Background: Axial spondyloarthritis (axSpA) is an inflammatory rheumatic disease associated with chronic back pain and restricted mobility and physical function. Increasing physical activity is a viable strategy for improving the health and quality of life of patients with axSpA. Thus, quantifying physical activity and sedentary behavior in this population is relevant to clinical outcomes and disease management. However, to the best of our knowledge, no systematic review to date has identified and synthesized the available evidence on the use of wearable devices to objectively measure the physical activity or sedentary behavior of patients with axSpA.
Objective: This study aimed to review the literature on the use of wearable activity trackers as outcome measures for physical activity and sedentary behavior in patients with axSpA.
Methods: PubMed, PEDro, and Cochrane electronic databases were searched in July 2021 for relevant original articles, with no limits on publication dates. Studies were included if they were original articles, targeted adults with a diagnosis of axSpA, and reported wearable device–measured physical activity or sedentary behavior among patients with axSpA. Data regarding the study’s characteristics, the sample description, the methods used for measuring physical activity and sedentary behavior (eg, wearable devices, assessment methods, and outcomes), and the main results of the physical activity and sedentary behavior assessments were extracted.
Results: A total of 31 studies were initially identified; 13 (13/31, 42%) met the inclusion criteria, including 819 patients with axSpA. All the studies used accelerometer-based wearable devices to assess physical activity. Of the 13 studies, 4 (4/31, 31%) studies also reported outcomes related to sedentary behavior. Wearable devices were secured on the wrists (3/13 studies, 23%), lower back (3/13, 23%), right hip (3/13, 23%), waist (2/13, 15%), anterior thigh (1/13, 8%), or right arm (1/13, 8%). The methods for reporting physical activity and sedentary behavior were heterogeneous. Approximately 77% (10/13) of studies had a monitoring period of 1 week, including weekend days.
Conclusions: To date, few studies have used wearable devices to quantify the physical activity and sedentary behavior of patients with axSpA. The methodologies and results were heterogeneous, and none of these studies assessed the psychometric properties of these wearables in this specific population. Further investigation in this direction is needed before using wearable device–measured physical activity and sedentary behavior as outcome measures in intervention studies in patients with axSpA.
Trial Registration: PROSPERO CRD42020182398; https://tinyurl.com/ec22jzkt
International Registered Report Identifier (IRRID): RR2-10.2196/23359
doi:10.2196/34734
Keywords
Introduction
Axial spondyloarthritis (axSpA) is a chronic inflammatory rheumatic disease that can cause inflammatory back pain, structural damage, and disability [
]. New therapeutic agents allow for effective therapy [ ]. Physical activity should be an integral part of standard care, according to current guidelines [ ], because of its multiple health benefits, including pain reduction [ , ], increased mobility [ - ], physical function [ - ], and cardiorespiratory fitness [ ], which ultimately reduces disease activity [ - , , ]. Furthermore, increasing physical activity represents a viable strategy for improving quality of life [ , ] and reducing the psychological comorbidities of patients with axSpA [ ]. Physical activity is a predictor of mortality and cardiovascular events in the general population [ ]. In addition, high-intensity exercises (12 weeks of endurance and strength exercises) have been reported to significantly improve disease activity and reduce cardiovascular risks in patients with axSpA [ ]. However, a good therapeutic response depends on short symptom duration and close disease monitoring [ ]. A recent review reported that most measures of physical activity used in patients with axSpA were “subjective and limited by patient recall, reporting bias, and relatively short study intervals” [ ].Wearable technology comprises “a device fitted to the participant’s body which detects and collects data” [
]. These wearables can include accelerometers, pedometers, or inertial measurement units, which are small and transportable. They can be advantageously used to monitor physical activity data under real-world conditions in various chronic populations [ - ], including patients with axSpA [ , - ]. By allowing longitudinal physical activity monitoring, these devices can remotely monitor the disease and evolution of health status in patients with axSpA [ , ]. Indeed, greater disease activity is associated with lower levels of physical activity in axSpA and could help detect flares [ , ].In addition to measuring physical activity, in a complementary manner, wearables can measure the time spent sitting, also called sedentary behavior. Indeed, it is of particular interest in patients with axSpA as the more time patients with axSpA spend sitting, the greater the association with disease activity [
], decreased physical function [ ], and decreased quality of life [ ].Thus, physical activity and sedentary behavior assessments using wearable devices represent an attractive and feasible health monitoring option for patients with axSpA. Interestingly, a multicentric prospective observational study, which involved 157 patients with chronic inflammatory rheumatic diseases, found good acceptability of wearing activity trackers for physical activity assessment in this population [
].However, to the best of our knowledge, no study has assessed the use of wearables to objectively monitor physical activity and sedentary behavior in patients with axSpA. We designed the present review to identify and synthesize the currently available evidence on the use of wearable activity trackers as outcome measures for physical activity and sedentary behavior in patients with axSpA [
]. We aimed to answer the following research question: which wearable devices, assessment methods, and associated outcomes are commonly used to quantify physical activity or sedentary behavior among patients with axSpA?Methods
This systematic review’s protocol was developed based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. It was registered in PROSPERO (International Prospective Register of Systematic Reviews; CRD42020182398) and was published in November 2021 [
].Inclusion Criteria
Studies were included if they (1) were original articles published in English-language peer-reviewed journals, (2) targeted adults (aged ≥18 years) with a diagnosis of axSpA, and (3) reported wearable device–measured physical activity or sedentary behavior among patients with axSpA.
