Published on in Vol 5, No 2 (2017): February

Authors’ Reply to: Critique of “Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions” – Does Location of the Device Matter?

Authors’ Reply to: Critique of “Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions” – Does Location of the Device Matter?

Authors’ Reply to: Critique of “Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions” – Does Location of the Device Matter?

Letter to the Editor

1University of Delaware, Department of Behavioral Health and Nutrition, University of Delaware, Newark, DE, United States

2Northern Arizona University, Informatics and Computing Program, Northern Arizona University, Flagstaff, AZ, United States

3University of Delaware, Biostatistics Core Facility, University of Delaware, Newark, DE, United States

Corresponding Author:

Gregory M Dominick, PhD.

University of Delaware

Department of Behavioral Health and Nutrition

University of Delaware

023 Carpenter Sports Building

26 North College Avenue

Newark, DE, 19716

United States

Phone: 1 302 831 3672

Fax:1 302 831 4261

Email: gdominic@udel.edu



My co-authors and I thank Dr. Migueles and colleagues for their letter to the editor [1] regarding our recent JMIR mHealth and UHealth manuscript [2]. We welcome the opportunity to address the matters raised. 

In regard to the core critique that divergent placement of the ActiGraph and Fitbit devices (hip and wrist, respectively) confounds data interpretation in our investigation is limited, given that the methods and subsequent data interpretation were informed by the literature available at the time the study was conducted in 2014. Whereas the ActiGraph GT3X device can be worn on the wrist, the algorithms and cut-point thresholds currently available in the ActiLife software are valid only when the device is worn at the hip. Our study examined the measurement congruence between the first-available, wrist-worn Fitbit device (Flex) and the “gold standard,” waist-worn ActiGraph GT3X, in which we employed a longer assessment period (14 days) within free-living conditions that included average day- and minute-level activity, and which also comprised a range of self-reported bouts of exercise. Because our study used ActiGraph as the criterion measure for device comparison, it would have been methodologically inappropriate to place the device on the wrist. 

Both ActiGraph and Fitbit provide a proxy for the actual movements and activities of the subject as they occur in the natural environment.  Given that the hip-worn ActiGraph algorithms and cut points are benchmarked against direct clinical observations, [3,4] our study examined the ability of the wrist-worn Fitbit Flex to assess physical activity as compared to the validated estimates provided by ActiGraph within free-living conditions. Hence, this line of research continues to be tethered to evaluations that are akin to comparing “apples to oranges” in the generalized case.

Indeed, research has recently begun to utilize raw acceleration signals for developing improved algorithms for hip and wrist-worn accelerometers [5-7] that also include ActiGraph devices [8,9]. Case in point, population-based health surveillance systems such as the National Health Examination Survey (NHANES) are using raw acceleration signals to process activity data [10]. However, to date there is no consensus, regarding the use of raw acceleration signals to quantify activity or how to explicitly process data from raw signals [9]. Furthermore, it is not currently possible to access raw acceleration data from the Fitbit device; researchers must rely on activity counts determined by the proprietary algorithms used by Fitbit. Thus, the comparison of apples to oranges remains unavoidable at this point in time and as such there is robust empirical precedent for our study design [11-14]. 

Our study utilized a collective methodological approach founded on end-user practicality, but evolving toward a more scientifically appropriate means of comparison within truly free-living conditions. With this understanding, and more recent evidence supporting the use of raw acceleration signals [6,8-10], we were forthcoming in the manuscript when we highlighted the limitations of our study. Accordingly, we recommended that future studies use accelerometers that are placed on a common location. Yet, this will ultimately require some standardized process for determining what wrist-worn accelerometer algorithms to use as well as, identifying approaches to access raw acceleration signals from Fitbit. Other approaches currently being examined by our group include modeling the physical activity measures of the ActiGraph GT3X using Fitbit-derived measures of intensity, steps, and calories, and analyzing the implications of how modeling impacts bout assessment differences between the devices.

