<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.0 20040830//EN" "journalpublishing.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="2.0" xml:lang="en" article-type="research-article"><front><journal-meta><journal-id journal-id-type="nlm-ta">JMIR Mhealth Uhealth</journal-id><journal-id journal-id-type="publisher-id">mhealth</journal-id><journal-id journal-id-type="index">13</journal-id><journal-title>JMIR mHealth and uHealth</journal-title><abbrev-journal-title>JMIR Mhealth Uhealth</abbrev-journal-title><issn pub-type="epub">2291-5222</issn><publisher><publisher-name>JMIR Publications</publisher-name><publisher-loc>Toronto, Canada</publisher-loc></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">v13i1e46149</article-id><article-id pub-id-type="doi">10.2196/46149</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Paper</subject></subj-group></article-categories><title-group><article-title>Using Wear Time for the Analysis of Consumer-Grade Wearables&#x2019; Data: Case Study Using Fitbit Data</article-title></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name name-style="western"><surname>Baroudi</surname><given-names>Loubna</given-names></name><degrees>MSc</degrees><xref ref-type="aff" rid="aff1">1</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Zernicke</surname><given-names>Ronald Fredrick</given-names></name><degrees>MSc, ND, PhD</degrees><xref ref-type="aff" rid="aff2">2</xref><xref ref-type="aff" rid="aff3">3</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Tewari</surname><given-names>Muneesh</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff4">4</xref><xref ref-type="aff" rid="aff5">5</xref><xref ref-type="aff" rid="aff6">6</xref><xref ref-type="aff" rid="aff7">7</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Carlozzi</surname><given-names>Noelle E</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff8">8</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Choi</surname><given-names>Sung Won</given-names></name><degrees>MSc, MD</degrees><xref ref-type="aff" rid="aff9">9</xref></contrib><contrib contrib-type="author"><name name-style="western"><surname>Cain</surname><given-names>Stephen M</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="aff10">10</xref></contrib></contrib-group><aff id="aff1"><institution>Department of Mechanical Engineering, University of Michigan&#x2013;Ann Arbor</institution><addr-line>2505 Hayward St</addr-line><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff2"><institution>Department of Orthopedic Surgery, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff3"><institution>Exercise &#x0026; Sport Science Initiative, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff4"><institution>Center for Computational Medicine and Bioinformatics, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff5"><institution>Department of Internal Medicine, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff6"><institution>Department of Biomedical Engineering, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff7"><institution>Veterans Administration Ann Arbor Healthcare System, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff8"><institution>Department of Physical Medicine and Rehabilitation, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff9"><institution>Department of Pediatrics, University of Michigan&#x2013;Ann Arbor</institution><addr-line>Ann Arbor</addr-line><addr-line>MI</addr-line><country>United States</country></aff><aff id="aff10"><institution>Department of Chemical and Biomedical Engineering, West Virginia University</institution><addr-line>Morgantown</addr-line><addr-line>WV</addr-line><country>United States</country></aff><contrib-group><contrib contrib-type="editor"><name name-style="western"><surname>Buis</surname><given-names>Lorraine</given-names></name></contrib></contrib-group><contrib-group><contrib contrib-type="reviewer"><name name-style="western"><surname>Martinko</surname><given-names>Antonio</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Toledo</surname><given-names>Meynard John</given-names></name></contrib><contrib contrib-type="reviewer"><name name-style="western"><surname>Wang</surname><given-names>Yao-Chin</given-names></name></contrib></contrib-group><author-notes><corresp>Correspondence to Loubna Baroudi, MSc, Department of Mechanical Engineering, University of Michigan&#x2013;Ann Arbor, 2505 Hayward St, Ann Arbor, MI, 48109, United States, 1 7342626353; <email>lbaroudi@umich.edu</email></corresp></author-notes><pub-date pub-type="collection"><year>2025</year></pub-date><pub-date pub-type="epub"><day>21</day><month>3</month><year>2025</year></pub-date><volume>13</volume><elocation-id>e46149</elocation-id><history><date date-type="received"><day>31</day><month>01</month><year>2023</year></date><date date-type="rev-recd"><day>02</day><month>09</month><year>2024</year></date><date date-type="accepted"><day>20</day><month>12</month><year>2024</year></date></history><copyright-statement>&#x00A9; Loubna Baroudi, Ronald Fredrick Zernicke, Muneesh Tewari, Noelle E Carlozzi, Sung Won Choi, Stephen M Cain. Originally published in JMIR mHealth and uHealth (<ext-link ext-link-type="uri" xlink:href="https://mhealth.jmir.org">https://mhealth.jmir.org</ext-link>), 21.3.2025. </copyright-statement><copyright-year>2025</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><p>This is an open-access article distributed under the terms of the Creative Commons Attribution License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on <ext-link ext-link-type="uri" xlink:href="https://mhealth.jmir.org/">https://mhealth.jmir.org/</ext-link>, as well as this copyright and license information must be included.</p></license><self-uri xlink:type="simple" xlink:href="https://mhealth.jmir.org/2025/1/e46149"/><abstract><sec><title>Background</title><p>Consumer-grade wearables allow researchers to capture a representative picture of human behavior in the real world over extended periods. However, maintaining users&#x2019; engagement remains a challenge and can lead to a decrease in compliance (eg, wear time in the context of wearable sensors) over time (eg, &#x201C;wearables&#x2019; abandonment&#x201D;).</p></sec><sec><title>Objective</title><p>In this work, we analyzed datasets from diverse populations (eg, caregivers for various health issues, college students, and pediatric oncology patients) to quantify the impact that wear time requirements can have on study results. We found evidence that emphasizes the need to account for participants&#x2019; wear time in the analysis of consumer-grade wearables data. In Aim 1, we demonstrate the sensitivity of parameter estimates to different data processing methods with respect to wear time. In Aim 2, we demonstrate that not all research questions necessitate the same wear time requirements; some parameter estimates are not sensitive to wear time.</p></sec><sec sec-type="methods"><title>Methods</title><p>We analyzed 3 Fitbit datasets comprising 6 different clinical and healthy population samples. For Aim 1, we analyzed the sensitivity of average daily step count and average daily heart rate at the population sample and individual levels to different methods of defining &#x201C;valid&#x201D; days using wear time. For Aim 2, we evaluated whether some research questions can be answered with data from lower compliance population samples. We explored (1) the estimation of the average daily step count and (2) the estimation of the average heart rate while walking.</p></sec><sec sec-type="results"><title>Results</title><p>For Aim 1, we found that the changes in the population sample average daily step count could reach 2000 steps for different methods of analysis and were dependent on the wear time compliance of the sample. As expected, population samples with a low daily wear time (less than 15 hours of wear time per day) showed the most sensitivity to changes in methods of analysis. On the individual level, we observed that around 15% of individuals had a difference in step count higher than 1000 steps for 4 of the 6 population samples analyzed when using different data processing methods. Those individual differences were higher than 3000 steps for close to 5% of individuals across all population samples. Average daily heart rate appeared to be robust to changes in wear time. For Aim 2, we found that, for 5 population samples out of 6, around 11% of individuals had enough data for the estimation of average heart rate while walking but not for the estimation of their average daily step count.</p></sec><sec sec-type="conclusions"><title>Conclusions</title><p>We leveraged datasets from diverse populations to demonstrate the direct relationship between parameter estimates from consumer-grade wearable devices and participants&#x2019; wear time. Our findings highlighted the importance of a thorough analysis of wear time when processing data from consumer-grade wearables to ensure the relevance and reliability of the associated findings.