. The PTT was measured by using the test device during calibration, and SBP and DBP were also measured simultaneously by using the cuff-based reference device. Pulse pressure (PP) and mean blood pressure (MBP) were calculated based on the SBP and DBP values. Based on the first and second calibration processes, the average PTT value obtained by the test device was entered as PTT<sub>0</sub>, and the average PP and MBP measured by cuff-based blood pressure measurement device were entered as PP<sub>0</sub> and MBP<sub>0</sub>, respectively. The PTT value obtained from the third calibration was input as the PTT of the formulas, and SBP and DBP values were input as the SBP and DBP, respectively; moreover, the &#x03B3; value was updated according to the results of the calculated equations (before the correction, &#x03B3; was determined to be 0.031 for individuals younger than 40 years and 0.09 for those older than 40 years) [<xref ref-type="bibr" rid="ref15">15</xref>]. After the correction was completed, when measuring blood pressure for the primary analysis, the averages of the MBP, PP, and PTT values from the three calibration processes were input as MBP<sub>0</sub>, PP<sub>0</sub>, and PTT<sub>0</sub>, respectively, and the &#x03B3; obtained from the third calibration was used in the equations. This equation model was implemented in the AlwaysBP app and used to measure blood pressure at the initial visit and at follow-up. The test blood pressure measurement software was installed and used in a Galaxy S10 smartphone (Samsung Electronics) throughout this study. The test software has yet to be released on the app market for commercial use.</p></sec><sec id="s2-2"><title>Data Acquisition and Blood Pressure Measurements</title><p>The basic demographics, including past medical history, comorbidities, and drug use, of the participants were assessed through an interview with the physician and recorded on a dedicated electronic case reporting form. The participants sat in a comfortable position for at least 5 minutes before measuring blood pressure. During the blood pressure measurement, the participant&#x2019;s back and arms were supported, their left arm was placed at heart level, their legs were not crossed, and their feet were placed flat on the floor. Dialogue and other interferences were prohibited throughout the measurement. Calibration of the test device was performed just before the measurement of the blood pressure.</p><p>The test blood pressure was defined as the blood pressure value measured by the test device (AlwaysBP), and the reference blood pressure was defined as the blood pressure value measured by the reference blood pressure device (InBody). The reference SBP and DBP were measured, using the participant&#x2019;s left arm, by 2 trained nurses who were blind to each other&#x2019;s readings. A double-headed stethoscope (Y-tube) was used for the simultaneous auscultation of the brachial pulse, and the blood pressures at the first and fifth Korotkoff sound were recorded as SBP and DBP, respectively. The average blood pressure values measured by the two observers were considered the reference blood pressures for the analysis. The test blood pressure was measured simultaneously with the reference blood pressure. The participant&#x2019;s right hand held the test device, and the index finger was positioned to cover the camera lens on the back of the smartphone to obtain the finger photoplethysmography signal. Concomitantly, the seismocardiography signal was obtained by placing the front of the smartphone on the participant&#x2019;s anterior chest wall. This position was maintained for 20 seconds, and if the participant&#x2019;s position was inadequate for proceeding with the study or blood pressure measurement, the research personnel advised the participant to return to the correct position. If an error occurred because of the poor signal quality of the test blood pressure device resulting from the insufficient color change of the finger to red (a result of the LED light being below a predetermined threshold), blood pressure measurement was attempted again until the error did not occur.</p></sec><sec id="s2-3"><title>Study Protocol</title><p>This study consisted of 2 parts (<xref ref-type="fig" rid="figure2">Figure 2</xref>). The primary analysis aimed to evaluate the accuracy of the test device compared with the reference device for the entire study population (N=87). In turn, the secondary analysis was performed to confirm the stability of the test device for up to 4 weeks after the initial calibration and blood pressure measurement.</p><fig position="float" id="figure2"><label>Figure 2.</label><caption><p>Study flowchart. BP: blood pressure.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v11i1e44147_fig02.png"/></fig><p>For the primary analysis, blood pressure was measured 3 times for each participant after individualized calibration. Calibration was performed by entering the measured reference blood pressure value into the test device after applying the test and the reference devices at the same time. This process was performed 3 times consecutively, without a break. Afterward, 5 minutes of rest were allowed after completion of the calibration. Subsequently, blood pressure was measured 3 times per participant, with an interval of 5 minutes for resting. As a result, a total of 261 pairs of test-reference blood pressure sets from 87 participants were obtained for SBP and DBP, respectively.</p><p>Blood pressure was measured and recorded weekly for 4 weeks in 15 participants who were initially enrolled in this study to investigate the stability of the test device over time. Blood pressure measurements performed during the follow-up were carried out identically to the initial blood pressure measurements, with the exception that no calibration was performed.</p></sec><sec id="s2-4"><title>Statistical Analysis</title><p>Baseline characteristics were expressed as percentages for categorical variables and as means with SDs for continuous variables. Differences between test and reference blood pressure values in the primary and secondary analyses were expressed as means and SDs. To evaluate the correlation between the test and reference blood pressures, the <italic>P</italic> value and Pearson correlation coefficient (<italic>r</italic>) were calculated. Bland-Altman plots were generated to compare the distribution of differences in SBP and DBP between the test and reference devices. All reported <italic>P</italic> values were 2-sided, and significance was set at <italic>P</italic>&#x003C;.05. All statistical analyses were performed by using R software (version 4.1.1.; R Foundation for Statistical Computing).