TY - JOUR AU - Pitman, Bradley M AU - Chew, Sok-Hui AU - Wong, Christopher X AU - Jaghoori, Amenah AU - Iwai, Shinsuke AU - Thomas, Gijo AU - Chew, Andrew AU - Sanders, Prashanthan AU - Lau, Dennis H PY - 2021 DA - 2021/5/19 TI - Performance of a Mobile Single-Lead Electrocardiogram Technology for Atrial Fibrillation Screening in a Semirural African Population: Insights From “The Heart of Ethiopia: Focus on Atrial Fibrillation” (TEFF-AF) Study JO - JMIR Mhealth Uhealth SP - e24470 VL - 9 IS - 5 KW - atrial fibrillation KW - screening KW - sub-Saharan Africa KW - single-lead ECG AB - Background: Atrial fibrillation (AF) screening using mobile single-lead electrocardiogram (ECG) devices has demonstrated variable sensitivity and specificity. However, limited data exists on the use of such devices in low-resource countries. Objective: The goal of the research was to evaluate the utility of the KardiaMobile device’s (AliveCor Inc) automated algorithm for AF screening in a semirural Ethiopian population. Methods: Analysis was performed on 30-second single-lead ECG tracings obtained using the KardiaMobile device from 1500 TEFF-AF (The Heart of Ethiopia: Focus on Atrial Fibrillation) study participants. We evaluated the performance of the KardiaMobile automated algorithm against cardiologists’ interpretations of 30-second single-lead ECG for AF screening. Results: A total of 1709 single-lead ECG tracings (including repeat tracing on 209 occasions) were analyzed from 1500 Ethiopians (63.53% [953/1500] male, mean age 35 [SD 13] years) who presented for AF screening. Initial successful rhythm decision (normal or possible AF) with one single-lead ECG tracing was lower with the KardiaMobile automated algorithm versus manual verification by cardiologists (1176/1500, 78.40%, vs 1455/1500, 97.00%; P<.001). Repeat single-lead ECG tracings in 209 individuals improved overall rhythm decision, but the KardiaMobile automated algorithm remained inferior (1301/1500, 86.73%, vs 1479/1500, 98.60%; P<.001). The key reasons underlying unsuccessful KardiaMobile automated rhythm determination include poor quality/noisy tracings (214/408, 52.45%), frequent ectopy (22/408, 5.39%), and tachycardia (>100 bpm; 167/408, 40.93%). The sensitivity and specificity of rhythm decision using KardiaMobile automated algorithm were 80.27% (1168/1455) and 82.22% (37/45), respectively. Conclusions: The performance of the KardiaMobile automated algorithm was suboptimal when used for AF screening. However, the KardiaMobile single-lead ECG device remains an excellent AF screening tool with appropriate clinician input and repeat tracing. Trial Registration: Australian New Zealand Clinical Trials Registry ACTRN12619001107112; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=378057&isReview=true SN - 2291-5222 UR - https://mhealth.jmir.org/2021/5/e24470 UR - https://doi.org/10.2196/24470 UR - http://www.ncbi.nlm.nih.gov/pubmed/34009129 DO - 10.2196/24470 ID - info:doi/10.2196/24470 ER -