</p></sec></abstract><kwd-group><kwd>wear time</kwd><kwd>wearables</kwd><kwd>smartwatch</kwd><kwd>mobile health</kwd><kwd>physical activity</kwd><kwd>engagement</kwd><kwd>walking</kwd><kwd>dataset</kwd><kwd>wearable devices</kwd><kwd>reliability</kwd><kwd>behavior</kwd><kwd>caregiver</kwd><kwd>students</kwd><kwd>Fitbit</kwd><kwd>users</kwd></kwd-group></article-meta></front><body><sec id="s1" sec-type="intro"><title>Introduction</title><p>Physical activity can be used to prevent and treat multifarious health issues. In the clinical setting and in research studies, the assessment of physical activity level is often carried out using self-report questionnaires. However, because self-reports are low in resolution, subjective, and often limited in scope, researchers have been looking for solutions to objectively quantify physical activity [<xref ref-type="bibr" rid="ref1">1</xref>,<xref ref-type="bibr" rid="ref2">2</xref>]. In the early 21st century, smartwatches and fitness trackers entered the consumer market [<xref ref-type="bibr" rid="ref3">3</xref>]. These consumer-grade devices integrate a combination of sensors to measure key health metrics such as step count or heart rate. With the realization that fitness trackers can motivate users to exercise by providing them with real-time feedback, researchers and clinicians are now increasingly using these devices to monitor individuals [<xref ref-type="bibr" rid="ref4">4</xref>-<xref ref-type="bibr" rid="ref7">7</xref>]. In particular, Fitbit (Google Inc) smartwatches have imposed themselves in the clinical world due to their low price, high battery life, user-friendliness, and compatibility with most smartphones on the market. However, useful data can only be collected if participants are compliant and wear the watch.</p><p>With longitudinal studies, it can be challenging to maintain users&#x2019; engagement and compliance. It is common to observe what is called &#x201C;wearables&#x2019; abandonment&#x201D;; as the excitement from having a new gadget wears off, people start to wear the sensors less and less [<xref ref-type="bibr" rid="ref8">8</xref>]. In the accelerometer research&#x2014;where accelerometers are commonly used to monitor physical activity&#x2014;researchers have established different methods to account for wear time in the data processing pipeline [<xref ref-type="bibr" rid="ref9">9</xref>-<xref ref-type="bibr" rid="ref12">12</xref>]. In both the Fitbit and the accelerometer literature, when wear time is considered, researchers use different thresholds on daily wear time or on step count to preprocess their data and extract valid days [<xref ref-type="bibr" rid="ref13">13</xref>-<xref ref-type="bibr" rid="ref16">16</xref>]. However, as wear time and activity levels vary for each study population, those thresholds might not always be generalizable or may be overly strict for some research questions. For instance, a very active population might need a higher step count threshold compared to a sedentary population. This suggests that researchers should evaluate whether their selected wear time requirements are appropriate for their study population and research question to ensure the validity of their data processing [<xref ref-type="bibr" rid="ref17">17</xref>]. Researchers should also present a justification for their wear time requirements. Furthermore, as different research questions might require a different amount of data, the required amount of data will need to be adapted.</p><p>In this work, we aimed to further the understanding of the effects of compliance on parameter estimates. Our objective was to (Aim 1) quantify the sensitivity of calculations to different wear time requirements between and within different population samples and (Aim 2) demonstrate that not all research questions may require identical wear time requirements. We leveraged three Fitbit datasets from six different populations to illustrate this work: the estimation of the average (1) daily step count, (2) daily heart rate, and (3) average heart rate while walking. As the use of consumer-grade wearables is rapidly increasing, this work provides a thorough demonstration of the potential impact of wear time on essential parameter estimates in a diversity of populations (clinical and nonclinical) with varying degrees of compliance. This work provides quantitative evidence of the need to use wear time requirements in data analyses, specifically for study population samples with low compliance.</p></sec><sec id="s2" sec-type="methods"><title>Methods</title><sec id="s2-1"><title>Description of Datasets</title><p>For this study, 3 Fitbit datasets from 6 different populations were used (<xref ref-type="table" rid="table1">Table 1</xref>).</p><table-wrap id="t1" position="float"><label>Table 1.</label><caption><p>Dataset details.</p></caption><table id="table1" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom">Dataset</td><td align="left" valign="bottom" colspan="3">Caregivers</td><td align="left" valign="bottom">Students</td><td align="left" valign="bottom" colspan="2">Pediatric oncology</td></tr><tr><td align="left" valign="top"/><td align="left" valign="top">Hematopoietic cell transplantation</td><td align="left" valign="top">Huntington disease</td><td align="left" valign="top">Spinal cord injury</td><td align="left" valign="top"/><td align="left" valign="top">Caregivers</td><td align="left" valign="top">Patients</td></tr></thead><tbody><tr><td align="left" valign="top">Sample size, n</td><td align="left" valign="top">30</td><td align="left" valign="top">21</td><td align="left" valign="top">19</td><td align="left" valign="top">2107</td><td align="left" valign="top">49</td><td align="left" valign="top">44</td></tr><tr><td align="left" valign="top">Study length, days</td><td align="left" valign="top">90</td><td align="left" valign="top">90</td><td align="left" valign="top">90</td><td align="left" valign="top">90</td><td align="left" valign="top">120</td><td align="left" valign="top">120</td></tr><tr><td align="left" valign="top">Fitbit type</td><td align="left" valign="top">Fitbit Inspire 2</td><td align="left" valign="top">Fitbit Inspire 2</td><td align="left" valign="top">Fitbit Inspire 2</td><td align="left" valign="top">Fitbit Charge</td><td align="left" valign="top">Fitbit Charge</td><td align="left" valign="top">Fitbit Charge</td></tr><tr><td align="left" valign="top">Fitbit wear instructions</td><td align="left" valign="top">Wear as much as possible</td><td align="left" valign="top">Wear as much as possible</td><td align="left" valign="top">Wear as much as possible</td><td align="left" valign="top">40 h/wk</td><td align="left" valign="top">Wear as much as possible</td><td align="left" valign="top">Wear as much as possible</td></tr><tr><td align="left" valign="top">Fitbit wear incentives</td><td align="left" valign="top">Fitbit given + US $1/day if some Fitbit OR survey data</td><td align="left" valign="top">Fitbit given + US $1/day if some Fitbit OR survey data</td><td align="left" valign="top">Fitbit given + US $1/day if some Fitbit OR survey data</td><td align="left" valign="top">Fitbit given</td><td align="left" valign="top">Fitbit given</td><td align="left" valign="top">Fitbit given</td></tr></tbody></table></table-wrap><sec id="s2-1-1"><title>Three Different Caregiver Groups</title><p>The details of this study protocol can be found in Carlozzi et al [<xref ref-type="bibr" rid="ref18">18</xref>]. Briefly, caregivers for persons with Huntington disease (HD), spinal cord injury (SCI), and hematopoietic cell transplantation (HCT) from different clinics at the University of Michigan were recruited between November 2020 and June 2021. This study&#x2019;s objective was to evaluate a just-in-time adaptive intervention to promote caregivers&#x2019; self-care. This intervention leveraged the combination of Fitbit and survey data collected using an app (TBI-CareQOL). It is important to note that participants were reminded to sync their Fitbit data every Monday and Friday if they had not already done so.</p></sec><sec id="s2-1-2"><title>College Students</title><p>The details of this study protocol can be found in Cislo et al [<xref ref-type="bibr" rid="ref19">19</xref>]. Briefly, graduate and undergraduate students at the University of Michigan were recruited between September 2020 and December 2020 to study students&#x2019; mental health and physical activity during the COVID-19 pandemic. Different measures were collected using surveys, a smartphone app (Roadmap 2.0), and a Fitbit smartwatch.</p></sec><sec id="s2-1-3"><title>Pediatric Oncology Caregivers and Patients</title><p>This dataset was collected in a study evaluating the use of a mobile health app (Roadmap 2.0) intervention for cancer caregivers and their patients [<xref ref-type="bibr" rid="ref20">20</xref>]. Participants were recruited between September 2020 and September 2021 from the Adult and Pediatric Hematology and Oncology Units of Mott Children&#x2019;s Hospital in Ann Arbor, MI.