</p></sec><sec id="s2-5"><title>Ethics Approval</title><p>All participants participated voluntarily in this study and provided written informed consent. The study protocol was approved by the Institutional Review Committee of Chungnam National University Sejong Hospital (approval number: 2020-10-023). This study was conducted in accordance with the relevant guidelines and regulations.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><sec id="s3-1"><title>Baseline Characteristics</title><p>Among the 87 study participants, 45 (52%) individuals were male, and the average age was 35.6 (SD 10.4) years. The mean height and weight were 168.2 (SD 8.1) cm and 75.2 (SD 17.9) kg, respectively. Further, 14 (16%) participants were diagnosed with hypertension and were taking antihypertensive drugs prior to enrollment. The most used drug to manage hypertension was an angiotensin II receptor blocker. The mean screening SBP and DBP were 134.2 (SD 20.3) mm Hg and 82.8 (SD 15.2) mm Hg, respectively (<xref ref-type="table" rid="table1">Table 1</xref>).</p><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Baseline characteristics of the participants (N=87).</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom" colspan="2">Characteristics</td><td align="left" valign="bottom">Value</td></tr></thead><tbody><tr><td align="left" valign="top" colspan="2">Age (years), mean (SD)</td><td align="left" valign="top">35.6 (10.4)</td></tr><tr><td align="left" valign="top" colspan="2">Men, n (%)</td><td align="left" valign="top">45 (52)</td></tr><tr><td align="left" valign="top" colspan="2">Height (cm), mean (SD)</td><td align="left" valign="top">168.2 (8.1)</td></tr><tr><td align="left" valign="top" colspan="2">Weight (kg), mean (SD)</td><td align="left" valign="top">75.2 (17.9)</td></tr><tr><td align="left" valign="top" colspan="2">Arm circumference (cm), mean (SD)</td><td align="left" valign="top">30.0 (3.8)</td></tr><tr><td align="left" valign="top" colspan="2">Hypertension with medications, n (%)</td><td align="left" valign="top">14 (16)</td></tr><tr><td align="left" valign="top" colspan="2">Angiotensin II receptor blockers, n (%)</td><td align="left" valign="top">11 (13)</td></tr><tr><td align="left" valign="top" colspan="2">Beta-blocker, n (%)</td><td align="left" valign="top">3 (3)</td></tr><tr><td align="left" valign="top" colspan="2">Calcium channel blocker, n (%)</td><td align="left" valign="top">9 (10)</td></tr><tr><td align="left" valign="top" colspan="2">Diuretics, n (%)</td><td align="left" valign="top">3 (3)</td></tr><tr><td align="left" valign="top" colspan="2">Diabetes mellitus, n (%)</td><td align="left" valign="top">3 (3)</td></tr><tr><td align="left" valign="top" colspan="2">Dyslipidemia, n (%)</td><td align="left" valign="top">5 (6)</td></tr><tr><td align="left" valign="top" colspan="3"><bold>Blood pressure at screening</bold></td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">SBP<sup><xref ref-type="table-fn" rid="table1fn1">a</xref></sup> (mm Hg), mean (SD)</td><td align="left" valign="top">134.2 (20.3)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">DBP<sup><xref ref-type="table-fn" rid="table1fn2">b</xref></sup> (mm Hg), mean (SD)</td><td align="left" valign="top">82.8 (15.2)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">HR<sup><xref ref-type="table-fn" rid="table1fn3">c</xref></sup> (beats per minute), mean (SD)</td><td align="left" valign="top">81.2 (10.4)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">SBP&#x2265;160 mm Hg, n (%)</td><td align="left" valign="top">9 (10)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">DBP&#x2265;100 mm Hg, n (%)</td><td align="left" valign="top">14 (16)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">SBP&#x2264;110 mm Hg, n (%)</td><td align="left" valign="top">9 (10)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">DBP &#x2264;70 mm Hg, n (%)</td><td align="left" valign="top">17 (20)</td></tr></tbody></table><table-wrap-foot><fn id="table1fn1"><p><sup>a</sup>SBP: systolic blood pressure.</p></fn><fn id="table1fn2"><p><sup>b</sup>DBP: diastolic blood pressure.</p></fn><fn id="table1fn3"><p><sup>c</sup>HR: heart rate.</p></fn></table-wrap-foot></table-wrap></sec><sec id="s3-2"><title>Primary Analysis</title><p>The mean test SBP was 120.0 (SD 18.8) mm Hg, and the mean reference SBP was 118.7 (SD 20.2) mm Hg (<xref ref-type="table" rid="table2">Table 2</xref>). The difference between the test and reference blood pressures was 1.2 (SD 7.1) mm Hg. The absolute differences between the test and baseline SBPs were &#x003C;5, &#x003C;10, and &#x003C;15 mm Hg in 57.5% (150/261), 84.3% (220/261), and 94.6% (247/261) of the measurements, respectively (<xref ref-type="fig" rid="figure3">Figure 3</xref>). In the Bland-Altman plot, of the 261 measurements, 15 (5.7%) were outside 2 SDs of the differences between test and reference SBPs. The DBP values of the test and reference devices were 80.1 (SD 12.6) mm Hg and 81.1 (SD 14.4) mm Hg, respectively. The difference was &#x2212;1.0 (SD 6.0) mm Hg, but the difference became progressively more pronounced at higher blood pressure levels. The absolute differences between the test and the reference DBPs were &#x003C;5, &#x003C;10, and &#x003C;15 mm Hg in 75.5% (197/261), 93.9% (245/261), and 97.3% (254/261) of the measurements. In the Bland-Altman plot, of the 261 measurements, 10 (3.8%) were outside 2 SDs of the differences, mostly for high blood pressure values.</p><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Differences between the test and reference blood pressures among 87 participants (261 measurement pairs in the primary analysis).