Review
Abstract
Background: Assessing fall risk, especially in individuals with neurological disorders, is essential to prevent hospitalization, hypomobility, and reduced functional independence. Wearable sensors are increasingly used in neurorehabilitation, as they enable unsupervised fall risk assessment by providing continuous monitoring during daily functional tasks, thereby offering a reflection of the individual’s real-world fall risk.
Objective: We systematically reviewed the literature on reliable biomechanical gait parameters detected with wearable sensors to assess fall risk in neurological disorders, focusing on patients with Parkinson disease, multiple sclerosis, stroke, or Alzheimer disease. In addition, we examined the latest advancements in wearable sensor technology, including best practices for device placement as well as data processing and analysis.
Methods: We conducted a comprehensive systematic search for relevant peer-reviewed articles published up to April 18, 2025, using PubMed, Web of Science, Embase, and IEEE Xplore, which are the most used databases in the fields of health and bioengineering.
Results: The 19 included studies involved 2630 patients with neurological disorders, including 226 (8.59%) with multiple sclerosis (n=7, 37% studies), 2305 (87.64%) with Parkinson disease (n=8, 53% studies), 51 (1.94%) with stroke (n=3, 16% studies), and 48 (1.83%) with Alzheimer disease or cognitive impairment (n=1, 5% study).
Conclusions: This review highlights the role of wearable technologies in assessing fall risk in patients with neurological disorders. Although the included studies showed variation in methods and a focus on technology over clinical context, the lack of standardization reflects ongoing advancements, which may be seen as a strength.
Trial Registration: PROSPERO CRD42023463944; https://www.crd.york.ac.uk/PROSPERO/view/CRD42023463944
doi:10.2196/67265
Keywords
Introduction
Background
Neurological disorders, such as Parkinson disease (PD), multiple sclerosis (MS), Alzheimer disease (AD), and stroke, are significant and growing global health concerns due to their high prevalence. A recent meta-analysis reported a global pooled prevalence of PD of 1.51 cases per 1000 individuals, with higher rates observed among male individuals and a significant increase over the past 4 decades []. Similarly, MS currently affects approximately 2.8 million people globally, with rising prevalence and incidence trends observed worldwide []. In Europe, the prevalence of AD has been estimated at 5.05% (95% CI 4.73%-5.39%) []. The incidence of clinically diagnosed AD per 1000 person-years increases markedly with age: 3.4 for individuals aged 65 to 74 years, 13.8 for those aged 75 to 84 years, and 35.8 for those aged ≥85 years [,]. Regarding cerebrovascular impairments, stroke continues to be a leading cause of death and disability, with >12 million new cases per year and >100 million survivors of stroke worldwide [].
These conditions often lead to alterations in gait and balance, increasing the risk of falls. This risk is especially pronounced in older adults and individuals with neurological impairments. Approximately one-third of adults aged >65 years experience a fall each year [], and this rate rises to nearly 50% among those aged >80 years []. Consequently, falls in this patient population considered fragile can worsen quality of life due to hospitalization, hypomobility, and reduced functional independence []. Fall-related injuries not only entail substantial medical costs but also determine patients’ mortality risk. Among neurological disorders, PD, MS, cerebrovascular accidents, and AD are among the most common, causing significant motor disability. It is noteworthy that these patients with neurological disorders are considered recurrent fallers due to their gait features. In particular, it is estimated that 39% of patients with PD experience falls, while 40% to 60% of patients with MS experience recurrent falls []. Similarly, patients with stroke are at high risk for falls, with fall frequencies ranging from 27% to 39% in rehabilitation hospitals []. Furthermore, older adults with AD are more than twice as likely to experience a fall compared to cognitively healthy peers, with rates ranging from 60% to 80% []. However, each neurological disorder is characterized by considerable heterogeneity in gait disturbances due to differences in underlying etiology []; for example, neurodegenerative disorders (such as PD, MS, and AD) are associated with distinct gait patterns, characterized by reduced gait speed, shorter step length, and increased muscle weakness []. In addition, ambulation in patients with PD is characterized by shorter steps, loss of dissociated arm and trunk movements during gait, and postural instability []. By contrast, patients with MS manifest pathological gait features related to spasticity, ataxia, muscle weakness, and sensory and proprioceptive deficits, all of which contribute to progressive disability []. AD independently increases fall risk due to its associated impairments in judgment, gait, visuospatial perception, and hazard recognition []. Differently from neurodegenerative disorders, patients with stroke are characterized by a marked spatiotemporal asymmetry between steps, which substantially increases fall risk []. For these reasons, gait and balance assessment in patients with neurological disorders is essential in all phases of the rehabilitation process.
To this aim, clinical scales (ie, the timed up and go [TUG] test, the Tinetti Scale, the Falls Efficacy Scale–International, and the Berg Balance Scale) as well as innovative technologies, including wearable sensors and nonwearable devices, are used. Specifically, wearable sensors are growing in popularity in both clinical and research contexts due to their suitable features []: because of their small size, affordability, and user-friendly nature, wearable sensors represent an optimal solution for health monitoring [,]. Unlike traditional laboratory-based monitoring systems, wearable sensors can facilitate the continuous monitoring of motor activity by capturing physiological data during everyday routines []. In addition, fall risk assessments with laboratory-based systems are generally performed in supervised conditions, in which the behavior adopted by participants may not be representative of the one adopted in everyday life—during the experimental tasks, the participants might be attempting their “best effort” []. Generally, falls occur in unpredictable situations during everyday activities []. In this context, wearable sensors enable unsupervised fall risk assessment by providing continuous monitoring during daily functional tasks, thereby offering a reflection of the individual’s real-world fall risk [,,].
Thus, interest in wearable sensors has been increasing with regard to monitoring fall risk among older adults []. Among the prevalent wearable technologies used for health monitoring are inertial measurement units (IMUs), which gather data from accelerometers and gyroscopes. IMUs can be strategically positioned on the body to capture motion data for subsequent analysis, integration, and interpretation []. Gait characteristics that can be analyzed include stride length, stance-to-swing phase ratio, and various other spatiotemporal gait parameters [,,]. In addition, data from inertial sensors collected during walking can be used to investigate upper body dynamics through nonlinear analysis techniques, such as recurrence quantification analysis []. Some researchers have used inertial sensor data to detect balance alterations by analyzing sway speed in the anterior-posterior and medial-lateral directions of the body’s center of mass projection path in patients with AD [].
Other wearable sensors include insole-based devices, which have been developed for fall risk assessment and detection. These devices are embedded in the shoe sole to capture data on plantar pressure distribution []. The features extracted from these devices are used to objectively quantify the risk of falling in individuals with neurological disorders. However, the selection of the most reliable biomechanical gait parameters related to fall risk remains an open question []. In addition, the information acquired from wearable sensors, along with data processing, data fusion, and analysis techniques such as machine learning (ML) models or manual data analysis, is used to extract meaningful insights from the investigated parameters [].
To this aim, some studies have investigated the role of deep learning (DL) in the context of neurorehabilitation. The DL-based approach can be used to extract data on stride-specific gait parameters from IMUs []. This approach could be useful in the field of telemedicine as a potential in-home gait monitoring tool, given that alterations in gait function can serve as a biomarker for predicting fall risk.
Objectives
In this context, our first objective was to systematically review the literature on the most reliable biomechanical gait parameters, as detected by wearable sensors, for evaluating fall risk in individuals with neurological disorders. Therefore, we selected studies that involved patients with PD, MS, AD, or stroke, as these conditions collectively represent a significant proportion of neurological disorders worldwide and are associated with substantial gait impairment and a high risk of falls. Our second objective was to investigate existing literature on wearable sensor technology, including best practices for device placement as well as data processing and analysis.
Methods
Overview
We conducted a comprehensive systematic review to explore the existing evidence on fall risk assessment in patients with neurological disorders. We summarized the results of all published studies in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines []. The PRISMA checklist is available in . The protocol has been registered with PROSPERO (CRD42023463944).
Population, Exposure, Comparator, Outcomes Question
We used the population, exposure, comparator, outcomes model to define the search strategy [] (). The population, exposure, comparator, outcomes framework was applied to address the following research question: “what are the most reliable biomechanical gait parameters detected with wearable sensors to assess fall risk in neurological disorders?”
| PECO elements | Definition | Search terms |
| Population | Patients with neurological disorders, including cerebrovascular diseases, Parkinson disease, Alzheimer disease, and multiple sclerosis | “stroke” OR “Parkinson’s disease” OR “multiple sclerosis” OR “Alzheimer” |
| Exposure | Fall risk assessment using wearable sensors or gait analysis using wearable sensors | “wearable” |
| Comparator | Studies including a comparison with healthy controls | —a |
| Outcomes | Biomechanical gait parameters related to fall risk | “fall” |
aNot applicable.
Search Strategy and Eligibility Criteria
We conducted a systematic search for all peer-reviewed articles published up to April 18, 2025, using PubMed, Web of Science, Embase, and IEEE Xplore, which are the most used databases in the fields of health and bioengineering. The full search queries are provided in . We included studies involving adults (aged ≥18 y) with stroke, PD, MS, or AD. Specifically, the inclusion criteria were as follows: (1) adult patients with cerebrovascular impairments, PD, MS, or AD; (2) fall risk assessment using wearable sensors; (3) articles written in English; and (4) published in a peer-reviewed journal. We excluded articles describing theoretical models, methodological approaches, algorithms, and basic technical descriptions. We also excluded animal studies, conference proceedings and reviews, studies involving children, and case reports. The list of articles was refined for relevance, revised, and summarized, with the key topics identified from the summaries based on the inclusion and exclusion criteria. Considering the limited literature available, we included the following study designs in the qualitative synthesis: (1) randomized controlled trials, (2) observational studies, (3) cross-sectional studies, (4) case-control studies, and (5) cohort studies. All search results were imported into Rayyan (Rayyan Systems Inc) [], a web application designed to facilitate the systematic review process, and screened by 2 blinded reviewers (AI and MB). Each reviewer independently screened the articles to ensure consistent application of the inclusion and exclusion criteria. After screening titles and abstracts, blinding was removed. In cases of disagreement, the 2 reviewers discussed the inclusion or exclusion of the undecided articles to reach consensus.
Data Extraction and Analysis
After full-text selection, data from the included studies were extracted and organized in a spreadsheet. Information was summarized using the following fields: assigned ID number, study title, year of publication or presentation and first author, study aims and design, study duration, recruitment method and setting, inclusion and exclusion criteria, use of a control group, use of wearable sensors, informed consent, conflicts of interest and funding, type of intervention or evaluation and control, number of participants, baseline characteristics, intervention setting, types of biomechanical parameters related to fall risk, results, and key conclusions. Data extraction was performed independently and in a blinded manner by 2 reviewers. In cases of disagreement, a third reviewer was consulted to resolve discrepancies.