</p></sec></sec><sec id="s2-2"><title>Data Analysis and Statistics</title><sec id="s2-2-1"><title>Compliance Levels for Each Population</title><p>We first compared the level of compliance and wear time for each population. To calculate wear time, we used the heart rate data from the Fitbit watch [<xref ref-type="bibr" rid="ref13">13</xref>]. A heart rate value was registered by the watch every minute if the watch was worn. Thus, wear time was calculated as follows:</p><disp-formula id="E1"><label>(1)</label><mml:math id="eqn1"><mml:mstyle displaystyle="true" scriptlevel="0"><mml:mrow><mml:mrow><mml:mtext mathvariant="italic">Wear time</mml:mtext><mml:mo mathvariant="italic">=</mml:mo><mml:mfrac><mml:mtext mathvariant="italic"># Minutes of registered heart rate</mml:mtext><mml:mtext mathvariant="italic">Total minutes</mml:mtext></mml:mfrac></mml:mrow></mml:mrow></mml:mstyle></mml:math></disp-formula><p>Total minutes depended on the time frame of interest. For instance, if we wanted to calculate wear time over 24 hours, the total number of minutes was 1440 minutes. Because our groups did not have a similar variance, and the sample sizes were largely different, the difference in wear time between groups was evaluated using a Kruskal-Wallis test [<xref ref-type="bibr" rid="ref21">21</xref>]. If the omnibus test was significant, the Dunn test was used to evaluate pairwise differences [<xref ref-type="bibr" rid="ref22">22</xref>]. Significance was evaluated at the .05 level.</p></sec><sec id="s2-2-2"><title>Aim 1: Sensitivity of Parameter Estimates to Different Wear Time Requirements</title><p>For Aim 1, three different definitions of compliance were used to evaluate the impact on the evaluation of the average daily step count and average daily heart rate for the population and the individual. Both of these measures have been used to determine fitness levels in multifarious populations [<xref ref-type="bibr" rid="ref20">20</xref>-<xref ref-type="bibr" rid="ref22">22</xref>]. Compliance was expressed in the form of valid days, where a valid day corresponded to a day that met a certain criterion and was kept for analysis. The 3 different definitions of a valid day were as follows: (<italic>None</italic>) all days were considered valid, (<italic>StepCount1000</italic>) a day was valid if the step count registered for that day was greater than 1000, and (<italic>WearTime80</italic>) a day was valid if the wear time that day (24 hours) was greater than 80% (19.2 hours). For that last definition, wear time was calculated using equation (1). The definitions of a valid day <italic>StepCount1000</italic> and <italic>WearTime80</italic> were based on studies found in the literature [<xref ref-type="bibr" rid="ref13">13</xref>,<xref ref-type="bibr" rid="ref14">14</xref>]. These 2 definitions also offer different perspectives on wear time by leveraging 2 distinct data types (step count vs wear time, defined here using heart rate). We also added the definition <italic>None</italic> to demonstrate the impact of not including wear time in analyses, which is the case in a large number of studies that use consumer-grade wearables [<xref ref-type="bibr" rid="ref17">17</xref>]. The average daily step count and heart rate were calculated for the population and each individual using these 3 different definitions. The code to extract participants&#x2019; wear time using Fitbit heart rate data and evaluate effects on step count is available on GitHub [<xref ref-type="bibr" rid="ref23">23</xref>]. This repository includes the data preprocessing scripts and analysis code using an open-source Fitbit dataset.</p></sec><sec id="s2-2-3"><title>Aim 2: Effect of Compliance on the Research Objective</title><p>For Aim 2, we examined the effect of compliance on the ability to address different research questions. We wanted to investigate whether some research questions can be answered, even when subject compliance is poor. Two research objectives were compared for this aim: (1) the evaluation of average daily step count and (2) the evaluation of average heart rate while walking. Heart rate while walking can be an indicator of cardiac health and exercise intensity [<xref ref-type="bibr" rid="ref24">24</xref>-<xref ref-type="bibr" rid="ref26">26</xref>]. To obtain heart rate while walking, we used Fitbit&#x2019;s number of steps taken in a minute and isolated instances where that value was above 80 steps taken in a minute. That indicated a high likelihood for an individual to be on a walk [<xref ref-type="bibr" rid="ref27">27</xref>]. Then, we isolated the values of heart rate corresponding to those instances that we named walking heart rate. To determine the minimal number of samples of walking heart rate (eg, the number of data points of heart rate corresponding to our definition of walking heart rate) needed to converge to a confident average, the standard error was calculated for an increasing random number of samples. A threshold of 1 bpm (beats per minute) was set for convergence (<xref ref-type="fig" rid="figure1">Figure 1</xref>). Once the minimum number of samples necessary for each individual was found, the number of days needed to get this amount of samples was extracted.</p><fig position="float" id="figure1"><label>Figure 1.</label><caption><p>Evolution of average steps taken in a minute (A) and standard error (in steps) (B and C) with an increase in the number of samples for a representative subject. (C) is the expansion of (B) to visualize the number of samples necessary for this individual to obtain a standard error below 2. bpm: beats per minute.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v13i1e46149_fig01.png"/></fig></sec></sec><sec id="s2-3"><title>Ethical Considerations</title><p>All datasets were generated by teams at Michigan Medicine at the University of Michigan, and the different data collection protocols were each approved by the University of Michigan institutional review board, under the review numbers HUM00186436, HUM00176584, HUM00184455, and HUM00185391. All participants provided informed consent prior to their participation in the study. The details of the compensation for each study are provided in <xref ref-type="table" rid="table1">Table 1</xref>.</p></sec></sec><sec id="s3" sec-type="results"><title>Results</title><sec id="s3-1"><title>Wear Time</title><p>The average wear time of the device varied by population (<xref ref-type="fig" rid="figure2">Figure 2</xref>). The most compliant sample was the HCT caregivers with an average daily wear time of 20.8 hours. The least compliant sample was the pediatric oncology patients with an average daily wear time of 9.8 hours. Differences were also observed in the spread of the data. For the pediatric oncology patients and caregivers and the student sample, the distribution went from 0% to above 90% of wear time. A 0% wear time indicated that participants received the Fitbit but never wore it.</p><p>There were significant differences in the average wear time between populations (<xref ref-type="table" rid="table2">Table 2</xref>). Notably, the pediatric oncology patients had significantly lower wear time than all other studied samples except for the pediatric oncology caregivers. The HCT caregivers also had significantly higher wear time than the other groups, except for the SCI and HD caregivers.</p><p>A decrease was observed in monthly wear time for all recruited groups. The average decrease was a little more than 10%, with the highest decrease recorded for the pediatric oncology patients (&#x2212;19%) and the lowest decrease recorded for the HCT caregivers (&#x2212;8%).</p><fig position="float" id="figure2"><label>Figure 2.</label><caption><p>Distribution of average daily wear time in percentages (left) and hours (right) for each recruited sample. The pediatric oncology patients and caregivers population, as well as the student population, had participants that were given a Fitbit and never wore it. As such, there are instances with 0 hours of daily wear time in the distributions. HCT: hematopoietic cell transplantation; HD: Huntington disease; SCI: spinal cord injury.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v13i1e46149_fig02.png"/></fig><table-wrap id="t2" position="float"><label>Table 2.</label><caption><p>Model coefficients and significance from post hoc test evaluating the difference in wear time between samples.