</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom" colspan="2"/><td align="left" valign="top">SBP<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup>, mm Hg</td><td align="left" valign="top">DBP<sup><xref ref-type="table-fn" rid="table2fn2">b</xref></sup>, mm Hg</td><td align="left" valign="top">HR<sup><xref ref-type="table-fn" rid="table2fn3">c</xref></sup>, beats per minute</td></tr></thead><tbody><tr><td align="left" valign="top" colspan="2">Test device, mean (SD)</td><td align="left" valign="top">120.0 (18.8)</td><td align="left" valign="top">80.1 (12.6)</td><td align="left" valign="top">75.2 (10.4)</td></tr><tr><td align="left" valign="top" colspan="2">Reference device, mean (SD)</td><td align="left" valign="top">118.7 (20.2)</td><td align="left" valign="top">81.1 (14.4)</td><td align="left" valign="top">75.4 (10.1)</td></tr><tr><td align="left" valign="top" colspan="2">Difference, mean (SD)</td><td align="left" valign="top">1.2 (7.1)</td><td align="left" valign="top">&#x2212;1.0 (6.0)</td><td align="left" valign="top">&#x2212;0.2 (6.9)</td></tr><tr><td align="left" valign="top" colspan="5"><bold>Coefficient of variation for each participant, %</bold></td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">Test device</td><td align="left" valign="top">1.3</td><td align="left" valign="top">0.4</td><td align="left" valign="top">4.9</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">Reference device</td><td align="left" valign="top">3.1</td><td align="left" valign="top">3.2</td><td align="left" valign="top">4</td></tr></tbody></table><table-wrap-foot><fn id="table2fn1"><p><sup>a</sup>SBP: systolic blood pressure.</p></fn><fn id="table2fn2"><p><sup>b</sup>DBP: diastolic blood pressure.</p></fn><fn id="table2fn3"><p><sup>c</sup>HR: heart rate.</p></fn></table-wrap-foot></table-wrap><fig position="float" id="figure3"><label>Figure 3.</label><caption><p>Bland-Altman plots of the SBPs and DBPs measured using the test and reference devices. (A) Bland-Altman plot of the test and reference SBPs. (B) Bland-Altman plot of the test and reference DBPs. DBP: diastolic blood pressure; SBP: systolic blood pressure.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v11i1e44147_fig03.png"/></fig></sec><sec id="s3-3"><title>Secondary Analysis</title><p><xref ref-type="table" rid="table3">Table 3</xref> lists the results of the follow-up measurements for the test and reference blood pressure values in 15 participants, which were used in the secondary analysis. The differences at the baseline were 1.7 (SD 6.9) mm Hg (<italic>P</italic>=.10) and &#x2212;2.0 (SD 5.3) mm Hg (<italic>P</italic>=.01) for SBP and DBP, respectively. After 4 weeks, the differences between SBP and DBP were 0.1 (SD 8.8) mm Hg (<italic>P</italic>=.96) and &#x2212;2.4 (SD 7.6) mm Hg (<italic>P</italic>=.04), respectively.</p><table-wrap id="t3" position="float"><label>Table 3.</label><caption><p>Differences between the test and reference blood pressures among 15 participants during the 4-week follow-up (45 measurement pairs per week in the secondary analysis).</p></caption><table id="table3" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom" colspan="2"/><td align="left" valign="top">Baseline</td><td align="left" valign="top">1 week</td><td align="left" valign="top">2 weeks</td><td align="left" valign="top">3 weeks</td><td align="left" valign="top">4 weeks</td></tr></thead><tbody><tr><td align="left" valign="top" colspan="7"><bold>SBP<sup><xref ref-type="table-fn" rid="table3fn1">a</xref></sup></bold></td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">Difference (mm Hg), mean (SD)</td><td align="left" valign="top">1.7 (6.9)</td><td align="left" valign="top">1.1 (6.8)</td><td align="left" valign="top">1.0 (7.6)</td><td align="left" valign="top">1.2 (8.7)</td><td align="left" valign="top">0.1 (8.8)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top"><italic>P</italic> value</td><td align="left" valign="top">.10</td><td align="left" valign="top">.31</td><td align="left" valign="top">.36</td><td align="left" valign="top">.37</td><td align="left" valign="top">.96</td></tr><tr><td align="left" valign="top" colspan="7"><bold>DBP<sup><xref ref-type="table-fn" rid="table3fn2">b</xref></sup></bold></td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">Difference (mm Hg), mean (SD)</td><td align="left" valign="top">&#x2212;2.0 (5.3)</td><td align="left" valign="top">&#x2212;1.6 (7.5)</td><td align="left" valign="top">&#x2212;3.2 (6.8)</td><td align="left" valign="top">0 (8.1)</td><td align="left" valign="top">&#x2212;2.4 (7.6)</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top"><italic>P</italic> value</td><td align="left" valign="top">.01</td><td align="left" valign="top">.15</td><td align="left" valign="top">.003</td><td align="left" valign="top">.97</td><td align="left" valign="top">.04</td></tr></tbody></table><table-wrap-foot><fn id="table3fn1"><p><sup>a</sup>SBP: systolic blood pressure.</p></fn><fn id="table3fn2"><p><sup>b</sup>DBP: diastolic blood pressure.</p></fn></table-wrap-foot></table-wrap></sec></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><sec id="s4-1"><title>Principal Findings</title><p>This study assessed the accuracy of a smartphone-based blood pressure measurement software (AlwaysBP) compared with the standard, cuff-based, manual method of brachial blood pressure measurement. Our results revealed that the test device showed acceptable accuracy for both SBP and DBP, and the difference between the test and reference SBP values was stable over the 1-month follow-up. The DBP values of the study device were not stable for 1 month.</p><p>The development of various cuffless blood pressure monitors has allowed for the measurement of blood pressure easily and comfortably. Such devices are expected to improve the penetration rate of blood pressure measurements, which is very important for lowering the rates of hypertension unawareness and uncontrolled hypertension after diagnosis. Several smart devices that can measure blood pressure without the use of a cuff have been developed. The most commercially available devices are smartwatch devices, which work mainly by acquiring photoplethysmography signals and estimating blood pressure via a machine learning algorithm based on these signals or PTT calculation [<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref7">7</xref>,<xref ref-type="bibr" rid="ref9">9</xref>,<xref ref-type="bibr" rid="ref15">15</xref>,<xref ref-type="bibr" rid="ref16">16</xref>]. The greatest advantage of smart devices is their ability to measure blood pressure continuously without interference; as such, they can be used to monitor blood pressure during rest, work, and exercise. In addition, they facilitate 24-hour ambulatory blood pressure monitoring by analyzing the trend and pattern of blood pressure change over 24 hours. Although controversies remain regarding their accuracy, they represent good alternatives to cuff-based, 24-hour ambulatory blood pressure monitoring if their accuracy is improved. Devices that measure blood pressure by using only a smartphone, without additional devices, have also been developed. With OptiBP (Biospectal), the photoplethysmography signal of the finger is measured by using a smartphone camera, and a pretrained deep learning model is used to estimate blood pressure based on the photoplethysmography signal [<xref ref-type="bibr" rid="ref6">6</xref>,<xref ref-type="bibr" rid="ref17">17</xref>]. Similar to the test device used in our study, the OptiBP software does not require an additional device; thus, it has the advantage of significantly improving the accessibility to blood pressure measurement.