Risk of Bias
The risk of bias in the included studies was assessed using the National Heart, Lung, and Blood Institute Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies []. This tool comprises 14 questions, with each item rated as “yes,” “no,” “cannot determine,” “not reported,” or “not applicable.” On the basis of the responses, the overall quality of each study was categorized as good, fair, or poor. The risk of bias was assessed independently and in a blinded manner by 2 reviewers. In cases of disagreement, a third reviewer was consulted to resolve discrepancies.
Results
Overview
A total of 134 articles were identified through database search (PubMed: n=25, 18.7%; Web of Science: n=64, 47.8%; Embase: n=26, 19.4; and IEEE Xplore: n=19, 14.2%). After removing duplicates (57/134, 42.5%), we screened the remaining articles (77/134, 57.5%). Of these 77 articles, 69 (90%) met the inclusion criteria, and 8 (10%) were excluded. After full-text analysis, of the 69 articles, 50 (72%) were excluded, and 19 (28%) studies involving 5859 participants were included in the review synthesis (). The included studies were published between 2016 and 2025.

Quality of the Studies and Risk-of-Bias Assessment
The risk of bias in the included studies was assessed using the National Heart, Lung, and Blood Institute Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies, which comprises 14 questions ()

All included studies were rated by the reviewers as having overall good quality (), and there was homogeneity in the methodologies and procedures used to assess fall risk in neurological disorders. However, concerns were identified in some domains of the quality assessment tool, specifically items 3, 5, 12, and 13; for example, participation rates of eligible individuals were documented in only 5% (1/19) of the studies [], a sample-size justification or power analysis was provided only in the study by Sturchio et al [], repeat assessment of the exposure was described in only 21% (4/19) of the studies [,,,], and 79% (15/19) of the studies relied on a single measurement or used a cross-sectional design. Moreover, procedures for blinding outcome assessors to exposure status were not reported, and information sufficient to determine loss to follow-up was not provided in the prospective cohort studies. However, these reporting limitations did not affect the overall quality classification assigned to each study.
Study Population
The included studies involved 2630 patients with neurological disorders, including 226 (8.59%) with MS (n=7, 37% studies), 2305 (87.64%) with PD (n=10, 53% studies), 51 (1.94%) with stroke (n=3, 16% studies), and 48 (1.83%) with AD or cognitive impairment (n=1, 5% study). An additional 3229 participants were healthy controls or older adults. Regarding disease severity, the studies conducted in patients with MS had a mean Expanded Disability Status Scale score of 3.4; and in patients with PD, the mean score on the Unified Parkinson’s Disease Rating Scale, part III (motor examination), was 26.6, while the mean Hoehn and Yahr stage was 2.58 (based on the studies that reported these metrics). Regarding patients with stroke, 2 (11%) of the 19 studies [,] included participants who had experienced a cerebrovascular accident at least 5 years earlier, while 1 (5%) included patients who had experienced a stroke at least 6 months before the day of the experiment [] ().
| Neurological disorders and studies | Study design | Sample size, n (etiology) | Demographics | Study aim | Major findings | |
| MSa | ||||||
| Hildebrand et al [], 2021 | Prospective cohort study | 25 (MS) | Female: 17; male: 8; EDSSb: median 6.0 (IQR 5.5-6.0); RRc: 11; SPd: 8; PPe: 6 | The study compared the sensitivity and false discovery rates of 3 fall detection methods: prospective paper fall calendars, real-time self-reporting, and automated detection using a body-worn device | Fall calendars likely underestimate fall frequency by approximately 40%, whereas the automated detector misses very few falls but likely overestimates the number of falls by approximately 1 per day | |
| Tulipani et al [], 2022 | Cross-sectional methodological case-control study | 37 (MS—nonfallers: 17; fallers: 21) | EDSS—nonfallers: mean 2.0 (SD 0.8); fallers: mean 3.3 (SD 1.4) | Participants completed the 30CSTf in both supervised (laboratory) and unsupervised (home) settings while wearing a thigh-mounted triaxial accelerometer; in the unsupervised setting, they also performed 30CSTs every 2 h and rated their balance confidence and fatigue over 48 h | Short periods of instrumented, unsupervised monitoring, in addition to regular clinical assessments, could enhance the accuracy of fall risk prediction | |
| Tulipani et al [], 2020 | Cross-sectional methodological case-control study | 38 (MS—nonfallers: 17; fallers: 21) | EDSS—nonfallers: mean 2.3 (SD 1.2); fallers: mean 3.4 (SD 1.2) | Participants completed self-report measures and performed the 30CST, with triaxial acceleration data collected from sensors on the thigh and chest; the study assessed the relationship between accelerometer metrics and clinical measures and developed a logistic regression model to classify fall status | Accelerometer-derived metrics were linked to clinically relevant measures of disease severity, fatigue, and balance confidence during balance-challenging tasks, suggesting that inertial sensors could improve functional assessments and fall risk identification, with their simplicity aiding community-based monitoring | |
| Meyer et al [], 2022 | Cross-sectional study with follow-up | 38 (MS—nonfallers: 17; fallers: 21) | Male: 12; female: 26; EDSS—nonfallers: mean 2.3 (SD 1.0); fallers: mean 3.3 (SD 1.4) | Participants were categorized as fallers or nonfallers based on self-reported falls, underwent clinical assessments, completed balance and fatigue surveys, performed laboratory-based mobility tests while wearing MC10 BioStamp sensors to collect accelerometer and EMGg data, and continued to wear the sensors at home for 48 h to monitor acceleration | Deep learning models performed better than feature-based models when analyzing home data, particularly when using all walking bouts for deep learning and shorter bouts for feature-based models in individual bout evaluations; longer free-living walking bouts showed more pronounced differences between fallers and nonfallers compared to shorter bouts, and aggregating data from all free-living walking bouts resulted in the highest accuracy for fall risk classification | |
| Meyer et al [], 2021 | Cross-sectional methodological case-control study | 37 (MS—nonfallers: 19; fallers: 18) | Male: 11; female: 26; EDSS—mean 2.99 (SD 1.47) | The study distinguished fallers from nonfallers based on a 1-min walking task; participants were evaluated using wearable sensors to collect accelerometer data | The BiLSTMh deep learning model achieved the highest performance with an AUCi of 0.88, suggesting that deep learning using gait acceleration data is effective for classifying fall status | |
| Kushner et al [], 2023 | Prospective cohort study | 25 (MS) | Male: 8; female: 17; EDSS: median 6.0 (IQR 5.5-6.0); RR: 11; SP: 8; PP: 6 | Participants were monitored over 8 wk using an inertial sensor equipped with a triaxial accelerometer and time-of-flight radio transmitter, communicating with beacons placed throughout the home, to assess associations between home locations and movement behaviors before falls compared to periods without falls | Movement metrics obtained from wearable sensors and smart-home tracking systems were correlated with fall risk, with increased pauses during walking and more complex, longer movement paths indicating higher fall risk | |
| Arpan et al [], 2022 | Prospective cohort study | 26 (MS—nonfallers: 13; fallers: 13) | EDSS—nonfallers: mean 4.3 (SD 0.23); fallers: mean 4.2 (SD 0.18) | The study computed the AUC values for each gait measure that differentiated fallers from nonfallers and then ranked values from highest to lowest to assess their effectiveness in predicting falls based on instrumented measures of mobility using a univariate model | Objective monitoring of gait and turning in daily life identified those at risk of future falls, with the pitch at toe-off identified as the most significant predictor, suggesting potential benefits from interventions targeting plantarflexion muscle strength, range of motion, and proprioceptive input | |
| PDj | ||||||
| Greene et al [], 2021 | Cross-sectional study with follow-up | 1057 (PD [more impaired]: 15; PD [less impaired]: 26; controls: 1015) | Participants with PD (more impaired)—male: 10; female: 5; participants with PD (less impaired)—male: 17; female: 9; UPDRS-IIIk—participants with PD (more impaired): mean 15.1 (SD 9.6); participants with PD (less impaired): mean 22.56 (SD 10.25); healthy controls—male: 344; female: 671 | The study analyzed data using 2 statistical approaches to predict fall counts: a previously reported fall risk assessment algorithm as well as elastic net and ensemble regression models | The study found a robust correlation between fall counts and a previously established inertial sensor–based fall risk estimate, as well as significant associations between fall counts and various individual gait and mobility parameters, suggesting that falls predicted from inertial sensor data during a basic walking task could serve as a promising digital biomarker for PD warranting further validation in clinical settings | |
| Pallavi et al [], 2023 | Cross-sectional study | 28 (PD: 14; healthy controls: 14) | Participants with PD—male: 11; female: 3; UPDRS: mean 35.5 (SD 19.4); H&Yl: mean 2.2 (SD 0.7); healthy controls—male: 11; female: 3 | Participants were asked to walk overground on a 10-m pathway, both without turns and with 180° turns, under varying task conditions of increasing complexity (single-, dual-, and multiple-task conditions) | The knee flexion and gait-related indices strongly aligned with clinical measures of fear of falling, especially in the group with PD, providing valuable predictive information for clinicians | |
| Silva de Lima et al [], 2020 | Prospective cohort study | 4126 (PD: 2063; healthy controls: 2063) | Participants with PD—male: 996; female: 1067; healthy controls—male: 992; female: 1071 | The study used a PERSm, which consisted of a device—worn as a necklace—with multiple embedded sensors for automatic fall detection and manual fall reporting; fall events were reported either by a button push or automatically detected by the fall detector | Wearable sensors were used to collect fall data, revealing that PD nearly doubles fall incidence in everyday life, underscoring PD as a significant fall risk; in addition, monitoring fall events in >4000 participants using a wearable sensor connected to a PERS suggests the potential of body-worn sensors for continuous home monitoring | |
| Sturchio et al [], 2021 | Prospective cohort study | 26 (PD and OHn) | Male: 19; female: 7; UPDRS-III: mean 40.1 (SD 13.4) | The study estimated the association of PD and OH with fall risk association with fall risk, capturing fall frequency through a diary over 6 mo | Kinematic measures, rather than clinical assessments, predicted falls in PD with OH, suggesting that orthostatic mean arterial pressure of ≤75 mm Hg may indicate a hemodynamic threshold associated with increased fall risk, advocating for proactive corrective interventions | |