</p></caption><table id="table2" frame="hsides" rules="groups"><thead><tr><td align="left" valign="bottom"/><td align="left" valign="bottom">HCT<sup><xref ref-type="table-fn" rid="table2fn1">a</xref></sup></td><td align="left" valign="bottom">HD<sup><xref ref-type="table-fn" rid="table2fn2">b</xref></sup></td><td align="left" valign="bottom">SCI<sup><xref ref-type="table-fn" rid="table2fn3">c</xref></sup></td><td align="left" valign="bottom">Students</td><td align="left" valign="bottom">Pediatric oncology caregivers</td></tr></thead><tbody><tr><td align="left" valign="top">HD</td><td align="left" valign="top">0.52</td><td align="left" valign="top">&#x2014;<sup><xref ref-type="table-fn" rid="table2fn4">d</xref></sup></td><td align="left" valign="top">&#x2014;</td><td align="left" valign="top">&#x2014;</td><td align="left" valign="top">&#x2014;</td></tr><tr><td align="left" valign="top">SCI</td><td align="left" valign="top">1.04</td><td align="left" valign="top">0.5</td><td align="left" valign="top">&#x2014;</td><td align="left" valign="top">&#x2014;</td><td align="left" valign="top">&#x2014;</td></tr><tr><td align="left" valign="top">Students</td><td align="left" valign="top">4.23<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="top">2.88</td><td align="left" valign="top">2.04</td><td align="left" valign="top">&#x2014;</td><td align="left" valign="top">&#x2014;</td></tr><tr><td align="left" valign="top">Pediatric oncology caregivers</td><td align="left" valign="top">3.68<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="top">2.7</td><td align="left" valign="top">2.02</td><td align="left" valign="top">0.52</td><td align="left" valign="top">&#x2014;</td></tr><tr><td align="left" valign="top">Pediatric oncology patients</td><td align="left" valign="top">5.83<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="top">4.65<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="top">3.91<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="top">3.96<sup><xref ref-type="table-fn" rid="table2fn5">e</xref></sup></td><td align="left" valign="top">2.54</td></tr></tbody></table><table-wrap-foot><fn id="table2fn1"><p><sup>a</sup>HCT: hematopoietic cell transplantation.</p></fn><fn id="table2fn2"><p><sup>b</sup>HD: Huntington disease.</p></fn><fn id="table2fn3"><p><sup>c</sup>SCI: spinal cord injury.</p></fn><fn id="table2fn4"><p><sup>d</sup>Not applicable.</p></fn><fn id="table2fn5"><p><sup>e</sup><italic>P</italic>&#x003C;.001.</p></fn></table-wrap-foot></table-wrap></sec><sec id="s3-2"><title>Aim 1</title><sec id="s3-2-1"><title>Population Level</title><p>First, we observed the changes in the sample average daily step count for the 3 chosen definitions of a valid day (<xref ref-type="fig" rid="figure3">Figure 3</xref>). The average number of valid days decreased between 15% and 33% from the definition <italic>None</italic> to <italic>WearTime80</italic>. The decrease from <italic>None</italic> to <italic>StepCount1000</italic> was around 12% for the SCI caregivers and the pediatric oncology patients and close to 0% for the other samples. There was also a decrease from <italic>StepCount1000</italic> to <italic>WearTime80</italic> from 12% to 21%. The change in average daily step count was dependent on the sample. HCT and HD caregivers both showed a difference smaller than 15 steps between <italic>None</italic> and <italic>WearTime80</italic>. On the other hand, the pediatric oncology patients showed a difference of almost 2000 steps between <italic>None</italic> and <italic>WearTime80</italic>. The sample sizes decreased from <italic>None</italic> to <italic>WearTime80</italic> for the pediatric oncology patients, caregivers, and students (n=6, &#x2212;14%; n=10, &#x2212;20%; and n=7, &#x2212;8%; respectively).</p><p>We also analyzed changes in the sample average daily heart rate for the 3 definitions. We found only small differences in average daily heart rate for all samples. The student sample showed the largest difference of 3 bpm between <italic>None</italic> and <italic>WearTime80</italic>.</p><fig position="float" id="figure3"><label>Figure 3.</label><caption><p>Average daily step count across samples for the different definitions of a valid day. The effect of these different definitions was dependent on the sample, going from less than 80 steps for the HD sample to almost 2000 steps for the pediatric oncology patients. HCT: hematopoietic cell transplantation; HD: Huntington disease; SCI: spinal cord injury.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v13i1e46149_fig03.png"/></fig></sec><sec id="s3-2-2"><title>Individual Level</title><p>We assessed the changes in each individual&#x2019;s average daily step count (<xref ref-type="fig" rid="figure4">Figure 4</xref>). We binned individuals based on the average daily step count difference between <italic>None</italic> and <italic>WearTime80,</italic> since those definitions were the least and most stringent, respectively (<xref ref-type="fig" rid="figure4">Figure 4A</xref>). For all samples, the majority of individuals had a difference in average daily step count between 0 and 500 steps. The HCT caregivers had the least differences in individual steps, followed by the HD caregivers. Approximately, a quarter of the SCI caregivers, pediatric oncology patients and caregivers, and students had a step count difference higher than 1000. By taking a closer look at the individuals in each bin for a group (<xref ref-type="fig" rid="figure4">Figure 4B</xref>), we saw that participants like participant A did not display any difference in average daily step count between each definition. However, participants like participant E showed a difference higher than 3000 steps between each definition, with that difference reaching almost 7000 steps between <italic>None</italic> and <italic>WearTime80</italic>.</p><p>Little to no variation was observed within participants for the average daily heart rate between <italic>None</italic> and <italic>WearTime80</italic>. Only 3% (n=1) of the pediatric oncology patient participants had a difference between 5 and 10 bpm, and less than 1% (n=21) of students had a difference between 10 and 15 bpm.</p><fig position="float" id="figure4"><label>Figure 4.</label><caption><p>(A) Individual differences in average daily step count calculated using <italic>None</italic> versus <italic>WearTime80</italic>. For example, 21% (n=6) of the HCT sample had a difference in average daily step count between 500 and 999 steps when calculations were made using <italic>WearTime80</italic> versus <italic>None</italic>. The grouping of the step differences was inspired by the physical activity level categories presented by Tudor-Locke and Bassett [<xref ref-type="bibr" rid="ref28">28</xref>]. (B) Five representative participants&#x2019; average daily step count from the different slices of difference in step count, using the 3 definitions of a valid day. For example, participant E was representative of students who had a difference in average daily step count larger than 5000 when calculated with <italic>WearTime80</italic> compared to <italic>None</italic>. HCT: hematopoietic cell transplantation; HD: Huntington disease; SCI: spinal cord injury.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v13i1e46149_fig04.png"/></fig></sec></sec><sec id="s3-3"><title>Aim 2</title><p>On average, across all population samples, 304 samples (minutes of walking) were needed to obtain an estimate of the walking heart rate with a standard error of 1 bpm. For most individuals, the minimal number of samples was reached in under 26 days of data collection. For the pediatric oncology caregivers, 1 participant did not have enough samples to obtain a confident estimate of the walking heart rate, but an estimate of that caregiver&#x2019;s average daily step count using <italic>WearTime80</italic> was obtained. On the other hand, 5 (17%) HCT, 3 (14%) HD, 2 (11%) SCI, 186 (10%) students, and 3 (7%) of the pediatric oncology patients did not have any valid days to calculate their average daily step count but presented enough samples to confidently obtain their walking heart rate. <xref ref-type="fig" rid="figure5">Figure 5</xref> illustrates an individual&#x2019;s data from the student sample within that 10%. That individual wore the Fitbit at the beginning and the end of the study for around 50% of the day. That student had 1314 samples of steps taken in a minute&#x2014;enough to estimate walking heart rate&#x2014;while presenting no days with a wear time higher than 80%.</p><fig position="float" id="figure5"><label>Figure 5.</label><caption><p>Wear time (black line, left axis) and steps taken in a minute (blue and orange dots, right axis) over time for an individual from the student sample. Average daily step count using <italic>WearTime80</italic> with this participant was not possible as no days presented a wear time larger than 80%. However, there was a sufficient number of samples to confidently estimate walking heart rate based on the number of samples of steps taken in a minute that was above 80.