</p><p>In our study, the test device estimated SBP and DBP based on the PTT. The advantage of PTT-based blood pressure measurement over photoplethysmography analysis&#x2013;based blood pressure estimation has not been elucidated fully. However, there is a huge body of evidence that PTT is associated with blood pressure [<xref ref-type="bibr" rid="ref18">18</xref>-<xref ref-type="bibr" rid="ref20">20</xref>]. Moreover, the PTT can be used to assess vascular stiffness, arterial atherosclerosis, and the risk of future cardiovascular events [<xref ref-type="bibr" rid="ref21">21</xref>]. The software system used in our study does not require additional devices to measure both photoplethysmography signals and cardiac signals for PTT calculation. Moreover, because the AlwaysBP software collects photoplethysmography and seismocardiography signals simultaneously, it may detect an abnormal heart state more accurately than other devices that use photoplethysmography alone [<xref ref-type="bibr" rid="ref22">22</xref>]. Therefore, this software may play a role in improving the early detection of hypertension and arterial stiffness and in the prediction of cardiovascular events among the general population.</p><p>The existing blood pressure measuring devices requiring calibration also have limitations and therefore need to be improved. Changes in blood pressure within an individual are not usually considered in calibration and testing. Thus, there have been debates regarding the problems in validating cuffless blood pressure measuring devices that require calibration, because the time between calibration and testing is insufficient to account for individual differences in blood pressure [<xref ref-type="bibr" rid="ref23">23</xref>]. Our system also relies on a single individualized calibration, which may not be suitable for longtime use. Calibration was done to calculate &#x03B3; in the equations, and this value can be affected by age, sex, height, and vascular stiffness. The single-calibration results of the initial measurements were used for a long time. Even though the differences in SBP values between the test and reference devices among 15 participants over 1 month showed satisfactory results, the SD tended to become more prominent at follow-up. Additionally, DBP values were not stable during follow-up in our study population. Our results showed that accuracy may decrease over time, suggesting that a regular calibration process for long-term users may be necessary. This decrease in accuracy may have been due to changes in physiological properties, such as vascular stiffness and atherosclerosis, that vary at different rates in individuals over time. There will also be issues about the necessity of regular calibration and how often those calibrations will be needed for accurate blood pressure measurements. Ultimately, a calibration-free system is needed, but the development of calibration-free devices is still ongoing [<xref ref-type="bibr" rid="ref24">24</xref>]. To minimize the calibration issues, new devices that can be used without calibration should be developed. Moreover, the test DBPs showed relatively poor correlations at high blood pressures in this study, although the reasons underlying this finding are unclear. PTT calculation via smartphones is different from conventional PTT calculation, which involves electrocardiographic and photoplethysmographic sensors that are used in clinical practice and have higher resolutions. The inherent limitations of using a smartphone-only blood pressure measurement system result in potential accuracy issues, rendering such systems inferior in accuracy when compared to other smart devices, such as smartwatches with electrocardiographic and photoplethysmographic sensors. Further, we used a set of commonly used equations for calculating blood pressure with PTT. This equation set may not have been fit for our data, which were acquired via smartphones. Therefore, additional studies are needed, and an update of the algorithm may be necessary.</p><p>Due to the inherent features exhibited by cuffless blood pressure measuring devices, it is imperative to establish more specialized criteria for validating such products [<xref ref-type="bibr" rid="ref25">25</xref>]. The existing criteria cannot account for the capability of these devices to accurately monitor blood pressure fluctuations in response to positional changes, physical activity, emotional stress, and prolonged periods, which can significantly influence individuals&#x2019; blood pressure levels. Consequently, it is essential to subject future devices to rigorous testing with a dedicated validation protocol tailored for cuffless devices. These protocols should emphasize the ability to effectively track blood pressure variations for conditions commonly encountered in daily life.</p></sec><sec id="s4-2"><title>Limitations</title><p>This study had several limitations. First, it was conducted at a single center in Korea. The device algorithm was based on the Korean population during development, and this study was also conducted with Koreans. Second, although study participants were enrolled according to the AAMI/ESH/ISO protocol, we understand that this protocol should not be used for a cuffless device; therefore, further study is required with a validation protocol specifically designed for cuffless blood pressure devices. Third, both arms were used to detect test and reference blood pressure values simultaneously. Although participants with a history of peripheral vascular disease were not enrolled, the difference in reference blood pressures between both arms was not assessed prior to this study. Fourth, despite meeting the validation criteria suggested by the AAMI/ESH/ISO guidelines, our device&#x2019;s accuracy may not be sufficient for populations with high DBPs, as shown by the