Studies were excluded if they (1) were case reports, abstracts, editorials, conference abstracts, letters to the editor, reviews, or meta-analyses or (2) did not use wearable devices to quantify the physical activity or sedentary behavior of patients with axSpA.
Data Sources and Search Strategy
In July 2021, we conducted searches with no date restrictions in 3 electronic bibliographic databases (PubMed, PEDro, and Cochrane). The Boolean operators AND and OR were used to combine keywords relevant to the population, wearable devices, and the outcomes of physical activity or sedentary behavior and were searched in all fields. The detailed search strategy is presented in the review protocol recently published in JMIR Research Protocols [
].Study Selection
A total of 2 independent reviewers (TC and JS) screened the titles, abstracts, and keywords of all the studies found in the search to identify potentially relevant articles. Duplicates were manually removed. The selected full-length text articles were then screened for eligibility according to the criteria abovementioned. In cases of disagreement, the reviewers reached a consensus through discussion. If their disagreement persisted, a third reviewer (NV) was asked to make the final decision. In accordance with the PRISMA guidelines [
], a flow chart was constructed to summarize each step of the selection process with its corresponding number of citations ( ).Risk of Bias in Individual Studies
As indicated in the published review protocol [
], as the purpose of this review was not to assess the clinical effects of interventions, we did not perform a risk of bias assessment [ - ]. Indeed, as mentioned in the Introduction section, this review was designed to identify and synthesize the available evidence on the use of wearable devices to quantify physical activity or sedentary behavior among patients with axSpA.Data Extraction
Data extraction was performed independently by 2 reviewers (TC and JS) who were not blinded to the authors or journals. Information was extracted on (1) the study’s characteristics, (2) the sample description, (3) the methods used for measuring physical activity and sedentary behavior (eg, wearable devices, assessment methods, and outcomes), and (4) the main results of the physical activity and sedentary behavior assessments.
Data Synthesis and Analysis
Owing to the significant heterogeneity of data types, we decided to perform only a narrative synthesis [
, ]. As per the data extraction strategy, the tables and figures found in this review only summarize the available information on wearable devices used to objectively assess the physical activity and sedentary behavior of patients with axSpA.Results
Study Selection
The study selection process is illustrated in
. A preliminary search of the 3 electronic bibliographic databases identified 31 citations. A duplicate was removed, leaving 97% (30/31) of unique records for preliminary screening, focusing on the title, abstract, and keywords. Finally, of the 30 articles, 13 (43%) met our eligibility criteria and were included in this review.Study Characteristics
The characteristics of the studies included (N=13) are outlined in
.First author | Year of publication | Country | Study design | Outcomes of interest |
Arends et al [ | ]2013 | The Netherlands | Observational validation study | Physical activity |
Bayraktar et al [ | ]2021 | Turkey | Cross-sectional study | Physical activity |
Carbo et al [ | ]2021 | The Netherlands | Part of a prospective, longitudinal, observational cohort study | Physical activity |
Coulter et al [ | ]2019 | United Kingdom | Prospective cohort study | Physical activity and sedentary behavior |
Gossec et al [ | ]2019 | France | Prospective, multicenter, longitudinal, observational study | Physical activity and sedentary behavior |
Jacquemin et al [ | ]2017 | France | Prospective, multicenter, longitudinal, observational study | Physical activity |
Jacquemin et al [ | ]2018 | France | Prospective, multicenter, longitudinal, observational study | Physical activity |
O’Dwyer et al [ | ]2015 | Ireland | Cross-sectional controlled study | Physical activity and sedentary behavior |