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v13i1e46149_fig05.png"/></fig></sec></sec><sec id="s4" sec-type="discussion"><title>Discussion</title><sec id="s4-1"><title>Principal Results</title><p>The purpose of this study was to quantify how wear time could impact parameter estimates in studies using consumer-grade wearables by using real-world samples with varying participant compliance. This work is distinguished from the literature by demonstrating the conditional nature of wear time&#x2019;s influence in consumer-grade wearables&#x2019; data, which varies significantly across research samples and research questions. By leveraging a broad array of datasets, including vulnerable patient populations<underline>,</underline> we showed evidence of the nuanced effect of wear time, highlighting its critical role in research using wearables, especially in samples with inconsistent wear patterns such as the pediatric oncology caregiver and patient participants used in this study. It is important to note that the pediatric oncology patients&#x2019; ages ranged from 5 to 20 years, with a mean of 11.9 years. The young age combined with illness for these subjects likely explained this population sample&#x2019;s low level of wear time with large variability.</p><p>Unsurprisingly, implementing different wear time requirements to define a valid day can significantly impact parameter estimates, especially in samples with low compliance. Wear time compliance for the HD and HCT caregivers was high (<xref ref-type="fig" rid="figure6">Figure 6</xref>); therefore, the estimates of the samples&#x2019; average daily step counts were minimally affected by different definitions of a valid day (<xref ref-type="fig" rid="figure3">Figure 3</xref>). In comparison, the pediatric oncology patient sample had low wear time compliance (<xref ref-type="fig" rid="figure6">Figure 6</xref>); therefore, the estimate of the sample average daily step count was significantly impacted by different definitions of a valid day (<xref ref-type="fig" rid="figure3">Figure 3</xref>). Importantly, our analysis quantifies these differences so that other researchers can better understand the potential implications of different valid day definitions. The definition of a valid day had almost no impact on estimates of the average daily heart rate across samples. This also is not surprising as heart rate is a more stable measure that does not necessarily correlate with wear time; any biases from missing data are averaged out.</p><fig position="float" id="figure6"><label>Figure 6.</label><caption><p>Monthly average daily wear time in percentages (left) and hours (right). We observed a monthly decrease in wear time for all groups symptomatic of the phenomenon of wearables&#x2019; abandonment. The pediatric oncology dataset was collected over 120 days versus 90 days for the other datasets. HCT: hematopoietic cell transplantation; HD: Huntington disease; SCI: spinal cord injury.</p></caption><graphic alt-version="no" mimetype="image" position="float" xlink:type="simple" xlink:href="mhealth_v13i1e46149_fig06.png"/></fig><p>A significant novelty in this work is demonstrating the flexibility of data usage in real-world settings (ie, outside of the hospital). In fact, we showed that even if an individual&#x2019;s data were not sufficient to answer a specific research question, those data could potentially still be leveraged toward a different analysis (eg, for the estimate of walking heart rate as shown in this study). In particular, the variations in the research question time frame (eg, daily, nighttime, and weekly) can lead to different levels of required compliance. For example, to accurately estimate the average number of steps per day, we need a sufficient number of days with high wear time. However, for the example we used in Aim 2&#x2014;the estimation of walking heart rate&#x2014;we need a sufficient number of steps taken in a bout of walking by an individual. As such, we show in our example how an individual can have a large amount of walking data throughout an entire study while not having enough individual days with high wear time (<xref ref-type="fig" rid="figure5">Figure 5</xref>). These findings suggest that even samples with low compliance may still be useful for answering research questions. In this case, even a day with low wear time (ie, not a valid day) may contain several valid walks useful for estimating average walking heart rate.</p></sec><sec id="s4-2"><title>Secondary Findings</title><p>We also found that depending on whether one is interested in studying a population as a whole or the individuals within a population, the impact of wear time differed. For instance, in the student population, we observed only a small change in the estimated average daily step count in the population with the different methods of analysis (<xref ref-type="fig" rid="figure3">Figure 3</xref>). Depending on the objective of a study, that change could be negligible. However, if research is conducted to design a physical activity intervention or to evaluate the efficacy of an intervention, for example, the processing of an individual&#x2019;s data without the inclusion of wear time could lead to critical errors (<xref ref-type="fig" rid="figure4">Figure 4</xref>). In particular, if one considers the standard classification of participants into levels of physical activity (0&#x2010;5000 daily steps: sedentary; 5000&#x2010;7500: low active; 7500&#x2010;10,000: somewhat active; 10,000+: highly active) [<xref ref-type="bibr" rid="ref28">28</xref>], those errors can induce a misclassification. Ultimately, the intervention design or the evaluation of the intervention could be erroneous.</p><p>We quantified the phenomenon of wearables&#x2019; abandonment within our different populations (<xref ref-type="fig" rid="figure6">Figure 6</xref>). That phenomenon can potentially create a bias in results over time. For example, a monthly decrease in the population sample level of physical activity can be explained by an actual decline in people&#x2019;s movements or by the fact that participants were not wearing their sensors as much. An appropriate quantification of wear time in the analysis can potentially remove that bias.</p></sec><sec id="s4-3"><title>Comparison With Prior Work</title><p>While the literature on accelerometer usage presents various methodologies for accounting for wear time, it is essential to acknowledge that raw acceleration data or activity counts, typical outputs from accelerometers, are not available from consumer-grade wearables. Therefore, the strategies for considering wear time in the context of these devices necessitate their own approach. Consumer-grade wearables often offer summarized or processed data, which requires tailored methods for wear time analysis to ensure accurate and meaningful interpretation in research contexts. In general, research data on the analysis of wear time and compliance with consumer-grade wearables are sparse in the literature. Often, studies using consumer-grade wearables, such as smartwatches, rely on threshold-based methodologies for processing wear time [<xref ref-type="bibr" rid="ref13">13</xref>-<xref ref-type="bibr" rid="ref16">16</xref>]. However, these thresholds are often implemented without sufficient justification based on the specific dataset being analyzed and the research objectives.</p><p>Claudel et al [<xref ref-type="bibr" rid="ref17">17</xref>] developed a novel method to calculate wear time and determine a valid assessment day. Their proposed method calculated wear time using heart rate detection, step count, and the range of heart rate values. A valid day was defined as a day with more than 10 hours of wear time, with the removal of sleeping hours (from 11 PM to 5 AM). Claudel and colleagues present a structured and detailed methodology that can potentially be replicated for other studies. It highlights the importance of nighttime in wear time calculations and how researchers can conduct a sensitivity analysis to determine the impact of different nighttime limits on the outcome variables. Our study also demonstrates the potential impact of different calculations of wear time on parameter estimates. Both studies illustrate the importance of considering how the definition of a valid day may impact sample parameter estimates.</p><p>Studies have explored the factors that are related to compliance levels [<xref ref-type="bibr" rid="ref13">13</xref>]. The NetHealth study [<xref ref-type="bibr" rid="ref13">13</xref>] collected data from a student population using Fitbit devices and showed that some personality traits (eg, extraversion and openness) and Fitbit metrics (eg, minutes asleep and sedentary minutes) were related to compliance levels. Understanding the underlying reasons that may lead an individual to be more or less compliant can be useful in improving the overall wear time levels in these types of studies.