study results. Fifth, our study primarily included young and healthy participants; thus, the accuracy and applicability of our device for older and comorbid populations may be limited. Sixth, our study did not include the average agreement between the two observers and the frequency of device errors; therefore, further study is required to assess the functional consistency and reliability of the AlwaysBP software. Lastly, our data did not include information regarding the skin pigmentation of participants, which can have effects on the signal to noise ratio. Although our study exclusively recruited individuals of East Asian ethnicity and used LED technology from smartphones to obtain high-quality photoplethysmography data from participants&#x2019; fingers, the influence of an individual&#x2019;s skin pigmentation cannot be disregarded. Hence, an evaluation of the accuracy of the study device based on variations in skin pigmentation is necessary. Further investigations involving larger sample sizes with diverse comorbidities and skin colors are also required. Such additional studies should be conducted by an independent group for transparency and to mitigate potential bias [<xref ref-type="bibr" rid="ref26">26</xref>].</p></sec><sec id="s4-3"><title>Conclusion</title><p>This study assessed the accuracy of the AlwaysBP smartphone software, which was used to estimate blood pressure in 87 study participants. The cuffless smartphone software showed acceptable accuracy for SBP and DBP when compared with the reference cuff-based manual blood pressure measurement method, according to the AAMI/ESH/ISO protocol criteria. However, we understand that this protocol was only designed to validate cuff-based blood pressure measuring devices. Therefore, further validation studies with a specific validation protocol designed for cuffless blood pressure measuring devices are required to assess clinical accuracy.</p><p>The cuffless smartphone technology can be easily applied in everyday life, and it may improve the awareness and control of hypertension in the general population by enabling regular blood pressure monitoring, remote monitoring by health care providers, and programmed alerts and reminders for medication and measurement. Additionally, educational content can promote adherence to treatment plans and provide tips for managing hypertension.</p></sec></sec></body><back><ack><p>This work was supported by the Technology Innovation Program (20014477; development of a noncontact artificial intelligence health monitoring system based on multimodal sensors), funded by the Ministry of Trade, Industry &#x0026; Energy (MOTIE, Korea).</p></ack><notes><sec><title>Data Availability</title><p>The data that support the findings of this study are available from the corresponding author upon reasonable request.</p></sec></notes><fn-group><fn fn-type="con"><p>YHY contributed to conceptualization, the methodology, validation, the formal analysis, the investigation, resource management, data curation, the writing of the original draft, and visualization. JK, KJL, and DC contributed to conceptualization, the methodology, the design of the software, and resource management. JKO, MK, and JHR contributed to resource management. HWP contributed to resource management and the review and editing of this paper. JHL contributed to conceptualization, the review and editing of this paper, supervision, project administration, and funding acquisition.</p></fn><fn fn-type="conflict"><p>YHY and JHL serve as advisers for Deepmedi Inc, the owner of the AlwaysBP technology. KJL, JK, and DC are employees of Deepmedi Inc.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">AAMI/ESH/ISO</term><def><p>Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization</p></def></def-item><def-item><term id="abb2">DBP</term><def><p>diastolic blood pressure</p></def></def-item><def-item><term id="abb3">IMU</term><def><p>inertial measurement unit</p></def></def-item><def-item><term id="abb4">MBP</term><def><p>mean blood pressure</p></def></def-item><def-item><term id="abb5">PP</term><def><p>pulse pressure</p></def></def-item><def-item><term id="abb6">PTT</term><def><p>pulse transit time</p></def></def-item><def-item><term id="abb7">SBP</term><def><p>systolic blood pressure</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Roth</surname><given-names>GA</given-names></name><name name-style="western"><surname>Johnson</surname><given-names>C</given-names></name><name name-style="western"><surname>Abajobir</surname><given-names>A</given-names></name><name name-style="western"><surname>Abd-Allah</surname><given-names>F</given-names></name><name name-style="western"><surname>Abera</surname><given-names>SF</given-names></name><name name-style="western"><surname>Abyu</surname><given-names>G</given-names></name><etal/></person-group><article-title>Global, regional, and national burden of cardiovascular diseases for 10 causes, 1990 to 2015</article-title><source>J Am Coll Cardiol</source><year>2017</year><month>07</month><day>4</day><volume>70</volume><issue>1</issue><fpage>1</fpage><lpage>25</lpage><pub-id pub-id-type="doi">10.1016/j.jacc.2017.04.052</pub-id><pub-id pub-id-type="medline">28527533</pub-id></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bakris</surname><given-names>G</given-names></name><name name-style="western"><surname>Ali</surname><given-names>W</given-names></name><name name-style="western"><surname>Parati</surname><given-names>G</given-names></name></person-group><article-title>ACC/AHA versus ESC/ESH on hypertension guidelines: JACC guideline comparison</article-title><source>J Am Coll Cardiol</source><year>2019</year><month>06</month><day>18</day><volume>73</volume><issue>23</issue><fpage>3018</fpage><lpage>3026</lpage><pub-id pub-id-type="doi">10.1016/j.jacc.2019.03.507</pub-id><pub-id pub-id-type="medline">31196460</pub-id></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Williams</surname><given-names>B</given-names></name><name name-style="western"><surname>Mancia</surname><given-names>G</given-names></name><name name-style="western"><surname>Spiering</surname><given-names>W</given-names></name><name name-style="western"><surname>Agabiti Rosei</surname><given-names>E</given-names></name><name name-style="western"><surname>Azizi</surname><given-names>M</given-names></name><name name-style="western"><surname>Burnier</surname><given-names>M</given-names></name><etal/></person-group><article-title>ESC/ESH