| Nouriani et al [], 2023 | Cross-sectional algorithm validation with prospective cohort | 21 (PD: 11; healthy controls: 10) | UPDRS pull test: mean 0.56 (SD 0.96) | The study validated the activity recognition algorithm through video footage of participants with PD wearing sensors at home | The findings suggest that incorporating near-fall detection into home monitoring data significantly enhances the performance of fall prediction algorithm | |
| Ullrich et al [], 2023 | Prospective cohort study | 35 (PD—nonfallers: 25; fallers: 10) | Male: 26; female: 9; UPDRS—nonfallers: mean 12.9 (SD 6.2); fallers: mean 21.7 (SD 9.1); H&Y—nonfallers: mean 2.3 (SD 0.5); fallers: mean 2.9 (SD 0.5) | The study compared various data aggregation methods and machine learning models for predicting fall risk using gait parameters obtained from continuous real-world recordings and unsupervised gait tests | The findings indicate that combining 2 wk of real-world gait data provides the most accurate prediction of fall risk, surpassing predictions based solely on unsupervised gait tests (balanced accuracy of 68%), thereby advancing understanding in fall risk prediction | |
| Ma et al [], 2022 | Prospective cohort study | 51 (PD) | Male: 33; female: 18; UPDRS-III: mean 33.6 (SD 13.5); H&Y: mean 2.4 (SD 0.8) | Using wearable sensors, the study objectively evaluated gait characteristics in participants with PD who experienced falls; it also explored the relationship between spatiotemporal gait parameters, gait variability, and falls over a 6-mo follow-up period | Increased gait variability is a notable characteristic among individuals with PD who experience falls and proves more sensitive in identifying those at elevated risk of falls than spatiotemporal parameters | |
| Song et al [], 2025 | Cross-sectional case-control study | 111 (PD: 29; healthy controls: 18 [dataset III]; PD: 35; healthy controls: 29 [dataset IV]) | Participants with PD—male: 20; female: 9; age: mean 71.1 (SD 8.1) y; healthy controls—male: 10; female 8; age: mean 71.6 (SD 6.7) y (dataset III); participants with PD—male: 22; female: 13; age: mean 61.6 (SD 8.9) y; healthy controls—male: 18; female 11; age: mean 57.9 (SD 7.0) y (dataset IV) | The study identified an abnormal gait pattern termed recessive weak foot, characterized by a discontinuous high-risk gait on the weak foot side, observed through weak foot feature space; to address this, the authors proposed a trainable threshold method to discriminate individuals with this pattern, thereby enhancing the model’s generalization performance; the authors conducted feasibility and ablation studies on 2 self-established datasets and tested the compatibility on 2 published gait-related datasets of participants with PD | Guided by a customized index and the optimized adaptive thresholds, the method used by the authors effectively screened out individuals with recessive weak foot; specifically, after fine adaptation, the individual-specific models could achieve accuracies of 87.5% and 73.6% on an enhanced dataset; compared to the baseline, the proposed 2-stage model demonstrated improved performance, with an accuracy of 85.4% and sensitivity of 87.5%; in the dataset of participants with PD, the authors’ method mitigated potential overfitting from low feature dimensions, increasing accuracy by 4.7% | |
| ADo | ||||||
| Huang et al [], 2022 | Cross-sectional study | 103 (older adults with CIp, including those with aMCIq and mild AD: 48; cognitively healthy older adults: 55) | Participants with CI—male: 21; female: 27; age: mean 65.7 (SD 5.2) y; cognitively healthy participants—male: 15; female: 40; age: mean 67.1 (SD 4.1) y | The study primarily examined the association between memory deficit and increased fall risk; it also explored the underlying neuroanatomical linkage of this association in older adults with aMCI and mild AD | The authors’ findings suggested that memory deficit was associated with increased fall risk in older adults with aMCI and mild AD; the association might be mediated by the atrophy of the medial temporal, frontal, and parietal lobes; in addition, increased fall risk, tested by timed up and go time, heel stride angles, and stride speed, might be objective and convenient kinematics markers for dynamic monitoring of both memory function and fall risk | |
| Stroke | ||||||
| Taylor-Piliae et al [], 2016 | Cross-sectional feasibility study | 20 (stroke: 10 [ischemic stroke: 6; hemorrhagic stroke: 4]; healthy controls: 10) | Participants with stroke: female: 7; male: 3; healthy controls: female: 9; male: 1; poststroke duration: mean 42 (SD 25) mo | The study assessed the feasibility of using a kinematic motion sensor (PAMSys) to monitor fall risk and gait in community-dwelling survivors of stroke by evaluating the acceptability of wearing the sensor for 48 h, identifying fall risk indicators and gait parameters, and comparing these metrics with data from age-matched nonfrail controls | Survivors of stroke found 48 h of continuous PAMSys monitoring highly acceptable, suggesting that in-home wearable technology could be valuable for monitoring fall risk and gait, potentially aiding in recovery efforts | |
| Botonis et al [], 2022 | Cross-sectional study | 35 (stroke: 20; healthy controls: 15) | Participants with stroke—male: 10; female: 10; poststroke duration: mean 7.47 (SD 4.58) y; healthy controls—male: 8; female: 7 | The study investigated whether population-specific training data and modeling parameters were necessary to predetect falls in individuals with chronic stroke | The findings underscore the significance of population-specific sensitivity, use of nonfall data, and optimal lead time for machine learning–based preimpact fall detection tailored for individuals with stroke, suggesting a need for the inclusion of individuals with neurological impairments in model development for effective fall detection in other populations considered to be at high risk | |
| Abdollahi et al [], 2024 | Prospective cohort study | 21 (stroke) | Male: 11; female: 10; age: mean 66 (SD 10) y | The study aimed to develop machine learning models using inertial sensors to objectively classify fall risk in survivors of stroke | The random forest model achieved 91% accuracy using dual-task balance sway and timed up and go walk time features; single thorax sensor models performed similarly to multisensor models; balance and timed up and go best predicted fall risk | |
aMS: multiple sclerosis.
bEDSS: Expanded Disability Status Scale.
cRR: relapsing-remitting.
dSP: secondary progressive.
ePP: primary progressive.
f30CST: 30-second chair stand test.
gEMG: electromyography.
hBiLSTM: bidirectional long short-term memory.
iAUC: area under the receiver operating characteristic curve.
jPD: Parkinson disease.
kUPDRS-III: Unified Parkinson’s Disease Rating Scale, part III (motor examination).
lH&Y: Hoehn and Yahr.
mPERS: personal emergency response system.
nOH: orthostatic hypotension.
oAD: Alzheimer disease.
pCI: cognitive impairment.
qaMCI: amnestic mild cognitive impairment.
Classification of the Results
We classified our results according to the type of motor task (supervised vs unsupervised), the biomechanical parameters extracted, and the technological equipment used as well as the artificial intelligence (AI) approach applied in the included studies.
Motor Task for Fall Risk Detection
Of the 19 included studies, 12 (63%) assessed fall risk through supervised motor tasks, administered in clinical or laboratory settings, while the remaining 7 (37%) evaluated fall risk through unsupervised gait tasks recorded in real-world environments.
Supervised Motor Tasks
Generally, supervised motor tasks consisted of instrumented versions of the TUG test [,,,,], the 30-second chair stand test (30CST) [,,], and simulated daily activities [,]. However, Tulipani et al [] compared supervised 30CST with unsupervised 30CST in a home-based setting. The authors reported a substantial statistical difference between the 2 types of motor tasks, suggesting that the laboratory setting could influence the fall risk rate. Some of the studies (5/19, 26%) [,,,,] administered a specific assessment protocol to quantify the risk of falls in patients with neurological disorders, while the studies by Pallavi et al [] and Greene et al [] quantified fall risk using solely TUG or gait tasks. Similarly, the study by Song et al [] analyzed different datasets in which the only motor task consisted of walking along a 20-meter corridor for at least 2 minutes under observation. Interestingly, Sturchio et al [] conducted an instrumented assessment of activities of daily living (ADLs) in a standardized home-like environment, in addition to clinical tests (eg, the TUG test, the 2-minute walk test, and other standard measures; ). The TUG test was also used to assess gait function in patients with AD []. Similarly, Meyer et al [], acquired sensor data from simulated daily activities in addition to several standard functional assessments. In the study by Abdollahi et al [], patients with stroke completed clinical tasks, including balance tests (eyes open and closed), the TUG test, the 10-meter walk test, and the sit-to-stand test. Each was also performed as a motor-cognitive dual task, involving backward counting during movement. Finally, Botonis et al [] evaluated fall risk in patients with stroke through balance response reactivity in a laboratory setting.
Unsupervised Motor Tasks
Of the 19 included studies, 7 (37%) [,-,,,] assessed fall risk using unsupervised recordings in a real-world environment. In general, these assessments were conducted during ADLs [,,] or gait tasks [,,]. Notably, Silva de Lima et al [] detected fall events automatically using a wearable sensor, without monitoring ADLs or gait.
Fall Risk Biomechanical Parameters
We analyzed features extracted from wearable sensors related to the quantification of supervised or unsupervised motor tasks in patients with MS, PD, or stroke. Several of the studies (10/19, 53%) [,,-,,-,] extracted specific gait parameters from wearable sensors. These parameters consisted mainly of spatiotemporal parameters of gait [,,], anterior-posterior and medial-lateral acceleration [], lower limb joint angles, and cadence []. In particular, Arpan et al [] extracted specific gait parameters to differentiate fallers from nonfallers. These biomechanical parameters reflected gait quality (eg, gait speed, stride length, cadence, and swing) as well as turning function []. In addition, Song et al [] extracted 44 gait features mainly from plantar pressure data, focusing on the weaker foot. These features were used to identify a novel gait dysfunction, termed recessive weak foot, which was characterized by discontinuous high-risk gait patterns. Furthermore, Abdollahi et al [] and Huang et al [] extracted spatiotemporal gait parameters derived from the clinical tests (the TUG test and the 10-meter walk test). Only 2 (11%) of the 19 studies [,] extracted balance features in addition to gait parameters. In particular, Sturchio et al [] evaluated oscillations in the center of pressure and center of mass, the frequency of oscillations, and jerkiness in patients with PD. The authors also evaluated upper limb range of motion during motor tasks. Similarly, Arpan et al [] evaluated upper body kinematics alongside gait quality through spatiotemporal parameters and additionally calculated specific parameters during gait turning. Gait turning and postural transfers were also analyzed by Greene et al [], while Tulipani et al [,] focused on specific biomechanical parameters during the 30CST ().