</p><p>Another, perhaps more, direct way to increase compliance is through the use of incentives. There is a range of incentive models one can use to maintain compliance in longitudinal studies [<xref ref-type="bibr" rid="ref29">29</xref>]. Although improving compliance allows for parameter estimates to be less sensitive to wear time, it is difficult to imagine a &#x201C;one size fits all&#x201D; incentive model that would work on every single participant of a study. Thus, the analysis of wear time is likely to remain a crucial step in the analysis of consumer-grade wearables data to ensure accurate parameter estimates.</p></sec><sec id="s4-4"><title>Limitations</title><p>In the accelerometer literature, raw outputs from the sensors are most often used to determine wear time [<xref ref-type="bibr" rid="ref10">10</xref>,<xref ref-type="bibr" rid="ref11">11</xref>], which removes a layer of potential error. The outputs provided by Fitbit are processed (as opposed to raw) with unknown algorithms. Here, we assumed those outputs, and in particular minute-by-minute heart rate, were reliable and could be used to accurately estimate wear time. Claudel et al [<xref ref-type="bibr" rid="ref17">17</xref>] formulated a more complex wear time calculation algorithm fusing both heart rate detection and heart rate values revealing a potential overestimation of wear time when using heart rate detection only. Determining the most accurate estimate of wear time was beyond the scope of this study. However, further research should be conducted to validate methods for the calculation of wear time using the processed outputs of consumer-grade wearables as it may influence parameter estimates.</p><p>We assumed in Aim 2 that wear time was random. In other words, we assumed that participants did not choose a particular moment in their day to wear the device, which would bias the estimates of walking heart rate. However, this does not influence the conclusion of Aim 2, as we primarily focused on the amount of data needed to estimate a parameter with confidence, and not whether we could accurately estimate true walking heart rate.</p><p>It is important to note that the different datasets we used came from 2 different Fitbit devices (Fitbit Charge and Fitbit Inspire 2). It is possible that the versions of software and hardware are different between these 2 devices. Since the software information is proprietary information, we do not know whether the model differences impacted the used outputs. However, we expect and assume that the measurements between the 2 models are comparable and did not have a significant impact on our analysis.</p><p>Additionally, although we analyzed samples from different populations, our results may not translate to similar populations. First, each population sample was given a different set of instructions, which influenced their wear time. Second, Fitbit data syncing can be difficult and depends on the software used as well as the Fitbit model itself. Thus, the amount of data retrieved for the same population sample can be variable from one study to another. Finally, the different datasets used in this study were all collected during the COVID-19 pandemic, which may have affected the health-related behaviors of participants. We recommend that researchers conduct an analysis of wear time systematically when using sensing technologies to derive conclusions.</p></sec><sec id="s4-5"><title>Conclusions</title><p>One of the major benefits of leveraging fitness trackers is the potential to gain a unique and objective insight into an individual&#x2019;s natural behavior. However, if the analysis of wear time is not appropriately integrated into the data processing pipeline, that purported insight can become biased and imprecise, driving the results away from reality. Herein, we presented evidence of the critical impact of wear time on parameter estimates and how that impact may vary depending on the population sample, research question, study design (ie, incentives), and participant compliance. Future research could significantly benefit from our findings and methodological examples to incorporate the following recommendations: first, it is essential to conduct a thorough analysis of the wear time of the population in any given study that uses wearables, with particular attention to the data available when using consumer-grade wearables; second, it is equally important to systematically document and provide comprehensive details on that analysis. Our work provides quantitative data on the impact that different valid day definitions can have on sample parameter estimates in samples with varying wear time compliance.</p></sec></sec></body><back><ack><p>The Roadmap projects that leveraged the Fitbit wearable sensors across the pediatric oncology and college student populations were supported by the National Institute of Health and National Heart, Lung, and Blood Institute (grants 1R01HL146354 and K24HL156HL156896), the Edith S Briskin and Shirley K Schlafer Foundation, the University of Michigan Taubman Institute (Taubman Institute Innovation Project), and by a Scientific Research Initiative grant from the Biosciences Initiative of the University of Michigan Biosciences Initiative. The CareQOL JITAI project that used Fitbit wearable sensors across hematopoietic cell transplantation, spinal cord injury, and traumatic brain injury populations was supported by the following grants: R01NR013658 from the National Institutes of Health (NIH)/National Institute of Nursing Research; R01HL146354 and K24HL156896 from the National Heart, Lung and Blood Institute; and UL1TR002240 from the National Center for Advancing Translational Sciences. We are grateful to the investigators, coordinators, and research associates and assistants who worked on this study, the study participants, and organizations who supported recruitment efforts.</p></ack><fn-group><fn fn-type="conflict"><p>None declared.</p></fn></fn-group><glossary><title>Abbreviations</title><def-list><def-item><term id="abb1">bpm</term><def><p>beats per minute</p></def></def-item><def-item><term id="abb2">HCT</term><def><p>hematopoietic cell transplantation</p></def></def-item><def-item><term id="abb3">HD</term><def><p>Huntington disease</p></def></def-item><def-item><term id="abb4">SCI</term><def><p>spinal cord injury</p></def></def-item></def-list></glossary><ref-list><title>References</title><ref id="ref1"><label>1</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Harris</surname><given-names>TJ</given-names> </name><name name-style="western"><surname>Owen</surname><given-names>CG</given-names> </name><name name-style="western"><surname>Victor</surname><given-names>CR</given-names> </name><name name-style="western"><surname>Adams</surname><given-names>R</given-names> </name><name name-style="western"><surname>Ekelund</surname><given-names>U</given-names> </name><name name-style="western"><surname>Cook</surname><given-names>DG</given-names> </name></person-group><article-title>A comparison of questionnaire, accelerometer, and pedometer: measures in older people</article-title><source>Med Sci Sports Exerc</source><year>2009</year><month>07</month><volume>41</volume><issue>7</issue><fpage>1392</fpage><lpage>1402</lpage><pub-id pub-id-type="doi">10.1249/MSS.0b013e31819b3533</pub-id><pub-id pub-id-type="medline">19516162</pub-id></nlm-citation></ref><ref id="ref2"><label>2</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Beagle</surname><given-names>AJ</given-names> </name><name name-style="western"><surname>Tison</surname><given-names>GH</given-names> </name><name name-style="western"><surname>Aschbacher</surname><given-names>K</given-names> </name><name name-style="western"><surname>Olgin</surname><given-names>JE</given-names> </name><name name-style="western"><surname>Marcus</surname><given-names>GM</given-names> </name><name name-style="western"><surname>Pletcher</surname><given-names>MJ</given-names> </name></person-group><article-title>Comparison of the physical activity measured by a consumer wearable activity tracker and that measured by self-report: cross-sectional analysis of the health eHeart study</article-title><source>JMIR Mhealth Uhealth</source><year>2020</year><month>12</month><day>29</day><volume>8</volume><issue>12</issue><fpage>e22090</fpage><pub-id pub-id-type="doi">10.2196/22090</pub-id><pub-id pub-id-type="medline">33372896</pub-id></nlm-citation></ref><ref id="ref3"><label>3</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Wright</surname><given-names>R</given-names> </name><name name-style="western"><surname>Keith</surname><given-names>L</given-names> </name></person-group><article-title>Wearable technology: if the tech fits, wear it</article-title><source>J Electron Resour Med Libr</source><year>2014</year><month>10</month><day>2</day><volume>11</volume><issue>4</issue><fpage>204</fpage><lpage>216</lpage><pub-id pub-id-type="doi">10.1080/15424065.2014.969051</pub-id></nlm-citation></ref><ref id="ref4"><label>4</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Lymberis</surname><given-names>A</given-names> </name><name