To summarize the discussion points, off-the-shelf- and research-grade physical activity monitor use continues to evolve. Our original study design, at the heart of the current discussion, was congruent with then modern scientific methods balanced with end user practicality. As such, our study serves as a research foundation to inform future research directions rather than maintain the status-quo. Our group, and presumably Migueles et al are, are part of a research collective working to better understand and quantify physical activity in a self-correcting fashion that emergent science has always followed and we value the perspective of those who share this vision. By having these discussions, we will collectively move this science forward.

Conflicts of Interest

None declared.

  1. Migueles JH, Cadenas-Sanchez C, Ortega FB. Critique of: “Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions”. JMIR Mhealth Uhealth 2017;5(2):e15. [CrossRef]
  2. Dominick GM, Winfree KN, Pohlig RT, Papas MA. Physical Activity Assessment Between Consumer- and Research-Grade Accelerometers: A Comparative Study in Free-Living Conditions. JMIR Mhealth Uhealth 2016 Sep 19;4(3):e110 [FREE Full text] [CrossRef] [Medline]
  3. Kozey-Keadle S, Libertine A, Lyden K, Staudenmayer J, Freedson PS. Validation of wearable monitors for assessing sedentary behavior. Med Sci Sports Exerc 2011;43(8):1561-1567. [CrossRef]
  4. Sasaki JE, John D, Freedson PS. Validation and comparison of ActiGraph activity monitors. J Sci Med Sport 2011 Sep;14(5):411-416. [CrossRef] [Medline]
  5. Esliger DW, Rowlands AV, Hurst TL, Catt M, Murray P, Eston RG. Validation of the GENEA Accelerometer. Med Sci Sports Exerc 2011 Jun;43(6):1085-1093. [CrossRef] [Medline]
  6. Hildebrand M, Hansen BH, Ekelund U. Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors. Med Sci Sports Exerc 2014;46(9):1816-1824. [CrossRef]
  7. Zhang S, Rowlands AV, Murray P, Hurst TL. Physical activity classification using the GENEA wrist-worn accelerometer. Med Sci Sports Exerc 2012 Apr;44(4):742-748. [CrossRef] [Medline]
  8. Ellis K, Kerr J, Godbole S, Staudenmayer J, Lanckriet G. Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification. Med Sci Sports Exerc 2016;48(5):933-940. [CrossRef]
  9. Staudenmayer J, He S, Hickey A, Sasaki J, Freedson P. Methods to estimate aspects of physical activity and sedentary behavior from high-frequency wrist accelerometer measurements. J Appl Physiol 2015 Jun 25;119(4):396-403. [CrossRef] [Medline]
  10. Kim J, Im JS, Choi YH. Objectively measured sedentary behavior and moderate-to-vigorous physical activity on the health-related quality of life in US adults: The National Health and Nutrition Examination Survey 2003-2006. Qual Life Res 2016 Nov 11. [CrossRef] [Medline]
  11. Alharbi M, Bauman A, Neubeck L, Gallagher R. Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population. Eur J Prev Cardiol 2016 Sep;23(14):1476-1485. [CrossRef] [Medline]
  12. Ferguson T, Rowlands AV, Olds T, Maher C. The validity of consumer-level, activity monitors in healthy adults worn in free-living conditions: a cross-sectional study. Int J Behav Nutr Phys Act 2015 Mar 27;12:42 [FREE Full text] [CrossRef] [Medline]
  13. Nelson MB, Kaminsky LA, Dickin DC, Montoye Alexander H K. Validity of Consumer-Based Physical Activity Monitors for Specific Activity Types. Med Sci Sports Exerc 2016 Aug;48(8):1619-1628. [CrossRef] [Medline]
  14. Kooiman Thea J M, Dontje ML, Sprenger SR, Krijnen WP, van der Schans Cees P, de Groot M. Reliability and validity of ten consumer activity trackers. BMC Sports Sci Med Rehabil 2015;7:24 [FREE Full text] [CrossRef] [Medline]

Edited by G Eysenbach; This is a non–peer-reviewed article. submitted 26.01.17; accepted 27.01.17; published 27.02.17

Copyright

©Gregory M. Dominick, Kyle N. Winfree, Ryan T. Pohlig, Mia A. Papas. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 27.02.2017.

This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.