Plasqui et al [ | ]2012 | The Netherlands | Observational case-control study | Physical activity |
Swinnen et al [ | ]2014 | Belgium | Observational cross-sectional controlled study | Physical activity and sedentary behavior |
van Genderen et al [ | ]2015 | The Netherlands | Multicenter cross-sectional study | Physical activity |
van Genderen et al [ | ]2014 | The Netherlands | Cross-sectional case-control study | Physical activity |
Yuksel et al [ | ]2021 | Turkey | Observational cross-sectional controlled study | Physical activity |
Most studies were conducted in Europe (11/13, 85%), namely, the Netherlands (5/13, 38%) [
, , - ], France (3/13, 23%) [ , , ], the United Kingdom (1/13, 8%) [ ], Ireland (1/13, 8%) [ ], and Belgium (1/13, 8%) [ ]. Approximately 15% (2/13) of studies were conducted in Turkey [ , ]. Designs of the 13 studies included 1 (8%) observational validation study [ ], 1 (8%) reproducibility study [ ], 4 (31%) longitudinal studies [ , - ], and 7 (54%) cross-sectional studies [ , , , , - ]. None of the studies reported interventions for the levels of physical activity or lifestyle. All studies (13/13, 100%) [ , , , - , - ] focused on assessing physical activity and reported at least one corresponding outcome, whereas some studies (4/13, 31%) also reported outcomes related to sedentary behavior in patients with axSpA [ , , , ].Sample Characteristics
presents participants’ descriptive characteristics. The 13 studies included covered a total of 819 patients with axSpA, of whom 490 (59.8%) were male. The mean sample size was 63 (SD 33.1), ranging from 24 [ ] to 135 [ ] participants with axSpA. The mean patient age was 44.43 (SD 4.4) years. Disease diagnoses were based on the Assessment of Spondyloarthritis international Society recommendations (6/13, 46%) [ , - , , ], the modified New York criteria (4/13, 31%) [ , , , ], or both (2/13, 15%) [ , ]. Approximately 8% (1/13) of studies used the European Spondyloarthropathy Study Group recommendations for disease diagnosis [ ]. Mean or median disease duration ranged from 4 [ ] to 20.5 years [ ].
All the studies used the Bath Ankylosing Spondylitis Disease Activity Index (13/13, 100%) [
, , , - , - ], with mean or median scores ranging from 3.1 [ ] to 4.5 [ ]. Approximately 85% (11/13) studies used the Bath Ankylosing Spondylitis Functional Index [ , , , , , , - ], with mean or median scores ranging from 1.7 [ ] to 4.4 [ ]. Approximately 31% (4/13) of studies used the Bath Ankylosing Spondylitis Metrology Index [ , , , ], with mean scores ranging from 1.8 [ , ] to 3.05 [ ].Approximately 54% (7/13) studies included a healthy control group [
, , , , - ], including 281 healthy participants, of whom 169 (60.1%) were male. The mean sample size was 40.14 (SD 27.2), ranging from 24 [ ] to 99 [ ] control participants. The mean participant age across the healthy control groups was 42.56 (SD 16.8) years.First author | Participants, N | Males, n (%) | Age (years), mean (SD) or median (IQR)b | BMI, mean (SD) or median (IQR)b | Duration (years), mean (SD) or median (IQR)b | Criteria for diagnosis | BASFIc score, mean (SD) or median (IQR)b | BASDAId score, mean (SD) or median (IQR)b | BASMIe score, mean (SD) or median (IQR)b | ||||||||||
Arends et al [ | ]115 | 71 (62) | 44.6 (12.1) | 26.4 (4.4) | 10.0 (0-42)b | ASASf+NYg | 3.8 (2.4) | 3.7 (0-9)b | —h | ||||||||||
Bayraktar et al [ | ]58 | 32 (55) | 39.0 (30.0-46.0)b | 26.1 (23.7-28.7)b | 4 (3-10) | ASAS | 2.2 (0.5-3.8)b | 2.8 (1.4-4.7)b | 1.8 (1.1-2.95)b | ||||||||||
Carbo et al [ | ]45 | 23 (51) | 50.7 (11.6) | — | 27.0 (18-36)b | ASAS+NY | 3.3 (1.4-5.7)b | 3.4 (2.0-5.7)b | — | ||||||||||
Coulter et al [ | ]45 | 23 (46) | 49.0 (11.7) | 27.4 (5.6) | 15.6 (11.2) | ASAS | 4.4 (2.6) | 4.5 (2.3) | 3.6 (1.8) | ||||||||||
Gossec et al [ | ]73 | 41 (56.2) | 41.2 (10.3) | 24.6 (4.6) | 10.8 (9.1) | ASAS | — | 3.1 (2.0) | — | ||||||||||
Jacquemin et al [ | ]79 | 44 (55.7) | 41.4 (10.2) | 25.0 (4.6) | 10.4 (8.9) | ASAS | — | 3.3 (2.1) | — | ||||||||||
Jacquemin et al [ | ]74 | 43 (58.1) | 41.3 (10.4) | 25.3 (4.6) | 10.4 (9.1) | ASAS | 1.7 (1.8) | 3.2 (2.1) | — | ||||||||||