guidelines for the management of arterial hypertension</article-title><source>Eur Heart J</source><year>2018</year><month>09</month><day>1</day><volume>39</volume><issue>33</issue><fpage>3021</fpage><lpage>3104</lpage><pub-id pub-id-type="doi">10.1093/eurheartj/ehy339</pub-id><pub-id pub-id-type="medline">30165516</pub-id></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><collab>NCD Risk Factor Collaboration (NCD-RisC)</collab></person-group><article-title>Worldwide trends in hypertension prevalence and progress in treatment and control from 1990 to 2019: a pooled analysis of 1201 population-representative studies with 104 million participants</article-title><source>Lancet</source><year>2021</year><month>09</month><day>11</day><volume>398</volume><issue>10304</issue><fpage>957</fpage><lpage>980</lpage><pub-id pub-id-type="doi">10.1016/S0140-6736(21)01330-1</pub-id><pub-id pub-id-type="medline">34450083</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Moon</surname><given-names>JH</given-names></name><name name-style="western"><surname>Kang</surname><given-names>MK</given-names></name><name name-style="western"><surname>Choi</surname><given-names>CE</given-names></name><name name-style="western"><surname>Min</surname><given-names>J</given-names></name><name name-style="western"><surname>Lee</surname><given-names>HY</given-names></name><name name-style="western"><surname>Lim</surname><given-names>S</given-names></name></person-group><article-title>Validation of a wearable cuff-less wristwatch-type blood pressure monitoring device</article-title><source>Sci Rep</source><year>2020</year><month>11</month><day>4</day><volume>10</volume><issue>1</issue><fpage>19015</fpage><pub-id pub-id-type="doi">10.1038/s41598-020-75892-y</pub-id><pub-id pub-id-type="medline">33149118</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Degott</surname><given-names>J</given-names></name><name name-style="western"><surname>Ghajarzadeh-Wurzner</surname><given-names>A</given-names></name><name name-style="western"><surname>Hofmann</surname><given-names>G</given-names></name><name name-style="western"><surname>Proen&#x00E7;a</surname><given-names>M</given-names></name><name name-style="western"><surname>Bonnier</surname><given-names>G</given-names></name><name name-style="western"><surname>Lemkaddem</surname><given-names>A</given-names></name><etal/></person-group><article-title>Smartphone based blood pressure measurement: accuracy of the OptiBP mobile application according to the AAMI/ESH/ISO universal validation protocol</article-title><source>Blood Press Monit</source><year>2021</year><month>12</month><day>1</day><volume>26</volume><issue>6</issue><fpage>441</fpage><lpage>448</lpage><pub-id pub-id-type="doi">10.1097/MBP.0000000000000556</pub-id><pub-id pub-id-type="medline">34139747</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Vybornova</surname><given-names>A</given-names></name><name name-style="western"><surname>Polychronopoulou</surname><given-names>E</given-names></name><name name-style="western"><surname>Wurzner-Ghajarzadeh</surname><given-names>A</given-names></name><name name-style="western"><surname>Fallet</surname><given-names>S</given-names></name><name name-style="western"><surname>Sola</surname><given-names>J</given-names></name><name name-style="western"><surname>Wuerzner</surname><given-names>G</given-names></name></person-group><article-title>Blood pressure from the optical Aktiia Bracelet: a 1-month validation study using an extended ISO81060-2 protocol adapted for a cuffless wrist device</article-title><source>Blood Press Monit</source><year>2021</year><month>08</month><day>1</day><volume>26</volume><issue>4</issue><fpage>305</fpage><lpage>311</lpage><pub-id pub-id-type="doi">10.1097/MBP.0000000000000531</pub-id><pub-id pub-id-type="medline">33675592</pub-id></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Matsumura</surname><given-names>K</given-names></name><name name-style="western"><surname>Rolfe</surname><given-names>P</given-names></name><name name-style="western"><surname>Toda</surname><given-names>S</given-names></name><name name-style="western"><surname>Yamakoshi</surname><given-names>T</given-names></name></person-group><article-title>Cuffless blood pressure estimation using only a smartphone</article-title><source>Sci Rep</source><year>2018</year><month>05</month><day>8</day><volume>8</volume><issue>1</issue><fpage>7298</fpage><pub-id pub-id-type="doi">10.1038/s41598-018-25681-5</pub-id><pub-id pub-id-type="medline">29740088</pub-id></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Fortin</surname><given-names>J</given-names></name><name name-style="western"><surname>Rogge</surname><given-names>DE</given-names></name><name name-style="western"><surname>Fellner</surname><given-names>C</given-names></name><name name-style="western"><surname>Flotzinger</surname><given-names>D</given-names></name><name name-style="western"><surname>Grond</surname><given-names>J</given-names></name><name name-style="western"><surname>Lerche</surname><given-names>K</given-names></name><etal/></person-group><article-title>A novel art of continuous noninvasive blood pressure measurement</article-title><source>Nat Commun</source><year>2021</year><month>03</month><day>2</day><volume>12</volume><issue>1</issue><fpage>1387</fpage><pub-id pub-id-type="doi">10.1038/s41467-021-21271-8</pub-id><pub-id pub-id-type="medline">33654082</pub-id></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="web"><person-group person-group-type="author"><name name-style="western"><surname>Silver</surname><given-names>L</given-names></name><collab>Pew Research Center</collab></person-group><article-title>Smartphone ownership is growing rapidly around the world, but not always equally</article-title><year>2019</year><access-date>2023-08-17</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://www.pewresearch.org/global/2019/02/05/smartphone-ownership-is-growing-rapidly-around-the-world-but-not-always-equally/">www.pewresearch.org/global/2019/02/05/smartphone-ownership-is-growing-rapidly-around-the-world-but-not-always-equally/</ext-link></comment></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Scully</surname><given-names>CG</given-names></name><name name-style="western"><surname>Lee</surname><given-names>J</given-names></name><name name-style="western"><surname>Meyer</surname><given-names>J</given-names></name><name name-style="western"><surname>Gorbach</surname><given-names>AM</given-names></name><name