name-style="western"><surname>Dittmar</surname><given-names>A</given-names> </name></person-group><article-title>Advanced wearable health systems and applications</article-title><source>IEEE Eng Med Biol Mag</source><year>2007</year><volume>26</volume><issue>3</issue><fpage>29</fpage><lpage>33</lpage><pub-id pub-id-type="doi">10.1109/memb.2007.364926</pub-id><pub-id pub-id-type="medline">17549917</pub-id></nlm-citation></ref><ref id="ref5"><label>5</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tr&#x00F6;ster</surname><given-names>G</given-names> </name></person-group><article-title>The agenda of wearable healthcare</article-title><source>Yearb Med Inform</source><year>2005</year><volume>14</volume><issue>1</issue><fpage>125</fpage><lpage>138</lpage><pub-id pub-id-type="doi">10.1055/s-0038-1638446</pub-id><pub-id pub-id-type="medline">27706307</pub-id></nlm-citation></ref><ref id="ref6"><label>6</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bravata</surname><given-names>DM</given-names> </name><name name-style="western"><surname>Smith-Spangler</surname><given-names>C</given-names> </name><name name-style="western"><surname>Sundaram</surname><given-names>V</given-names> </name><etal/></person-group><article-title>Using pedometers to increase physical activity and improve health: a systematic review</article-title><source>JAMA</source><year>2007</year><month>11</month><day>21</day><volume>298</volume><issue>19</issue><fpage>2296</fpage><lpage>2304</lpage><pub-id pub-id-type="doi">10.1001/jama.298.19.2296</pub-id><pub-id pub-id-type="medline">18029834</pub-id></nlm-citation></ref><ref id="ref7"><label>7</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Steinhubl</surname><given-names>SR</given-names> </name><name name-style="western"><surname>Muse</surname><given-names>ED</given-names> </name><name name-style="western"><surname>Topol</surname><given-names>EJ</given-names> </name></person-group><article-title>Can mobile health technologies transform health care?</article-title><source>JAMA</source><year>2013</year><month>12</month><day>11</day><volume>310</volume><issue>22</issue><fpage>2395</fpage><lpage>2396</lpage><pub-id pub-id-type="doi">10.1001/jama.2013.281078</pub-id><pub-id pub-id-type="medline">24158428</pub-id></nlm-citation></ref><ref id="ref8"><label>8</label><nlm-citation citation-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Lazar</surname><given-names>A</given-names> </name><name name-style="western"><surname>Koehler</surname><given-names>C</given-names> </name><name name-style="western"><surname>Tanenbaum</surname><given-names>TJ</given-names> </name><name name-style="western"><surname>Nguyen</surname><given-names>DH</given-names> </name></person-group><article-title>Why we use and abandon smart devices</article-title><source>Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp &#x2019;15)</source><publisher-name>Association for Computing Machinery</publisher-name><fpage>635</fpage><lpage>646</lpage><pub-id pub-id-type="doi">10.1145/2750858.2804288</pub-id></nlm-citation></ref><ref id="ref9"><label>9</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Catellier</surname><given-names>DJ</given-names> </name><name name-style="western"><surname>Hannan</surname><given-names>PJ</given-names> </name><name name-style="western"><surname>Murray</surname><given-names>DM</given-names> </name><etal/></person-group><article-title>Imputation of missing data when measuring physical activity by accelerometry</article-title><source>Med Sci Sports Exerc</source><year>2005</year><month>11</month><volume>37</volume><issue>11 Suppl</issue><fpage>S555</fpage><lpage>S562</lpage><pub-id pub-id-type="doi">10.1249/01.mss.0000185651.59486.4e</pub-id><pub-id pub-id-type="medline">16294118</pub-id></nlm-citation></ref><ref id="ref10"><label>10</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Herrmann</surname><given-names>SD</given-names> </name><name name-style="western"><surname>Barreira</surname><given-names>TV</given-names> </name><name name-style="western"><surname>Kang</surname><given-names>M</given-names> </name><name name-style="western"><surname>Ainsworth</surname><given-names>BE</given-names> </name></person-group><article-title>How many hours are enough? Accelerometer wear time may provide bias in daily activity estimates</article-title><source>J Phys Act Health</source><year>2013</year><month>07</month><volume>10</volume><issue>5</issue><fpage>742</fpage><lpage>749</lpage><pub-id pub-id-type="doi">10.1123/jpah.10.5.742</pub-id><pub-id pub-id-type="medline">23036822</pub-id></nlm-citation></ref><ref id="ref11"><label>11</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Rich</surname><given-names>C</given-names> </name><name name-style="western"><surname>Geraci</surname><given-names>M</given-names> </name><name name-style="western"><surname>Griffiths</surname><given-names>L</given-names> </name><name name-style="western"><surname>Sera</surname><given-names>F</given-names> </name><name name-style="western"><surname>Dezateux</surname><given-names>C</given-names> </name><name name-style="western"><surname>Cortina-Borja</surname><given-names>M</given-names> </name></person-group><article-title>Quality control methods in accelerometer data processing: defining minimum wear time</article-title><source>PLoS One</source><year>2013</year><volume>8</volume><issue>6</issue><fpage>e67206</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0067206</pub-id><pub-id pub-id-type="medline">23826236</pub-id></nlm-citation></ref><ref id="ref12"><label>12</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>McCarthy</surname><given-names>M</given-names> </name><name name-style="western"><surname>Bury</surname><given-names>DP</given-names> </name><name name-style="western"><surname>Byrom</surname><given-names>B</given-names> </name><name name-style="western"><surname>Geoghegan</surname><given-names>C</given-names> </name><name name-style="western"><surname>Wong</surname><given-names>S</given-names> </name></person-group><article-title>Determining minimum wear time for mobile sensor technology</article-title><source>Ther Innov Regul Sci</source><year>2021</year><month>01</month><volume>55</volume><issue>1</issue><fpage>33</fpage><lpage>37</lpage><pub-id pub-id-type="doi">10.1007/s43441-020-00187-3</pub-id><pub-id pub-id-type="medline">32588369</pub-id></nlm-citation></ref><ref id="ref13"><label>13</label><nlm-citation citation-type="book"><person-group person-group-type="author"><name name-style="western"><surname>Faust</surname><given-names>L</given-names> </name><name name-style="western"><surname>Purta</surname><given-names>R</given-names> </name><name name-style="western"><surname>Hachen</surname><given-names>D</given-names> </name><etal/></person-group><article-title>Exploring compliance: observations from a large scale Fitbit study</article-title><source>Proceedings of the 2nd International Workshop on Social Sensing (SocialSens&#x2019;17)</source><publisher-name>Association for Computing Machinery</publisher-name><fpage>55</fpage><lpage>60</lpage><pub-id pub-id-type="doi">10.1145/3055601.3055608</pub-id></nlm-citation></ref><ref id="ref14"><label>14</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Hardcastle</surname><given-names>SJ</given-names> </name><name name-style="western"><surname>Jim&#x00E9;nez-Castuera</surname><given-names>R</given-names> </name><name name-style="western"><surname>Maxwell-Smith</surname><given-names>C</given-names> </name><name name-style="western"><surname>Bulsara</surname><given-names>MK</given-names> </name><name name-style="western"><surname>Hince</surname><given-names>D</given-names> </name></person-group><article-title>Fitbit wear-time and patterns of activity in cancer survivors throughout a physical activity intervention and follow-up: exploratory analysis from a randomised controlled trial</article-title><source>PLoS One</source><year>2020</year><volume>15</volume><issue>10</issue><fpage>e0240967</fpage><pub-id pub-id-type="doi">10.1371/journal.pone.0240967</pub-id><pub-id pub-id-type="medline">33075100</pub-id></nlm-citation></ref><ref id="ref15"><label>15</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Giurgiu</surname><given-names>M</given-names> </name><name name-style="western"><surname>Timm</surname><given-names>I</given-names> </name><name name-style="western"><surname>Becker</surname><given-names>M</given-names> </name><etal/></person-group><article-title>Quality evaluation of free-living validation studies for the assessment of 24-hour physical behavior in adults via wearables: systematic review</article-title><source>JMIR Mhealth Uhealth</source><year>2022</year><month>06</month><day>9</day><volume>10</volume><issue>6</issue><fpage>e36377</fpage><pub-id pub-id-type="doi">10.2196/36377</pub-id><pub-id pub-id-type="medline">35679106</pub-id></nlm-citation></ref><ref