As shown in , the majority of the included studies (18/19, 95%) analyzed gait parameters, such as spatiotemporal features. These features were mostly considered in patients with PD or MS. In addition, some of the studies (7/19, 37%) extracted biomechanical features from clinical tests, such as 30CST and TUG (eg, TUG time, turning activity, 30CST average time, and repetitions). Concerning patients with stroke, it was difficult to define a common pattern of extracted biomechanical features because only 3 studies were available; however, both considered fall characteristics and parameters related to postural changes, similar to those examined in studies involving patients with PD or MS [,].
| Neurological disorders and studies | Motor task | Parameters analyzed | |
| Multiple sclerosis | |||
| Hildebrand et al [], 2021 | Unsupervised tasks during daily life activities |
| |
| Tulipani et al [], 2022 | 30CSTb—the participant was encouraged to complete as many full stands as possible within 30 s |
| |
| Tulipani et al [], 2020 | Participants performed a series of functional assessments, including 1 trial each of the 30CST, T25Wc, and TUG, as well as a 30-s static standing trial with instructions to maintain a tall posture with their feet facing forward, wearing inertial sensors on the anterior right thigh and chest |
| |
| Meyer et al [], 2022 | Supervised tasks completed in the following order: TUG; T25W; 30CST; lying-to-standing transition; 3 separate 2-minute standing tests (tandem standing, feet shoulder width apart with eyes open, and feet shoulder width apart with eyes closed); 1-min hallway walk at a self-selected pace, including 1 turn; 30-s normal standing; 30-s upright sitting; 30-s slouch sitting; and 30 s each lying on the back, left side, right side, and prone |
| |
| Meyer et al [], 2021 | Data from these sensors were recorded during a variety of simulated daily activities and several standard functional assessments |
| |
| Kushner et al [], 2023 | Unsupervised tasks during daily life activities (eg, gait quality and turning) |
| |
| Arpan et al [], 2022 | Unsupervised tasks during daily life activities (eg, gait quality and turning) |
| |
| Parkinson disease | |||
| Greene et al [], 2021 | Supervised TUG test, instrumented with inertial sensors |
| |
| Pallavi et al [], 2023 | Gait tasks: single, dual, and multiple |
| |
| Silva de Lima et al [], 2020 | Unsupervised; fall events were collected either automatically using the wearable fall detector or were registered by a button push on the same device |
| |
| Sturchio et al [], 2021 | Participants performed the following tasks: lying-to-standing test (standing up without assistance after 10 min of supine resting and keeping the upright position for 5 min), tests of gait and postural stability (TUG, 2MWTd, and sway [eyes opened and eyes closed]), and ADLse conducted in a standardized home-like environment |
| |
| Nouriani et al [], 2023 | Unsupervised tasks during daily life activities |
| |
| Ullrich et al [], 2023 | Unconstrained real-world gait analysis and unsupervised gait tasks |
| |
| Ma et al [], 2022 | Participants were required to complete a 7-meter TUG test twice (stand up from an armless chair, walk at own comfortable pace for 7 meters, turn 180°, then walk back and sit down) |
| |
| Song et al [], 2025 | Participants were asked to walk for at least 2 min consecutively at their normal gait and speed along a 20-meter-long corridor |
| |
| Alzheimer disease | |||
| Huang et al [], 2022 | Supervised TUG test |
| |
| Stroke | |||
| Taylor-Piliae et al [], 2016 | Unsupervised tasks during daily life activities |
| |
| Botonis et al [], 2022 | Participants were instructed to respond to loss of balance using any natural technique, such as using an arm to catch themselves or taking multiple steps, to encourage realistic behavior |
| |
| Abdollahi et al [], 2024 | Balance test (stand as still as possible for 30 s with eyes open or closed on a firm surface), TUG, 10MWTj, STSk, and motor-cognitive dual tasks (repetition of the aforementioned tasks while counting backward from 200 by 10s) |
| |
aTUG: timed up and go.
b30CST: 30-second chair stand test.
cT25W: timed 25-foot walk.
d2MWT: 2-minute walk test.
eADL: activity of daily living.
fCoP: center of pressure.
gCoM: center of mass.
hCF: centroidal frequency.
iIMU: inertial measurement unit.
j10MWT: 10-meter walk test.
kSTS: sit-to-stand.
Technological Equipment, Data Processing, and Analysis Approaches
This subsection describes the technological equipment and data processing methods used across the included studies. Of the 19 studies, 7 (37%) [,,,,,,] focused on fall risk assessment in patients with MS using wearable sensors. Of these 7 studies, 4 (57%) used the MC10 BioStamp system, which integrates triaxial accelerometers, gyroscopes, and electromyography (EMG) sensors to capture a wide range of motion data [,,,]. Tulipani et al [] examined accelerometer metrics from thigh and chest sensors and applied logistic regression models to distinguish fallers from nonfallers, achieving an area under the receiver operating characteristic curve (AUC) of 0.78 and an accuracy of 74%. In the study by Tulipani et al [], a single sensor placed on the thigh was used to record data during tests, and the authors used receiver operating characteristic analysis to optimize classification thresholds. This improved predictive performance in unsupervised settings, with an AUC of 0.79 and an accuracy of 78.4%.
Meyer et al [] used BioStamp in conjunction with APDM Opal wearable sensors. Data were acquired from triaxial accelerometer sensors secured to the sternum (below the clavicle) and to the anterior portion of the right thigh. In addition, the authors recorded data from accelerometers and angular rate gyroscopes secured to the lower sternum, lower back (at the belt line), and anterior right and left shanks. The authors demonstrated that a bidirectional long short-term memory (LSTM) deep neural network could identify patients with MS who had recently fallen, achieving an AUC of 0.88 and an accuracy of 86%, based on data collected from 2 wearable sensors during a 1-minute task [].
In the study by Meyer et al [], accelerometer and EMG data were collected from the right and left tibialis anterior, while accelerometer and angular rate gyroscope data were collected from the chest and lower back as well as bilaterally from the anterior thighs, proximal lateral shank, and dorsal aspect of the feet. EMG data were collected to allow the investigation of foot drop. The models tested in this study showed that short walking bouts were the best predictor of fall risk in free-living conditions (AUC=0.63). By contrast, medium and long walking bouts had lower predictive performance, with AUCs of 0.52 and 0.54, respectively. DL models, especially LSTM models that used up to 22 strides, outperformed traditional feature-based models, with the LSTM model achieving an AUC of 0.76, showing its robustness in discerning fall risk from complex gait patterns. Hildebrand et al [] and Kushner et al [] used an automated fall detection system that integrated a body-worn IMU (placed on the waist) with a button for self-reporting falls and an ML algorithm trained to evaluate falls in real-world environments in patients with MS []. Specifically, the algorithm used an autoencoder that identifies individuals at increased risk of falling using reconstruction errors in accelerometer signals, followed by a hyper-ensemble of balanced random forests trained on acceleration and movement features. Hildebrand et al [] compared 3 methods for detecting falls in patients with MS: traditional paper fall calendars, real-time self-reporting using a body-worn device, and automated fall detection using the same device. The results showed that paper calendars had a sensitivity of 61.4% and a false discovery rate of 6.7%, indicating that they likely underestimated the number of falls. By contrast, the automated detection system had a high sensitivity of 92.1% but also a high false discovery rate of 91.9%, indicating that it likely overestimated fall occurrences. The study highlighted the challenges of balancing high sensitivity with minimizing false positives in real-world applications. Kushner et al [] focused on extracting movement complexity metrics from wearable sensors. The study used a k-nearest neighbors ML algorithm for room detection and applied complex statistical methods to estimate movement-based fall risk. The findings indicated that movement complexity, measured by the entropy of room transitions, was notably higher in the periods leading up to falls, suggesting that increased movement complexity is a strong predictor of fall risk. Arpan et al [] used a different set of wearable technologies to passively monitor gait and turning behaviors in daily life to predict falls in patients with MS. This setup involved triaxial accelerometers, gyroscopes, and magnetometers (Opal sensors) placed on the top of the foot and integrated into instrumented socks, along with a sensor worn on the lower lumbar region. The data collected from these sensors were processed using an unscented Kalman filter technique to fuse accelerometer and gyroscope data and identify walking bouts and turning behaviors. The raw data were further processed using commercial gait analysis algorithms in Mobility Lab to derive spatiotemporal measures of gait and turning. The study found that reduced plantarflexion during toe-off, reflected by the pitch angle of the foot during the push-off phase of walking, was the most significant predictor of falls, achieving an AUC of 0.86, indicating strong predictive power [].
Of the 19 studies, 8 (42%) [,,,,-,] focused on integrating advanced wearable sensors and complex data analysis methods to monitor and predict fall risks in patients with PD. Silva de Lima et al [] used a wearable sensor worn as a necklace (Philips Lifeline FD100) to monitor falls in patients with PD in their home environments. Although the study did not predict falls, it revealed a significantly higher incidence of falls in patients with PD compared to controls, demonstrating the pronounced fall risk in this population []. Song et al [] analyzed PD gait data from intelligent footwear with 16 plantar pressure sensors embedded in each insole. The authors proposed a 2-stage model that first identifies individuals with PD with irregular gait patterns, referred to as recessive weak foot, using an adaptive threshold based on the distribution difference index. In the second stage, separate personalized ML models (such as support vector machines, logistic regression, and decision trees) are trained for individuals with recessive and dominant weak foot patterns, enabling a more accurate and individualized assessment of fall risk.
Of the 19 studies, 3 (16%) used compact gait analysis systems to collect comprehensive kinematic data. Ma et al [] and Sturchio et al [] used the Mobility Lab system, which includes 6 wearable sensors (accelerometers, gyroscopes, and magnetometers) placed on the feet, wrists, sternum, and lumbar region. Ullrich et al [] used the Mobile GaitLab system, with sensors positioned on the instep of both the left and right shoes. Similarly, Huang et al [] used the JiBuEn gait analysis system, which consists of wearable sensors embedded in specially designed shoes. Ma et al [] focused on gait variability as a predictive marker for falls in patients with PD, capturing metrics such as stride length, gait cycle time, and range of motion of the trunk in the sagittal plane. The authors found that variability in the trunk range of motion during walking was a significant independent risk factor for falls in patients with PD, achieving a prediction accuracy with an AUC of 0.75. The overall logistic regression model, which included multiple gait parameters, predicted falls with a higher accuracy with an AUC of 0.84 []. Sturchio et al [] focused on fall risk in patients with PD with orthostatic hypotension and found that waist sway, jerkiness, and postural sway were more predictive of falls than traditional clinical assessments, achieving an AUC of ≥0.81 for predicting fall risk. Ullrich et al [] focused on fall risk prediction in patients with PD by analyzing real-world gait data. The study used ML algorithms, notably random forest classifiers, to analyze the aggregated gait data for fall risk prediction. The highest predictive performance was achieved using participant-wise aggregated data, resulting in a balanced accuracy of 74%, with a sensitivity of 60% and a specificity of 88% [].
Greene et al [] explored the utility of wearable sensors during the TUG test to develop a digital biomarker for predicting fall counts. The study applied 2 statistical approaches to predict fall counts: a fall risk assessment algorithm reported in previous studies by the same team [,] and an ensemble model combining elastic net and regression models using Poisson regression. The research findings suggest a strong association between the fall counts predicted from the inertial sensor data and actual falls []. Nouriani et al [] validated an activity recognition algorithm and developed novel behavioral biomarkers to assess fall risk in patients with movement disorders, focusing on PD and normal pressure hydrocephalus. The study used 5 IMUs strategically placed on the chest, upper legs, and lower legs of participants, capable of measuring acceleration, angular rates, and orientation. The core of the study’s methodology involved a DL-based activity recognition architecture using a convolutional neural network combined with LSTM cells. This advanced ML approach allowed for the accurate detection of complex activities and postural transitions that are critical indicators of fall risk. The algorithm’s performance was validated against video [], achieving high sensitivity (>95%) in detecting activities and an 80% sensitivity for near falls.
Finally, Pallavi et al [] used a novel wearable sensor (SmartWalk) to evaluate knee flexion and gait indices during walking tasks under different cognitive load conditions. The study found that variability in knee flexion increased significantly under dual-task conditions, which were closely associated with a fear of falling. The findings indicate significant increases in the variability of knee flexion during walking tasks, particularly under dual- and multiple-task conditions, which pose higher cognitive demands and thus exacerbate gait and postural disturbances in patients with PD. A strong relationship between measured indices and clinical assessments of fear of falling was found using statistical analyses, including k-means clustering and correlation assessments [].