name-style="western"><surname>Granquist-Fraser</surname><given-names>D</given-names></name><name name-style="western"><surname>Mendelson</surname><given-names>Y</given-names></name><etal/></person-group><article-title>Physiological parameter monitoring from optical recordings with a mobile phone</article-title><source>IEEE Trans Biomed Eng</source><year>2012</year><month>02</month><volume>59</volume><issue>2</issue><fpage>303</fpage><lpage>306</lpage><pub-id pub-id-type="doi">10.1109/TBME.2011.2163157</pub-id><pub-id pub-id-type="medline">21803676</pub-id></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Stergiou</surname><given-names>GS</given-names></name><name name-style="western"><surname>Alpert</surname><given-names>B</given-names></name><name name-style="western"><surname>Mieke</surname><given-names>S</given-names></name><name name-style="western"><surname>Asmar</surname><given-names>R</given-names></name><name name-style="western"><surname>Atkins</surname><given-names>N</given-names></name><name name-style="western"><surname>Eckert</surname><given-names>S</given-names></name><etal/></person-group><article-title>A universal standard for the validation of blood pressure measuring devices: Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) collaboration statement</article-title><source>J Hypertens</source><year>2018</year><month>03</month><volume>36</volume><issue>3</issue><fpage>472</fpage><lpage>478</lpage><pub-id pub-id-type="doi">10.1097/HJH.0000000000001634</pub-id><pub-id pub-id-type="medline">29384983</pub-id></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Stergiou</surname><given-names>GS</given-names></name><name name-style="western"><surname>Palatini</surname><given-names>P</given-names></name><name name-style="western"><surname>Asmar</surname><given-names>R</given-names></name><name name-style="western"><surname>Ioannidis</surname><given-names>JP</given-names></name><name name-style="western"><surname>Kollias</surname><given-names>A</given-names></name><name name-style="western"><surname>Lacy</surname><given-names>P</given-names></name><etal/></person-group><article-title>Recommendations and practical guidance for performing and reporting validation studies according to the Universal Standard for the validation of blood pressure measuring devices by the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO)</article-title><source>J Hypertens</source><year>2019</year><month>03</month><volume>37</volume><issue>3</issue><fpage>459</fpage><lpage>466</lpage><pub-id pub-id-type="doi">10.1097/HJH.0000000000002039</pub-id><pub-id pub-id-type="medline">30702492</pub-id></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Shao</surname><given-names>J</given-names></name><name name-style="western"><surname>Shi</surname><given-names>P</given-names></name><name name-style="western"><surname>Hu</surname><given-names>S</given-names></name><name name-style="western"><surname>Yu</surname><given-names>H</given-names></name></person-group><article-title>A revised point-to-point calibration approach with adaptive errors correction to weaken initial sensitivity of cuff-less blood pressure estimation</article-title><source>Sensors (Basel)</source><year>2020</year><month>04</month><day>13</day><volume>20</volume><issue>8</issue><fpage>2205</fpage><pub-id pub-id-type="doi">10.3390/s20082205</pub-id><pub-id pub-id-type="medline">32295090</pub-id></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Zheng</surname><given-names>YL</given-names></name><name name-style="western"><surname>Yan</surname><given-names>BP</given-names></name><name name-style="western"><surname>Zhang</surname><given-names>YT</given-names></name><name name-style="western"><surname>Poon</surname><given-names>CCY</given-names></name></person-group><article-title>An armband wearable device for overnight and cuff-less blood pressure measurement</article-title><source>IEEE Trans Biomed Eng</source><year>2014</year><month>07</month><volume>61</volume><issue>7</issue><fpage>2179</fpage><lpage>2186</lpage><pub-id pub-id-type="doi">10.1109/TBME.2014.2318779</pub-id><pub-id pub-id-type="medline">24760899</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Elgendi</surname><given-names>M</given-names></name><name name-style="western"><surname>Fletcher</surname><given-names>R</given-names></name><name name-style="western"><surname>Liang</surname><given-names>Y</given-names></name><name name-style="western"><surname>Howard</surname><given-names>N</given-names></name><name name-style="western"><surname>Lovell</surname><given-names>NH</given-names></name><name name-style="western"><surname>Abbott</surname><given-names>D</given-names></name><etal/></person-group><article-title>The use of photoplethysmography for assessing hypertension</article-title><source>NPJ Digit Med</source><year>2019</year><month>06</month><day>26</day><volume>2</volume><fpage>60</fpage><pub-id pub-id-type="doi">10.1038/s41746-019-0136-7</pub-id><pub-id pub-id-type="medline">31388564</pub-id></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Schoettker</surname><given-names>P</given-names></name><name name-style="western"><surname>Degott</surname><given-names>J</given-names></name><name name-style="western"><surname>Hofmann</surname><given-names>G</given-names></name><name name-style="western"><surname>Proen&#x00E7;a</surname><given-names>M</given-names></name><name name-style="western"><surname>Bonnier</surname><given-names>G</given-names></name><name name-style="western"><surname>Lemkaddem</surname><given-names>A</given-names></name><etal/></person-group><article-title>Blood pressure measurements with the OptiBP smartphone app validated against reference auscultatory measurements</article-title><source>Sci Rep</source><year>2020</year><month>10</month><day>20</day><volume>10</volume><issue>1</issue><fpage>17827</fpage><pub-id pub-id-type="doi">10.1038/s41598-020-74955-4</pub-id><pub-id pub-id-type="medline">33082436</pub-id></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Mukkamala</surname><given-names>R</given-names></name><name name-style="western"><surname>Hahn</surname><given-names>JO</given-names></name><name name-style="western"><surname>Inan</surname><given-names>OT</given-names></name><name name-style="western"><surname>Mestha</surname><given-names>LK</given-names></name><name name-style="western"><surname>Kim</surname><given-names>CS</given-names></name><name