TY - JOUR AU - Faqar Uz Zaman, Sara Fatima AU - Sliwinski, Svenja AU - Mohr-Wetzel, Lisa AU - Dreilich, Julia AU - Filmann, Natalie AU - Detemble, Charlotte AU - Zmuc, Dora AU - Chun, Felix AU - Derwich, Wojciech AU - Schreiner, Waldemar AU - Bechstein, Wolf AU - Fleckenstein, Johannes AU - Schnitzbauer, Andreas A PY - 2025 DA - 2025/2/10 TI - Validity, Accuracy, and Safety Assessment of an Aerobic Interval Training Using an App-Based Prehabilitation Program (PROTEGO MAXIMA Trial) Before Major Surgery: Prospective, Interventional Pilot Study JO - JMIR Mhealth Uhealth SP - e55298 VL - 13 KW - digital health KW - prehab KW - major surgery KW - surgical oncology KW - smartwatches KW - safety and quality KW - surgery KW - surgical KW - oncology KW - validity KW - accuracy KW - safety management KW - management KW - aerobic KW - aerobic training KW - app KW - prehabilitation KW - pilot study KW - quality of life KW - medical device KW - wearable KW - wearables KW - heart rate AB - Background: Major surgery is associated with significant morbidity and a reduced quality of life, particularly among older adults and individuals with frailty and impaired functional capacity. Multimodal prehabilitation can enhance functional recovery after surgery and reduce postoperative complications. Digital prehabilitation has the potential to be a resource-sparing and patient-empowering tool that improves patients’ preoperative status; however, little remains known regarding their safety and accuracy as medical devices. Objective: This study aims to test the accuracy and validity of a new software in comparison to the gold-standard electrocardiogram (ECG)-based heart rate measurement. Methods: The PROTEGO MAXIMA trial was a prospective interventional pilot trial assessing the validity, accuracy, and safety of an app-based exercise program. The Prehab App calculates a personalized, risk-stratified aerobic interval training plan based on individual risk factors and utilizes wearables to monitor heart rate. Healthy students and patients undergoing major surgery were enrolled. A structured risk assessment was conducted, followed by a 6-minute walking test and a 37-minute supervised interval session. During the exercise, patients wore app-linked wearables for heart rate and distance measurements, which were compared with standard ECG and treadmill measurements. Safety, accuracy, and usability assessments included testing alarm signals, while the occurrence of adverse events served as the primary and secondary outcome measures. Results: A total of 75 participants were included. The mean heart rate differences between wearables and standard ECG were ≤5 bpm (beats per minute) with a mean absolute percentage error of ≤5%. Regression analysis revealed a significant impact of the BMI (odds ratio 0.90, 95% CI 0.82-0.98, P=.02) and Timed Up and Go Test score (odds ratio 0.12, 95% CI 0.03-0.55, P=.006) on the accuracy of heart rate measurement; 29 (39%) patients experienced adverse events: pain (5/12, 42%), ECG electrode–related skin irritations (2/42, 17%), dizziness (2/42, 17%), shortness of breath (2/42, 17%), and fatigue (1/42, 8%). No cardiovascular or serious adverse events were reported, and no serious device deficiency was detected. There were no indications of clinically meaningful overexertion based on laboratory values measured before and after the 6-minute walking test and exercise. The differences in means and ranges were as follows: lactate (mmol/l), mean 0.04 (range –3 to 6; P=.47); creatinine kinase (U/l), mean 12 (range –7 to 43; P<.001); and sodium (mmol/l), mean –2 (range –11 to 12; P<.001). Conclusions: The interventional trial demonstrated the high safety of the exercise program and the accuracy of heart rate measurements using commercial wearables in patients before major surgery, paving the way for potential remote implementation in the future. Trial Registration: German Clinical Trials Register DRKS00026985; https://drks.de/search/en/trial/DRKS00026985 and European Database on Medical Devices (EUDAMED) CIV-21-07-0307311. International Registered Report Identifier (IRRID): RR2-10.1136/bmjopen-2022-069394 SN - 2291-5222 UR - https://mhealth.jmir.org/2025/1/e55298 UR - https://doi.org/10.2196/55298 DO - 10.2196/55298 ID - info:doi/10.2196/55298 ER -