Of the 19 studies, 3 (16%) [,,] focused on fall assessment in survivors of stroke. Botonis et al [] investigated the efficacy of wearable airbag technology paired with ML models to prevent falls. The device included 3 IMU sensors (on the hips and lower back) and used adaptive boosting classifiers to differentiate fallers from nonfallers. Two models were developed: one trained on survivors of stroke and the other on control data. The stroke-specific model significantly outperformed the control model in detecting true falls, especially in classifying complex fall movements in anterior-posterior directions. In addition, training the model with daily activity data enhanced its accuracy in fall classification []. Taylor-Piliae et al [] explored the feasibility of using a wearable sensor technology (PAMSys) for objective fall risk and gait monitoring in community-dwelling survivors of stroke. The triaxial accelerometer was worn in a midsternal pocket of a custom T-shirt, continuously recording movement data focused on postural transitions, such as the sit-to-stand test. Data on steps, speed, and movement transitions were recorded over 48 hours and compared with controls. The analysis showed that survivors of stroke exhibited worse fall risk indicators, taking longer to change posture and having more failed sit-to-stand attempts than controls []. In another study [], 8 IMUs (placed on feet, shanks, thighs, pelvis, and thorax) per participant were used. The authors analyzed the gait kinematic data extracted from IMUs with ML algorithms. In particular, they used classification algorithms, including random forest, support vector machine, and logistic regression. Among these, the random forest achieved 91% accuracy using just 2 features: thorax mediolateral acceleration during dual-task balance and TUG walk time.
The distribution of sensors reveals a concentration on the lower limbs and trunk ().

Discussion
Principal Findings
In this systematic review, we emphasize the important role of wearable technologies in performing objective and quantitative evaluations of fall risk among patients with neurological disorders. While the studies included were generally well conducted, we noted considerable variability in sensor placement, the types of wearable sensors, motor tasks, and assessment methodologies. In addition, the lack of a standardized approach to fall risk assessment using wearable sensors likely reflects the field’s ongoing technological evolution. To the best of our knowledge, this is the first systematic review analyzing the biomechanical features detected from wearable sensors for fall risk assessment in patients with PD, MS, AD, or stroke. Other studies [] have investigated the role of inertial sensor–based and insole-based wearable sensors to evaluate fall risk in older adults. In line with our results, these studies identified several biomechanical gait parameters, including spatiotemporal parameters, balance features (center of pressure trajectory), and ADLs that were registered to detect fall risk. However, in our systematic review, we found some differences in the assessment of the risk of falling related mainly to the characteristics of the neurological disorders considered. Furthermore, we noticed differences between the studies concerning technological equipment.
Moreover, another systematic review [] examined the use of wearable sensors to detect freezing of gait and falls in patients with PD. Consistent with our findings, the authors identified the most common sensor placements, such as the thigh, ankle, and lower back, which align with those reported in our review (). However, our study presents some key differences: we included a broader range of neurological disorders (eg, MS, AD, and stroke), focused specifically on fall detection and fall risk assessment, and incorporated more recent literature.
Pathological and Biomechanical Gait Characteristics Leading to Falls
Falls are very common in individuals with neurological disorders and are influenced by various aspects and features of gait. According to Zhou et al [], gait variables related to pace (eg, stride and velocity), rhythm (eg, stride duration as well as stance and swing time), variability (eg, SD of ankle dorsiflexion at heel strike), and spatial parameters (eg, stride length, plantar flexion at toe-off, and ankle dorsiflexion at heel strike) can help classify individuals with neurological disorders as fallers. However, neurological disorders are heterogeneous, and each condition is associated with specific gait features that could lead to an increased fall risk; for instance, in patients with MS, although the location, number, and size of MS lesions vary among individuals, certain common characteristics in gait deficits associated with MS have been observed. Patients with MS [] may exhibit shorter steps, reduced cadence, prolonged double support time, and increased swing phase time. Moreover, some studies have emphasized that patients with MS have reduced joint motion at the hip and ankle and increased joint motion at the knee, with a hyperextension that is more pronounced during midstance []. Falls in this patient population can occur early after disease onset; and some factors increase the risk, such as poor visual acuity, impaired postural control, and altered proprioception. However, the studies included in this systematic review analyzed only specific biomechanical metrics related to clinical tests (eg, 30CST) [,] or analyzed spatiotemporal features of gait and turning angle [,,]. According to Tulipani et al [], the 30CST could be a useful test to discriminate “fallers” and “nonfallers” in patients with MS, as it can detect balance impairments and muscle fatigue, both of which are associated with falls. Another important aspect is that remote fall risk monitoring using wearable sensors has the potential advantage of augmenting clinical visits to gain a broader perspective of patient function, symptom fluctuation, and fall risk. In patients with PD, a critical factor that is associated with falls is freezing of gait. However, it is not the only risk factor involved in falls. People with PD can experience bradykinesia, muscle weakness, and body rigidity, all of which contribute to slower gait and are closely linked to fall rates []. According to Pelicioni et al [], reduced quadriceps strength, poor balance and postural stability, and reduced mobility (as indicated by slower TUG test performance) could explain the increased prevalence of balance-related falls. These results are in line with those reported in the included studies; for example, Greene et al [] found strong associations between fall counts and several individual gait and mobility parameters, including gait variability, during the TUG test. Gait variability refers to fluctuations in gait patterns, and in patients with PD, it reflects a loss of consistency in the ability to produce a steady gait rhythm, thus presenting a likelihood of a fall. In addition, Ma et al [] found that patients with PD who experienced falls exhibited greater range of motion of the trunk in the sagittal plane than nonfallers. This aspect was identified by the authors as an independent risk factor for falls in patients with PD; and it could be used to predict falls, especially when it is combined with age, gender, and other gait parameters. From these results, it seems that kinematic gait parameters are accurate in detecting fall risk, as also confirmed by Sturchio et al []. The authors found that kinematic data extracted from wearable sensors showed greater predictive accuracy for falls than the Hoehn and Yahr scale, which is considered the most robust clinical predictor of falls in individuals with PD. Regarding patients with AD, Huang et al [] reported that impaired memory is strongly associated with an increased fall risk in individuals with MCI and AD. Specifically, the authors identified TUG time, stride speed, and heel-strike angles as effective parameters for assessing fall risk in this population. However, our review identified only a single study addressing this critical aspect, highlighting a clear gap in the literature. Future research should further investigate this area to determine the most relevant biomechanical and cognitive features for fall risk assessment in patients with AD. Differently from neurodegenerative disorders (eg, MS, PD, and AD), in patients with stroke, both balance and gait deficits related to falls were observed. According to Weerdesteyn et al [], stroke-related balance deficits include postural instability and lack of coordination in response to both self-induced and external balance perturbations. Gait deficits related to fall risk include reduced propulsion at push-off, decreased hip and knee flexion during the swing phase, and reduced stability during the stance phase. However, the selected studies [,] did not report specific biomechanical features related to falls in patients with stroke. In future studies, it could be essential to select and extract specific biomechanical features related to falls in this patient population.
Technological Equipment: Considerations and Limitations
Fall risk assessment and fall detection have been investigated using wearable technologies. Among these, accelerometers, IMUs, and insole-based systems were mostly used in the clinical context; for instance, triaxial accelerometers and inertial sensors were widely used in the included studies []. They measure body movement by detecting speed changes and calculating the resultant acceleration from the displacement of a mass element. In rehabilitation research, the most commonly used types of accelerometers include strain gauge, capacitive, piezoresistive, and piezoelectric sensors. These accelerometers typically have 1 to 3 sensing axes, enabling motion detection in 1D, 2D, or 3D. From our literature analysis [,,,,,], it emerged that triaxial accelerometers were combined with gyroscopes and EMG sensors to capture a wide range of motion data. In particular, gyroscopes calculate changes in angular motion by detecting Coriolis forces, which are proportional to the rate of angular rotation of the limb. Integrating accelerometer and EMG data from the lower limb provides more insightful findings, especially in the context of neurorehabilitation; for example, Meyer et al [] collected EMG, accelerometer, and gyroscope data that allowed the investigation of foot drop, which has been identified as one of the most frequent causes of falls in individuals with MS. Interestingly, Tulipani et al [] found significant associations between accelerometer-derived metrics and clinical assessments, notably in balance confidence and fatigue. These findings indicate that wearable sensors can offer a real-time, objective measure of fall risk that aligns well with traditional clinical evaluations. Moreover, we found that the studies on fall risk assessment in PD (10/19, 53%) primarily focused on integrating advanced sensor technologies and complex data analysis methods to monitor, predict, and manage fall risks in patients with PD. Some of these studies (2/19, 11%) used a full-body wearable motion sensor system consisting of 6 sensors (each including a triaxial accelerometer, a gyroscope, and a magnetometer) to detect kinematic gait data. By contrast, Silva de Lima [] developed a triaxial accelerometer combined with a barometer, which automatically detected falls and allowed users to manually report falls via a button press. This dual functionality enabled the collection of accurate real-time data on fall events.
According to a previous review by Ferreira et al [], studies involving wearable sensors for fall risk assessment mainly used 1 accelerometer, which underlines the importance of the use of acceleration data in interpreting scores from standard clinical scales. Data from the wearable sensors were used to detect prefall and unbalanced situations, enabling the identification of fall risk events. This approach aims to reduce short-term fall risk by allowing real-time daily monitoring of participants and providing immediate feedback when a fall risk event is detected.
In this context, some of the studies (7/19, 37%) performed the fall risk assessment in an unsupervised setting. Compared to laboratory settings, real-time fall risk prediction during ADLs is more suitable for detecting fall risk events. This approach allows continuous monitoring and enables alert systems to notify participants when fall risk events are detected. However, Meyer et al [] found that the best performance of the ML model used to predict fall risk was achieved with laboratory data, indicating that controlled environments yield more reliable data for assessing fall risk. Supporting this, some studies have found that specific biomechanical features of gait (ie, speed) can vary depending on whether they are analyzed in the home or laboratory setting; for instance, Carcreff et al [] found that children with cerebral palsy exhibited lower gait speeds in daily life compared to laboratory settings, potentially due to walking barefoot during laboratory-based assessments. Other studies have also observed discrepancies between supervised and unsupervised gait speeds in older adults. Takayanagi et al [] identified a weak correlation between daily life and laboratory gait speeds, with daily speeds being significantly lower. De la Cámara et al [] noted that clinical gait speed measurements might not accurately reflect habitual gait speeds and are influenced by physical, mental, and cognitive health. These studies, which used IMUs, faced limitations such as short walking distances in laboratory settings (2.44-10 meters), which do not adequately represent real-world gait. Even in PD, laboratory assessments do not always mirror daily activity accurately. Toosizadeh et al [] found no significant correlation between laboratory and home gait parameters, possibly due to small sample sizes and methodological differences. Corrà et al [] found that certain laboratory tests can better represent gait speed measured at home. However, the ability to remotely monitor patients at home is beneficial for clinicians because it allows them to assess patients’ motor capacity in their domestic environment. In this sense, both in-laboratory and daily living assessments using wearable sensors can provide complementary insights into PD, enhancing clinical evaluations and patient management.