name-style="western"><surname>T&#x00F6;reyin</surname><given-names>H</given-names></name><etal/></person-group><article-title>Toward ubiquitous blood pressure monitoring via pulse transit time: theory and practice</article-title><source>IEEE Trans Biomed Eng</source><year>2015</year><month>08</month><volume>62</volume><issue>8</issue><fpage>1879</fpage><lpage>1901</lpage><pub-id pub-id-type="doi">10.1109/TBME.2015.2441951</pub-id><pub-id pub-id-type="medline">26057530</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lee</surname><given-names>J</given-names></name><name name-style="western"><surname>Yang</surname><given-names>S</given-names></name><name name-style="western"><surname>Lee</surname><given-names>S</given-names></name><name name-style="western"><surname>Kim</surname><given-names>HC</given-names></name></person-group><article-title>Analysis of pulse arrival time as an indicator of blood pressure in a large surgical biosignal database: recommendations for developing ubiquitous blood pressure monitoring methods</article-title><source>J Clin Med</source><year>2019</year><month>10</month><day>24</day><volume>8</volume><issue>11</issue><fpage>1773</fpage><pub-id pub-id-type="doi">10.3390/jcm8111773</pub-id><pub-id pub-id-type="medline">31653002</pub-id></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ding</surname><given-names>X</given-names></name><name name-style="western"><surname>Zhang</surname><given-names>YT</given-names></name></person-group><article-title>Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm</article-title><source>Biomed Eng Lett</source><year>2019</year><month>02</month><day>18</day><volume>9</volume><issue>1</issue><fpage>37</fpage><lpage>52</lpage><pub-id pub-id-type="doi">10.1007/s13534-019-00096-x</pub-id><pub-id pub-id-type="medline">30956879</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kim</surname><given-names>HL</given-names></name><name name-style="western"><surname>Kim</surname><given-names>SH</given-names></name></person-group><article-title>Pulse wave velocity in atherosclerosis</article-title><source>Front Cardiovasc Med</source><year>2019</year><month>04</month><day>9</day><volume>6</volume><fpage>41</fpage><pub-id pub-id-type="doi">10.3389/fcvm.2019.00041</pub-id><pub-id pub-id-type="medline">31024934</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Rai</surname><given-names>D</given-names></name><name name-style="western"><surname>Thakkar</surname><given-names>HK</given-names></name><name name-style="western"><surname>Rajput</surname><given-names>SS</given-names></name><name name-style="western"><surname>Santamaria</surname><given-names>J</given-names></name><name name-style="western"><surname>Bhatt</surname><given-names>C</given-names></name><name name-style="western"><surname>Roca</surname><given-names>F</given-names></name></person-group><article-title>A comprehensive review on seismocardiogram: current advancements on acquisition, annotation, and applications</article-title><source>Mathematics</source><year>2021</year><volume>9</volume><issue>18</issue><fpage>2243</fpage><pub-id pub-id-type="doi">10.3390/math9182243</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Mukkamala</surname><given-names>R</given-names></name><name name-style="western"><surname>Yavarimanesh</surname><given-names>M</given-names></name><name name-style="western"><surname>Natarajan</surname><given-names>K</given-names></name><name name-style="western"><surname>Hahn</surname><given-names>JO</given-names></name><name name-style="western"><surname>Kyriakoulis</surname><given-names>KG</given-names></name><name name-style="western"><surname>Avolio</surname><given-names>AP</given-names></name><etal/></person-group><article-title>Evaluation of the accuracy of cuffless blood pressure measurement devices: challenges and proposals</article-title><source>Hypertension</source><year>2021</year><month>11</month><volume>78</volume><issue>5</issue><fpage>1161</fpage><lpage>1167</lpage><pub-id pub-id-type="doi">10.1161/HYPERTENSIONAHA.121.17747</pub-id><pub-id pub-id-type="medline">34510915</pub-id></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Ibrahim</surname><given-names>B</given-names></name><name name-style="western"><surname>Jafari</surname><given-names>R</given-names></name></person-group><article-title>Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoder</article-title><source>Sci Rep</source><year>2022</year><month>01</month><day>10</day><volume>12</volume><issue>1</issue><fpage>319</fpage><pub-id pub-id-type="doi">10.1038/s41598-021-03612-1</pub-id><pub-id pub-id-type="medline">35013376</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Stergiou</surname><given-names>GS</given-names></name><name name-style="western"><surname>Mukkamala</surname><given-names>R</given-names></name><name name-style="western"><surname>Avolio</surname><given-names>A</given-names></name><name name-style="western"><surname>Kyriakoulis</surname><given-names>KG</given-names></name><name name-style="western"><surname>Mieke</surname><given-names>S</given-names></name><name name-style="western"><surname>Murray</surname><given-names>A</given-names></name><etal/></person-group><article-title>Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability</article-title><source>J Hypertens</source><year>2022</year><month>08</month><day>1</day><volume>40</volume><issue>8</issue><fpage>1449</fpage><lpage>1460</lpage><pub-id pub-id-type="doi">10.1097/HJH.0000000000003224</pub-id><pub-id pub-id-type="medline">35708294</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Whelton</surname><given-names>PK</given-names></name><name name-style="western"><surname>Picone</surname><given-names>DS</given-names></name><name name-style="western"><surname>Padwal</surname><given-names>R</given-names></name><name name-style="western"><surname>Campbell</surname><given-names>NRC</given-names></name><name name-style="western"><surname>Drawz</surname><given-names>P</given-names></name><name name-style="western"><surname>Rakotz</surname><given-names>MK</given-names></name><etal/></person-group><article-title>Global proliferation and clinical consequences of non-validated automated BP devices</article-title><source>J Hum Hypertens</source><year>2023</year><month>02</month><volume>37</volume><issue>2</issue><fpage>115</fpage><lpage>119</lpage><pub-id pub-id-type="doi">10.1038/s41371-022-00667-z</pub-id><pub-id pub-id-type="medline">35279699</pub-id></nlm-citation></ref></ref-list></back></article>