id="ref16"><label>16</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Giurgiu</surname><given-names>M</given-names> </name><name name-style="western"><surname>Kolb</surname><given-names>S</given-names> </name><name name-style="western"><surname>Nigg</surname><given-names>C</given-names> </name><etal/></person-group><article-title>Assessment of 24-hour physical behaviour in children and adolescents via wearables: a systematic review of free-living validation studies</article-title><source>BMJ Open Sport Exerc Med</source><year>2022</year><volume>8</volume><issue>2</issue><fpage>e001267</fpage><pub-id pub-id-type="doi">10.1136/bmjsem-2021-001267</pub-id><pub-id pub-id-type="medline">35646389</pub-id></nlm-citation></ref><ref id="ref17"><label>17</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Claudel</surname><given-names>SE</given-names> </name><name name-style="western"><surname>Tamura</surname><given-names>K</given-names> </name><name name-style="western"><surname>Troendle</surname><given-names>J</given-names> </name><etal/></person-group><article-title>Comparing methods to identify wear-time intervals for physical activity with the Fitbit Charge 2</article-title><source>J Aging Phys Act</source><year>2021</year><month>06</month><day>1</day><volume>29</volume><issue>3</issue><fpage>529</fpage><lpage>535</lpage><pub-id pub-id-type="doi">10.1123/japa.2020-0059</pub-id><pub-id pub-id-type="medline">33326935</pub-id></nlm-citation></ref><ref id="ref18"><label>18</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Carlozzi</surname><given-names>NE</given-names> </name><name name-style="western"><surname>Choi</surname><given-names>SW</given-names> </name><name name-style="western"><surname>Wu</surname><given-names>Z</given-names> </name><etal/></person-group><article-title>An app-based just-in-time adaptive self-management intervention for care partners (CareQOL): protocol for a pilot trial</article-title><source>JMIR Res Protoc</source><year>2021</year><month>12</month><day>9</day><volume>10</volume><issue>12</issue><fpage>e32842</fpage><pub-id pub-id-type="doi">10.2196/32842</pub-id><pub-id pub-id-type="medline">34889775</pub-id></nlm-citation></ref><ref id="ref19"><label>19</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Cislo</surname><given-names>C</given-names> </name><name name-style="western"><surname>Clingan</surname><given-names>C</given-names> </name><name name-style="western"><surname>Gilley</surname><given-names>K</given-names> </name><etal/></person-group><article-title>Monitoring beliefs and physiological measures in students at risk for COVID-19 using wearable sensors and smartphone technology: protocol for a mobile health study</article-title><source>JMIR Res Protoc</source><year>2021</year><month>06</month><day>4</day><volume>10</volume><issue>6</issue><fpage>1</fpage><lpage>9</lpage><pub-id pub-id-type="doi">10.2196/29561</pub-id><pub-id pub-id-type="medline">34115607</pub-id></nlm-citation></ref><ref id="ref20"><label>20</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Koblick</surname><given-names>SB</given-names> </name><name name-style="western"><surname>Yu</surname><given-names>M</given-names> </name><name name-style="western"><surname>DeMoss</surname><given-names>M</given-names> </name><etal/></person-group><article-title>A pilot intervention of using a mobile health app (ONC Roadmap) to enhance health-related quality of life in family caregivers of pediatric patients with cancer</article-title><source>Mhealth</source><year>2023</year><volume>9</volume><fpage>5</fpage><pub-id pub-id-type="doi">10.21037/mhealth-22-24</pub-id><pub-id pub-id-type="medline">36760786</pub-id></nlm-citation></ref><ref id="ref21"><label>21</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kruskal</surname><given-names>WH</given-names> </name><name name-style="western"><surname>Wallis</surname><given-names>WA</given-names> </name></person-group><article-title>Use of ranks in one-criterion variance analysis</article-title><source>J Am Stat Assoc</source><year>1952</year><month>12</month><volume>47</volume><issue>260</issue><fpage>583</fpage><lpage>621</lpage><pub-id pub-id-type="doi">10.1080/01621459.1952.10483441</pub-id></nlm-citation></ref><ref id="ref22"><label>22</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Dunn</surname><given-names>OJ</given-names> </name></person-group><article-title>Multiple comparisons among means</article-title><source>J Am Stat Assoc</source><year>1961</year><month>03</month><volume>56</volume><issue>293</issue><fpage>52</fpage><lpage>64</lpage><pub-id pub-id-type="doi">10.1080/01621459.1961.10482090</pub-id></nlm-citation></ref><ref id="ref23"><label>23</label><nlm-citation citation-type="web"><article-title>Fitbit data processing</article-title><source>GitHub</source><access-date>2025-01-29</access-date><comment><ext-link ext-link-type="uri" xlink:href="https://github.com/Loubna-brd/Fitbit_data_processing">https://github.com/Loubna-brd/Fitbit_data_processing</ext-link></comment></nlm-citation></ref><ref id="ref24"><label>24</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Bassett</surname><given-names>DR</given-names> </name><name name-style="western"><surname>Toth</surname><given-names>LP</given-names> </name><name name-style="western"><surname>LaMunion</surname><given-names>SR</given-names> </name><name name-style="western"><surname>Crouter</surname><given-names>SE</given-names> </name></person-group><article-title>Step counting: a review of measurement considerations and health-related applications</article-title><source>Sports Med</source><year>2017</year><month>07</month><volume>47</volume><issue>7</issue><fpage>1303</fpage><lpage>1315</lpage><pub-id pub-id-type="doi">10.1007/s40279-016-0663-1</pub-id></nlm-citation></ref><ref id="ref25"><label>25</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Kraus</surname><given-names>WE</given-names> </name><name name-style="western"><surname>Janz</surname><given-names>KF</given-names> </name><name name-style="western"><surname>Powell</surname><given-names>KE</given-names> </name><etal/></person-group><article-title>Daily step counts for measuring physical activity exposure and its relation to health</article-title><source>Med Sci Sports Exerc</source><year>2019</year><month>06</month><volume>51</volume><issue>6</issue><fpage>1206</fpage><lpage>1212</lpage><pub-id pub-id-type="doi">10.1249/MSS.0000000000001932</pub-id><pub-id pub-id-type="medline">31095077</pub-id></nlm-citation></ref><ref id="ref26"><label>26</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Wang</surname><given-names>C</given-names> </name><name name-style="western"><surname>Lizardo</surname><given-names>O</given-names> </name><name name-style="western"><surname>Hachen</surname><given-names>DS</given-names> </name></person-group><article-title>Using Fitbit data to monitor the heart rate evolution patterns of college students</article-title><source>J Am Coll Health</source><year>2022</year><month>04</month><day>3</day><volume>70</volume><issue>3</issue><fpage>875</fpage><lpage>882</lpage><pub-id pub-id-type="doi">10.1080/07448481.2020.1775610</pub-id></nlm-citation></ref><ref id="ref27"><label>27</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tudor-Locke</surname><given-names>C</given-names> </name><name name-style="western"><surname>Rowe</surname><given-names>DA</given-names> </name></person-group><article-title>Using cadence to study free-living ambulatory behaviour</article-title><source>Sports Med</source><year>2012</year><month>05</month><volume>42</volume><issue>5</issue><fpage>381</fpage><lpage>398</lpage><pub-id pub-id-type="doi">10.2165/11599170-000000000-00000</pub-id></nlm-citation></ref><ref id="ref28"><label>28</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Tudor-Locke</surname><given-names>C</given-names> </name><name name-style="western"><surname>Bassett</surname><given-names>DR</given-names> </name></person-group><article-title>How many steps/day are enough?</article-title><source>Sports Med</source><year>2004</year><volume>34</volume><issue>1</issue><fpage>1</fpage><lpage>8</lpage><pub-id pub-id-type="doi">10.2165/00007256-200434010-00001</pub-id></nlm-citation></ref><ref id="ref29"><label>29</label><nlm-citation citation-type="journal"><person-group person-group-type="author"><name name-style="western"><surname>Jaimes</surname><given-names>LG</given-names> </name><name name-style="western"><surname>Vergara-Laurens</surname><given-names>IJ</given-names> </name><name name-style="western"><surname>Raij</surname><given-names>A</given-names> </name></person-group><article-title>A survey of incentive techniques for mobile crowd sensing</article-title><source>IEEE Internet Things J</source><year>2015</year><volume>2</volume><issue>5</issue><fpage>370</fpage><lpage>380</lpage><pub-id pub-id-type="doi">10.1109/JIOT.2015.2409151</pub-id></nlm-citation></ref></ref-list></back></article>