The sensitivity of supervised versus unsupervised assessments for detecting motor fluctuations in PD remains unclear. Therefore, to enhance clinical care and design personalized interventions, a better understanding of gait disabilities is needed, particularly through comprehensive daily life performance data from IMUs.
Although wearable sensors have shown considerable potential in monitoring and detecting fall risk, it is important to acknowledge their limitations and the challenges associated with their use. One critical point is that predicting a fall is not equivalent to preventing it. Current systems are largely reactive, aiming to detect gait abnormalities or balance impairments before a fall occurs, but they do not directly intervene to prevent the event itself. This distinction is crucial, especially in the context of a rapidly aging global population, where fall-related injuries are expected to increase substantially. Therefore, future research should focus not only on improving prediction accuracy but also on integrating real-time intervention mechanisms (eg, alerts, assistive devices, or environmental modifications) that could help prevent falls in a practical setting [].
Another key challenge lies in ergonomics and user acceptance of wearable technologies. Many current devices lack design considerations for comfort and aesthetics, which can lead to discomfort, skin irritation, or reluctance to use the device, particularly among older adults. These limitations negatively affect long-term adherence and reduce the ecological validity of continuous monitoring solutions. Addressing this issue requires a multidisciplinary approach involving engineers, designers, and end users to codevelop devices that are lightweight and easy to wear. In parallel, user-centered studies should investigate how different sensor placements, materials, and feedback systems influence usability and compliance. By overcoming these ergonomic barriers, wearable technologies can move closer to becoming a truly accessible and effective tool for fall risk management in real-life settings [].
It is also important to note that data loss and signal noise can affect the reliability of sensor-derived features, especially in real-world settings. To mitigate these issues, careful attention must be given to preprocessing strategies and to the design of data acquisition protocols that minimize artefacts and signal interruptions. Moreover, differences in device types, sensor configurations, and data processing pipelines across studies make cross-study comparisons challenging. Standardization efforts and robust preprocessing techniques are essential to enhance the reproducibility and generalizability of the findings.
ML Algorithms and Data Processing
In the studies included in this systematic review, a range of AI techniques were applied to analyze data collected via wearable sensors for assessing fall risk in patients with neurological disorders. DL models were prominently featured [,,]. These models are particularly proficient at processing sequential data and capturing temporal dependencies essential for interpreting complex gait patterns over time. This choice reflects a growing trend of using advanced AI methods to detect the complex patterns of movement disorders that are often overlooked by standard clinical assessments. Besides DL, traditional ML techniques also played a significant role; for instance, feature-based models such as support vector machines or random forests were used to classify patients based on the extracted biomechanical features, such as stride length and turning behavior [,,]. Another crucial aspect identified in the included studies was the preprocessing of sensor data using advanced data fusion and signal processing techniques. These methods prepare the raw data for more effective AI analysis by enhancing data quality and extracting meaningful features. Arpan et al [] used unscented Kalman filter techniques to integrate data from multiple sensors, facilitating a more accurate AI-based prediction of fall events []. Some of the included studies (3/19, 16%) explored the implementation of AI models that operate in real time to provide immediate insights or predictive analytics. This approach is particularly useful in a home monitoring context where immediate feedback can prevent falls [].
Looking ahead, the integration of AI in fall risk assessment could expand in several directions. Tailoring AI models to individual patients’ data over time to adapt to changes in their condition or progression of their neurological disease could improve ongoing monitoring and therapeutic accuracy. By incorporating methodologies that adjust to patient-specific needs and conditions, AI can facilitate more dynamic interventions tailored to the evolving profiles of patients. In a recent study, Espinoza Bernal et al [] used personalized ML algorithms to monitor and adjust individual rehabilitation strategies for patients with stroke. Using data from wearable sensors during a rehabilitation camp, these algorithms provided high classification accuracy and insights into changes in patient mobility. This capability not only demonstrates the potential of AI to adapt to and predict the needs of patients based on real-time data but also highlights its value in managing conditions that affect mobility and stability, enhancing the precision of therapy and potentially improving patient outcomes []. Furthermore, another recent study described neural network models specifically designed to capture the dynamic properties of gait, considering both short-term and long-term dependencies in gait cycles []. This approach allowed for the identification of individual-specific gait signatures, which are particularly useful in understanding and accommodating the unique gait dynamics of survivors of stroke, who often exhibit significant variability in their walking patterns due to neurological impairments []. The personalization of AI models to adapt to individual patient profiles over time promises to enhance the precision of interventions, although as AI models evolve, there is also a growing need for explainable AI that can make AI decisions more transparent and understandable to clinicians. This will be crucial for building trust and facilitating the integration of AI tools into everyday clinical practice. Future advancements should aim to not only refine the predictive accuracy of fall risk but also ensure that the outcome data are accessible and interpretable for all users involved in the care process. A recent study demonstrated the use of wearable sensors coupled with explainable AI techniques to provide detailed insights into muscle activity changes, aiding clinicians in understanding the predictive outcomes of AI models [].
Clinical Considerations and Future Perspectives
Detecting fall risk in individuals with neurological disorders has a primary role in the rehabilitation context. In this review, we identified several biomechanical parameters related to fall risk, as measured by wearable sensors. Data extracted from sensors can provide valuable insights into motor deficits associated with fall risk and guide the development of personalized fall prevention programs. Of note, conventional clinical scales may be not able to capture specific fall-related movements detected by wearable sensors []. This discrepancy highlights the importance of body-worn sensors, combining daily life sensor data with clinical assessment outcomes to enhance fall prediction accuracy. Therefore, daily life data recording should be preferred over in-laboratory data collection, as individuals with neurological disorders are more susceptible to the effects of test instructions or external distractions in controlled settings. However, lower activity levels in individuals with neurological disorders may affect the quality of the data collected. Moreover, both the location and method of sensor attachment are crucial when collecting sensor-based data from individuals with neurological disorders. Using multiple sensors might provide more detailed information but is less practical for this patient group. In addition, researchers or trained staff need to be present to ensure the correct placement and wearing of the sensors. From a practical standpoint, the sensor’s location should be chosen carefully to minimize discomfort during the assessment and avoid interfering with natural movement. Technical considerations, such as battery life, data transmission, and storage capacity, must also be factored in when selecting an appropriate sensor for research or clinical practice.
Future studies should incorporate additional fall risk factors (ie, cognitive status, comorbidities, and sensory functions) that could improve the accuracy of fall risk prediction. They should also consider using multiple sensors to capture more detailed biomechanical information. Innovative technologies such as wearable sensors hold promise for enhancing motion analysis and fall risk prediction due to their increasing simplicity, speed, and ease of interpretation compared to traditional methods. However, there remains a scarcity of studies with practical clinical applications for gait analysis in populations with neurological disorders, particularly in patients with stroke or AD. This gap may be attributed to practical challenges, such as the lack of widely available specialized devices in hospital settings and economic constraints. In addition, the absence of direct collaboration between clinicians and bioengineering professionals contributes to this issue. Increased collaboration between physiotherapists, kinesiologists, and bioengineers is essential for sharing practical insights that inform the development of specific motor training programs based on functional assessments. Technological advancements could address these challenges by promoting the use of smart tools, such as smartphones, which are becoming more prevalent in clinical settings, as supported by some studies [,,]. In parallel, advancements in wearable sensor technology are being complemented by the rapid evolution of AI, particularly through its integration with big data, cloud computing, and Internet of Things platforms. Wearable sensors stand to benefit significantly from these advancements, as AI algorithms enable the efficient processing of large and complex datasets; the extraction of informative features; and the generation of accurate, data-driven decisions. These capabilities extend to a range of functions, including gesture recognition, movement analysis, object detection, and continuous health monitoring []. Moreover, the integration of multimodal sensors to collect various data types such as motion, physiological, and environmental signals offers promising opportunities for enhancing fall risk assessment. While traditional data fusion methods often struggle with the complexity and heterogeneity of such data, DL provides powerful tools to automatically extract and model relationships across multiple sensor modalities [].
Limitations
This systematic review has some limitations that need to be acknowledged. One limitation is the absence of quantitative analysis. In particular, we found considerable heterogeneity among the included studies in terms of sensors used, sensor placement, and biomechanical features extracted; therefore, conducting a quantitative analysis was not feasible. This limitation underscores the need for caution in generalizing the findings and emphasizes the importance of interpreting the results within the context of individual study characteristics. The selected studies also presented other limitations, including small sample sizes, lack of a control group or normative data, and lack of long-term follow-up evaluations. Future large-scale longitudinal studies are warranted to further explore and validate key aspects of fall risk assessment and fall detection in patients with neurological disorders.
Despite these limitations, our review provides a comprehensive qualitative synthesis that systematically summarized and interpreted the findings of individual studies to elucidate common themes, patterns, and discrepancies in the literature. As such, it offers valuable insights into the biomechanical features and wearable sensors used to perform fall risk assessment, identifying key implications for clinical practice and considerations for future investigation.
Conclusions
In this systematic review, we highlighted the critical role of wearable technologies in providing an objective and quantitative assessment of fall risk in patients with neurological disorders. Although the included studies were well executed, we identified significant heterogeneity in sensor placement, types of wearable systems, motor tasks, and evaluation methods. In addition, we observed a tendency among the included studies to primarily focus on technological and engineering aspects, often at the expense of the clinical context. However, the absence of a standardized fall risk assessment using wearable systems is likely attributable to ongoing technological advancements, which can be considered a strength.
Authors' Contributions
AI and MB conceptualized the study. MB, AI, and PDP were responsible for methodology. AI and MB were responsible for software. All authors contributed to validation and visualization. AI was responsible for formal analysis. MB was responsible for investigation. RSC and AQ were responsible for resources. AC and AMDN were responsible for data curation. MB and AI wrote the original draft. RSC reviewed and edited the manuscript. RSC, AC, and AMDN supervised the study. RSC and AMDN were responsible for project administration. AQ was responsible for funding acquisition. All authors have read and agreed to the published version of the manuscript.
Conflicts of Interest
None declared.
PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) checklist.
DOCX File , 25 KBSearch queries.
DOCX File , 15 KBReferences
- Zhu J, Cui Y, Zhang J, Yan R, Su D, Zhao D, et al. Temporal trends in the prevalence of Parkinson's disease from 1980 to 2023: a systematic review and meta-analysis. Lancet Healthy Longev. Jul 2024;5(7):e464-e479. [FREE Full text] [CrossRef] [Medline]
- Walton C, King R, Rechtman L, Kaye W, Leray E, Marrie RA, et al. Rising prevalence of multiple sclerosis worldwide: insights from the Atlas of MS, third edition. Mult Scler. Dec 11, 2020;26(14):1816-1821. [FREE Full text] [CrossRef] [Medline]
- Niu H, Álvarez-Álvarez I, Guillén-Grima F, Aguinaga-Ontoso I. Prevalence and incidence of Alzheimer's disease in Europe: a meta-analysis. Neurología (English Edition). Oct 2017;32(8):523-532. [CrossRef]
- Tahami Monfared AA, Byrnes MJ, White LA, Zhang Q. Alzheimer's disease: epidemiology and clinical progression. Neurol Ther. Jun 14, 2022;11(2):553-569. [FREE Full text] [CrossRef] [Medline]
- Niu H, Álvarez-Álvarez I, Guillén-Grima F, Aguinaga-Ontoso I. Prevalence and incidence of Alzheimer's disease in Europe: A meta-analysis. Neurologia. Oct 2017;32(8):523-532. [FREE Full text] [CrossRef] [Medline]
- GBD 2019 Stroke Collaborators. Global, regional, and national burden of stroke and its risk factors, 1990-2019: a systematic analysis for the Global Burden of Disease Study 2019. Lancet Neurol. Oct 2021;20(10):795-820. [FREE Full text] [CrossRef] [Medline]
- Shankar KN, Li A. Older adult falls in emergency medicine, 2023 update. Clin Geriatr Med. Nov 2023;39(4):503-518. [CrossRef] [Medline]
- Zhou J, Liu B, Ye H, Duan JP. A prospective cohort study on the association between new falls and balancing ability among older adults over 80 years who are independent. Exp Gerontol. Sep 2023;180:112259. [FREE Full text] [CrossRef] [Medline]
- Ehrhardt A, Hostettler P, Widmer L, Reuter K, Petersen JA, Straumann D, et al. Fall-related functional impairments in patients with neurological gait disorder. Sci Rep. Dec 03, 2020;10(1):21120. [FREE Full text] [CrossRef] [Medline]
- Stolze H, Klebe S, Zechlin C, Baecker C, Friege L, Deuschl G. Falls in frequent neurological diseases--prevalence, risk factors and aetiology. J Neurol. Jan 2004;251(1):79-84. [CrossRef] [Medline]
- Kehrer-Dunlap AL, Keleman AA, Bollinger RM, Stark SL. Falls and Alzheimer disease. Adv Geriatr Med Res. 2024;6(1):33. [FREE Full text] [CrossRef] [Medline]
- Bonanno M, De Nunzio AM, Quartarone A, Militi A, Petralito F, Calabrò RS. Gait analysis in neurorehabilitation: from research to clinical practice. Bioengineering (Basel). Jun 30, 2023;10(7):785. [FREE Full text] [CrossRef] [Medline]
- Pistacchi M, Gioulis M, Sanson F, De Giovannini E, Filippi G, Rossetto F, et al. Gait analysis and clinical correlations in early Parkinson's disease. Funct Neurol. 2017;32(1):28-34. [FREE Full text] [CrossRef] [Medline]
- Coca-Tapia M, Cuesta-Gómez A, Molina-Rueda F, Carratalá-Tejada M. Gait pattern in people with multiple sclerosis: a systematic review. Diagnostics (Basel). Mar 24, 2021;11(4):584. [FREE Full text] [CrossRef] [Medline]
- Jensen LE, Padilla R. Effectiveness of interventions to prevent falls in people with Alzheimer's disease and related dementias. Am J Occup Ther. 2011;65(5):532-540. [CrossRef] [Medline]
- Mohan DM, Khandoker AH, Wasti SA, Ismail Ibrahim Ismail Alali S, Jelinek HF, Khalaf K. Assessment methods of post-stroke gait: a scoping review of technology-driven approaches to gait characterization and analysis. Front Neurol. 2021;12:650024. [FREE Full text] [CrossRef] [Medline]
- Roos LG, Slavich GM. Wearable technologies for health research: opportunities, limitations, and practical and conceptual considerations. Brain Behav Immun. Oct 2023;113:444-452. [FREE Full text] [CrossRef] [Medline]
- van Schaik JE, Dominici N. Motion tracking in developmental research: methods, considerations, and applications. Prog Brain Res. 2020;254:89-111. [CrossRef] [Medline]
- De Pasquale P, Bonanno M, Mojdehdehbaher S, Quartarone A, Calabrò RS. The use of head-mounted display systems for upper limb kinematic analysis in post-stroke patients: a perspective review on benefits, challenges and other solutions. Bioengineering (Basel). May 24, 2024;11(6):538. [FREE Full text] [CrossRef] [Medline]
- Teixeira E, Fonseca H, Diniz-Sousa F, Veras L, Boppre G, Oliveira J, et al. Wearable devices for physical activity and healthcare monitoring in elderly people: a critical review. Geriatrics (Basel). Apr 07, 2021;6(2):38. [FREE Full text] [CrossRef] [Medline]
- Subramaniam S, Faisal AI, Deen MJ. Wearable sensor systems for fall risk assessment: a review. Front Digit Health. 2022;4:921506. [FREE Full text] [CrossRef] [Medline]
- Gillespie LD, Robertson MC, Gillespie WJ, Sherrington C, Gates S, Clemson LM, et al. Interventions for preventing falls in older people living in the community. Cochrane Database Syst Rev. Sep 12, 2012;2012(9):CD007146. [FREE Full text] [CrossRef] [Medline]
- Tulipani LJ, Meyer B, Allen D, Solomon AJ, McGinnis RS. Evaluation of unsupervised 30-second chair stand test performance assessed by wearable sensors to predict fall status in multiple sclerosis. Gait Posture. May 2022;94:19-25. [FREE Full text] [CrossRef] [Medline]
- Gu C, Lin W, He X, Zhang L, Zhang M. IMU-based motion capture system for rehabilitation applications: a systematic review. Biomim Intell Robot. Jun 2023;3(2):100097. [CrossRef]
- van Schooten KS, Pijnappels M, Rispens SM, Elders PJ, Lips P, van Dieën JH. Ambulatory fall-risk assessment: amount and quality of daily-life gait predict falls in older adults. J Gerontol A Biol Sci Med Sci. May 2015;70(5):608-615. [CrossRef] [Medline]
- Howcroft J, Lemaire ED, Kofman J. Wearable-sensor-based classification models of faller status in older adults. PLoS One. Apr 7, 2016;11(4):e0153240. [FREE Full text] [CrossRef] [Medline]
- Sylos Labini F, Meli A, Ivanenko YP, Tufarelli D. Recurrence quantification analysis of gait in normal and hypovestibular subjects. Gait Posture. Jan 2012;35(1):48-55. [CrossRef] [Medline]
- Hsu YL, Chung PC, Wang WH, Pai MC, Wang CY, Lin CW, et al. Gait and balance analysis for patients with Alzheimer's disease using an inertial-sensor-based wearable instrument. IEEE J Biomed Health Inform. Nov 2014;18(6):1822-1830. [CrossRef]
- Ravi D, Wong C, Lo B, Yang GZ. A deep learning approach to on-node sensor data analytics for mobile or wearable devices. IEEE J Biomed Health Inform. Jan 2017;21(1):56-64. [CrossRef]
- Romijnders R, Warmerdam E, Hansen C, Schmidt G, Maetzler W. A deep learning approach for gait event detection from a single shank-worn IMU: validation in healthy and neurological cohorts. Sensors (Basel). May 19, 2022;22(10):3859. [FREE Full text] [CrossRef] [Medline]
- Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. Mar 29, 2021;372:n71. [FREE Full text] [CrossRef] [Medline]
- Eriksen MB, Frandsen TF. The impact of patient, intervention, comparison, outcome (PICO) as a search strategy tool on literature search quality: a systematic review. J Med Libr Assoc. Oct 2018;106(4):420-431. [FREE Full text] [CrossRef] [Medline]
- Ouzzani M, Hammady H, Fedorowicz Z, Elmagarmid A. Rayyan-a web and mobile app for systematic reviews. Syst Rev. Dec 05, 2016;5(1):210. [FREE Full text] [CrossRef] [Medline]
- Study quality assessment tools. National Heart Lung and Blood Institute. URL: https://www.nhlbi.nih.gov/health-topics/study-quality-assessment-tools [accessed 2024-04-17]
- Pallavi P, Jariwala N, Patel N, Kanetkar M, Diwan S, Lahiri U. Design of SmartWalk for estimating implication of pathway with turn and task condition on postural and gait indices: relevance to fear of fall. IEEE Trans Neural Syst Rehabil Eng. 2023;31:406-415. [CrossRef] [Medline]
- Taylor-Piliae RE, Mohler MJ, Najafi B, Coull BM. Objective fall risk detection in stroke survivors using wearable sensor technology: a feasibility study. Top Stroke Rehabil. Dec 2016;23(6):393-399. [CrossRef] [Medline]
- Meyer BM, Tulipani LJ, Gurchiek RD, Allen DA, Adamowicz L, Larie D, et al. Wearables and deep learning classify fall risk from gait in multiple sclerosis. IEEE J Biomed Health Inform. May 2021;25(5):1824-1831. [FREE Full text] [CrossRef] [Medline]
- Botonis OK, Harari Y, Embry KR, Mummidisetty CK, Riopelle D, Giffhorn M, et al. Wearable airbag technology and machine learned models to mitigate falls after stroke. J Neuroeng Rehabil. Jun 17, 2022;19(1):60. [FREE Full text] [CrossRef] [Medline]
- Sturchio A, Dwivedi AK, Marsili L, Hadley A, Sobrero G, Heldman D, et al. Kinematic but not clinical measures predict falls in Parkinson-related orthostatic hypotension. J Neurol. Mar 26, 2021;268(3):1006-1015. [FREE Full text] [CrossRef] [Medline]
- Abdollahi M, Rashedi E, Jahangiri S, Kuber PM, Azadeh-Fard N, Dombovy M. Fall risk assessment in stroke survivors: a machine learning model using detailed motion data from common clinical tests and motor-cognitive dual-tasking. Sensors (Basel). Jan 26, 2024;24(3):812. [FREE Full text] [CrossRef] [Medline]
- Tulipani LJ, Meyer B, Larie D, Solomon AJ, McGinnis RS. Metrics extracted from a single wearable sensor during sit-stand transitions relate to mobility impairment and fall risk in people with multiple sclerosis. Gait Posture. Jul 2020;80:361-366. [FREE Full text] [CrossRef] [Medline]
- Silva de Lima AL, Smits T, Darweesh SK, Valenti G, Milosevic M, Pijl M, et al. Home-based monitoring of falls using wearable sensors in Parkinson's disease. Mov Disord. Jan 2020;35(1):109-115. [FREE Full text] [CrossRef] [Medline]
- Nouriani A, Jonason A, Sabal LT, Hanson JT, Jean JN, Lisko T, et al. Real world validation of activity recognition algorithm and development of novel behavioral biomarkers of falls in aged control and movement disorder patients. Front Aging Neurosci. 2023;15:1117802. [FREE Full text] [CrossRef] [Medline]
- Arpan I, Shah VV, McNames J, Harker G, Carlson-Kuhta P, Spain R, et al. Fall prediction based on instrumented measures of gait and turning in daily life in people with multiple sclerosis. Sensors (Basel). Aug 09, 2022;22(16):5940. [FREE Full text] [CrossRef] [Medline]
- Ma L, Mi TM, Jia Q, Han C, Chhetri JK, Chan P. Gait variability is sensitive to detect Parkinson's disease patients at high fall risk. Int J Neurosci. Sep 2022;132(9):888-893. [CrossRef] [Medline]
- Greene BR, Premoli I, McManus K, McGrath D, Caulfield B. Predicting fall counts using wearable sensors: a novel digital biomarker for Parkinson’s disease. Sensors (Basel). Dec 22, 2021;22(1):54. [FREE Full text] [CrossRef] [Medline]
- Song Z, Ou J, Wu S, Shu L, Fu Q, Xu X. Wearable fall risk assessment by discriminating recessive weak foot individual. J Neuroeng Rehabil. Mar 20, 2025;22(1):64. [FREE Full text] [CrossRef] [Medline]
- Meyer BM, Tulipani LJ, Gurchiek RD, Allen DA, Solomon AJ, Cheney N, et al. Open-source dataset reveals relationship between walking bout duration and fall risk classification performance in persons with multiple sclerosis. PLOS Digit Health. Oct 18, 2022;1(10):e0000120. [FREE Full text] [CrossRef] [Medline]
- Ullrich M, Roth N, Kuderle A, Richer R, Gladow T, Gasner H, et al. Fall risk prediction in Parkinson’s disease using real-world inertial sensor gait data. IEEE J Biomed Health Inform. Jan 2023;27(1):319-328. [CrossRef] [Medline]
- Huang S, Zhou X, Liu Y, Luo J, Lv Z, Shang P, et al. High fall risk associated with memory deficit and brain lobes atrophy among elderly with amnestic mild cognitive impairment and mild Alzheimer’s disease. Front Neurosci. 2022;16:896437. [FREE Full text] [CrossRef] [Medline]
- Hildebrand A, Jacobs PG, Folsom JG, Mosquera-Lopez C, Wan E, Cameron MH. Comparing fall detection methods in people with multiple sclerosis: a prospective observational cohort study. Mult Scler Relat Disord. Nov 2021;56:103270. [CrossRef] [Medline]
- Kushner T, Mosquera-Lopez C, Hildebrand A, Cameron MH, Jacobs PG. Risky movement: assessing fall risk in people with multiple sclerosis with wearable sensors and beacon-based smart-home monitoring. Mult Scler Relat Disord. Nov 2023;79:105019. [CrossRef] [Medline]
- Mosquera-Lopez C, Wan E, Shastry M, Folsom J, Leitschuh J, Condon J, et al. Automated detection of real-world falls: modeled from people with multiple sclerosis. IEEE J Biomed Health Inform. Jun 2021;25(6):1975-1984. [CrossRef]
- Greene BR, McManus K, Redmond SJ, Caulfield B, Quinn CC. Digital assessment of falls risk, frailty, and mobility impairment using wearable sensors. NPJ Digit Med. 2019;2:125. [FREE Full text] [CrossRef] [Medline]
- Greene BR, Redmond SJ, Caulfield B. Fall risk assessment through automatic combination of clinical fall risk factors and body-worn sensor data. IEEE J Biomed Health Inform. May 2017;21(3):725-731. [CrossRef] [Medline]
- Huang T, Li M, Huang J. Recent trends in wearable device used to detect freezing of gait and falls in people with Parkinson's disease: a systematic review. Front Aging Neurosci. 2023;15:1119956. [FREE Full text] [CrossRef] [Medline]
- Zhou Y, Zia Ur Rehman R, Hansen C, Maetzler W, Del Din S, Rochester L, et al. Classification of neurological patients to identify fallers based on spatial-temporal gait characteristics measured by a wearable device. Sensors (Basel). Jul 23, 2020;20(15):4098. [FREE Full text] [CrossRef] [Medline]
- Cameron MH, Nilsagard Y. Balance, gait, and falls in multiple sclerosis. Handb Clin Neurol. 2018;159:237-250. [CrossRef] [Medline]
- Cameron MH, Nilsagard Y. Balance, gait, and falls in multiple sclerosis. Handb Clin Neurol. 2018;159:237-250. [CrossRef] [Medline]
- Camicioli R, Morris ME, Pieruccini-Faria F, Montero-Odasso M, Son S, Buzaglo D, et al. Prevention of falls in Parkinson’s disease: guidelines and gaps. Mov Disord Clin Pract. Oct 2023;10(10):1459-1469. [FREE Full text] [CrossRef] [Medline]
- Pelicioni PH, Menant JC, Latt MD, Lord SR. Falls in Parkinson's disease subtypes: risk factors, locations and circumstances. Int J Environ Res Public Health. Jun 23, 2019;16(12):2216. [FREE Full text] [CrossRef] [Medline]
- Weerdesteyn V, de Niet M, van Duijnhoven HJ, Geurts AC. Falls in individuals with stroke. J Rehabil Res Dev. 2008;45(8):1195-1213. [Medline]
- Silva de Lima AL, Evers LJ, Hahn T, Bataille L, Hamilton JL, Little MA, et al. Freezing of gait and fall detection in Parkinson's disease using wearable sensors: a systematic review. J Neurol. Aug 2017;264(8):1642-1654. [FREE Full text] [CrossRef] [Medline]
- Ferreira RN, Ribeiro NF, Santos CP. Fall risk assessment using wearable sensors: a narrative review. Sensors (Basel). Jan 27, 2022;22(3):984. [FREE Full text] [CrossRef] [Medline]
- Carcreff L, Gerber CN, Paraschiv-Ionescu A, De Coulon G, Aminian K, Newman C, et al. Walking speed of children and adolescents with cerebral palsy: laboratory versus daily life. Front Bioeng Biotechnol. 2020;8:812. [FREE Full text] [CrossRef] [Medline]
- Takayanagi N, Sudo M, Yamashiro Y, Lee S, Kobayashi Y, Niki Y, et al. Relationship between daily and in-laboratory gait speed among healthy community-dwelling older adults. Sci Rep. Mar 05, 2019;9(1):3496. [FREE Full text] [CrossRef] [Medline]
- De la Cámara MÁ, Higueras-Fresnillo S, Sadarangani KP, Esteban-Cornejo I, Martinez-Gomez D, Veiga Ó. Clinical and ambulatory gait speed in older adults: associations with several physical, mental, and cognitive health outcomes. Phys Ther. Apr 17, 2020;100(4):718-727. [CrossRef] [Medline]
- Toosizadeh N, Mohler J, Lei H, Parvaneh S, Sherman S, Najafi B. Motor performance assessment in Parkinson’s disease: association between objective in-clinic, objective in-home, and subjective/semi-objective measures. PLoS One. 2015;10(4):e0124763. [FREE Full text] [CrossRef] [Medline]
- Corrà MF, Atrsaei A, Sardoreira A, Hansen C, Aminian K, Correia M, et al. Comparison of laboratory and daily-life gait speed assessment during ON and OFF states in Parkinson’s disease. Sensors (Basel). Jun 09, 2021;21(12):3974. [FREE Full text] [CrossRef] [Medline]
- Li Y, Liu P, Fang Y, Wu X, Xie Y, Xu Z, et al. A decade of progress in wearable sensors for fall detection (2015-2024): a network-based visualization review. Sensors (Basel). Mar 31, 2025;25(7):2205. [FREE Full text] [CrossRef] [Medline]
- Espinoza Bernal VC, Hiremath SV, Wolf B, Riley B, Mendonca RJ, Johnson MJ. Classifying and tracking rehabilitation interventions through machine-learning algorithms in individuals with stroke. J Rehabil Assist Technol Eng. Oct 07, 2021;8:20556683211044640. [FREE Full text] [CrossRef] [Medline]
- Winner TS, Rosenberg MC, Jain K, Kesar TM, Ting LH, Berman GJ. Discovering individual-specific gait signatures from data-driven models of neuromechanical dynamics. PLoS Comput Biol. Oct 27, 2023;19(10):e1011556. [FREE Full text] [CrossRef] [Medline]
- Hussain I, Jany R. Interpreting stroke-impaired electromyography patterns through explainable artificial intelligence. Sensors (Basel). Feb 21, 2024;24(5):1392. [FREE Full text] [CrossRef] [Medline]
- De Pasquale P, Bonanno M, De Marchis C, Pergolizzi L, Lombardo Facciale A, Paladina G, et al. Beyond clinical scales: an observational study on instrumental gait analysis and biomechanical patterns in patients with Parkinson's disease. Front Bioeng Biotechnol. 2025;13:1541240. [FREE Full text] [CrossRef] [Medline]
- Alberto S, Cabral S, Proença J, Pona-Ferreira F, Leitão M, Bouça-Machado R, et al. Validation of quantitative gait analysis systems for Parkinson's disease for use in supervised and unsupervised environments. BMC Neurol. Aug 28, 2021;21(1):331. [FREE Full text] [CrossRef] [Medline]
- Marković V, Stanković I, Radovanović S, Petrović I, Ječmenica Lukić M, Dragašević Mišković N, et al. Gait alterations in Parkinson's disease at the stage of hemiparkinsonism-a longitudinal study. PLoS One. Jul 21, 2022;17(7):e0269886. [FREE Full text] [CrossRef] [Medline]
- Kong L, Song J, Fang Z, Chen H, Fan C, Zhang Z, et al. Artificial intelligence-assisted wearable electronics for human-machine interfaces. Device. Mar 2025;3(3):100707. [CrossRef]
- Tang Q, Liang J, Zhu F. A comparative review on multi-modal sensors fusion based on deep learning. Signal Process. Dec 2023;213:109165. [CrossRef]
Abbreviations
| 30CST: 30-second chair stand test |
| ADL: activity of daily living |
| AI: artificial intelligence |
| AUC: area under the receiver operating characteristic curve |
| DL: deep learning |
| EMG: electromyography |
| IMU: inertial measurement unit |
| LSTM: long short-term memory |
| ML: machine learning |
| MS: multiple sclerosis |
| PD: Parkinson disease |
| PRISMA: Preferred Reporting Items for Systematic Reviews and Meta-Analyses |
| TUG: timed up and go |
Edited by Z Liang; submitted 07.10.24; peer-reviewed by R Valentim, W Qi, D Rubeca; comments to author 16.04.25; revised version received 14.05.25; accepted 20.05.25; published 18.08.25.
Copyright©Mirjam Bonanno, Augusto Ielo, Paolo De Pasquale, Antonio Celesti, Alessandro Marco De Nunzio, Angelo Quartarone, Rocco Salvatore Calabrò. Originally published in JMIR mHealth and uHealth (https://mhealth.jmir.org), 18.08.2025.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on https://mhealth.jmir.org/, as well as this copyright and license information must be included.