O’Dwyer et al [ | ]39 | 32 (82.1) | 40.0 (9.0) | 28.6 (6.8) | 6.0 (10.0) | NY | 2.9 (3.8) | 3.6 (2.2) | — | ||||||||||
Plasqui et al [ | ]25 | 15 (60) | 48.0 (11.0) | 26.2 (5.0) | 19.0 (12.0) | NY | 4.0 (2.2) | 4.3 (2.2) | — | ||||||||||
Swinnen et al [ | ]40 | 24 (60) | 44.38 (11.3) | 26.3 (5.1) | 11.4 (9.5) | ESSGi | 3.52 (2.5) | 3.7 (2.6) | 3.1 (1.2) | ||||||||||
van Genderen et al [ | ]24 | 14 (58.3) | 48.0 (11.0) | 26.0 (4.6)b | 20.5 (22.0)b | NY | 3.8 (2.1)b | 4.0 (3.7)b | — | ||||||||||
van Genderen et al [ | ]135 | 81 (80) | 51.0 (13.0) | 26 (4.3) | 16.5 (12.1) | NY | 4.1 (2.6) | 4.3 (2.2) | — | ||||||||||
Yuksel et al [ | ]|||||||||||||||||||
ASj | 34 | 47 (70.1) | 41.0 (31-46)b | 26.1 (22.9-29.6)b | 8.0 (4-13)b | ASAS | 2.4 (0.5-3.9)b | 3.4 (1.5-5.8)b | 2.1 (1.5-3.9)b | ||||||||||
Nr-SpAk | 33 | 47 (70.1) | 37.0 (32-40)e | 26.3 (25.4-28.7)e | 4.0 (2-9)e | ASAS | 1.2 (0.6-2.9)e | 2.4 (1.4-5.4)e | 1.5 (1.1-2.0)e |
aaxSpA: axial spondyloarthritis.
bOutcomes are reported with median (IQR) values.
cBASFI: Bath Ankylosing Spondylitis Functional Index.
dBASDAI: Bath Ankylosing Spondylitis Disease Activity Index.
eBASMI: Bath Ankylosing Spondylitis Metrology Index.
fASAS: Assessment of Spondyloarthritis international Society.
gNY: modified New York criteria.
hNot available
iESSG: European Spondyloarthropathy Study Group.
jAS: ankylosing spondylitis.
knr-SpA: nonradiologic form of axial spondyloarthritis.
Methods of Measuring Physical Activity and Sedentary Behavior
presents the methods used to objectively assess physical activity or sedentary behavior among patients with axSpA. Information regarding wearable devices (eg, device name, manufacturer, and sensor), assessment methods (device location, length of monitoring, requisite conditions for valid monitoring, visualization of physical activity by the participants, and instructions to the participants on physical activity), and outcomes (physical activity and sedentary behavior) are reported.
First author | Device name | Manufacturer (country) | Sensor | Device location | Length of monitoring | Requisite conditions for valid monitoring | Visualization of physical activity by the participants | Instructions to the participants on physical activity | Outcomes reported |
Arends et al [ | ]The ActiGraph: GT1M | ActiGraph (United States) | Uniaxial accelerometer | Right hip | 7 consecutive days | Minimum wear time of 10 hours per day and 5 days with both weekend day | No information | No information | Kilocounts per day and mean wear time |
Bayraktar et al [ | ]GT3X | ActiGraph (United States) | Triaxial accelerometer | Waist | 7 consecutive days | Patients not wearing accelerometer as instructed (<10 hours per day wear; <7 days total wear) were removed from the analysis | No information | No information | Total activity duration and activity duration intensity (light or moderate or vigorous); METsa for total and for each physical activity intensities |
Carbo et al [ | ]GT3X | ActiGraph (United States) | Triaxial accelerometer | Right hip | 7 consecutive days | Data excluded if accelerometer worn <10 hours per day, for <5 days or for <2 weekend days | No information | No information | Total activity kilocounts and activity duration intensity (light, moderate, and vigorous) in minutes per week |
Coulter et al [ | ]The activPAL3 | PAL Technologies Ltd (Scotland) | Triaxial accelerometer | Anterior thigh of the dominant leg | 7 consecutive days | Minimum wear time of 24 hours for a valid day | No information | No information | Daily standing, walking, sedentary time, and steps per day |
Gossec et al [ | ]Withings Activité Pop | Withings (France) | —b | Wrist | 90 consecutive days | — | “patients could visualize their physical activity on their smartphones.” | “No instruction about physical activity was given to the participants” | Steps per minute |
Jacquemin et a. [ | ]Withing Activité Pop | Withings (France) | — | Wrist | 90 consecutive days | — | “patients could visualize their physical activity on their smartphones.” | “No instruction about physical activity was given to the participants” | Steps per day, total activity duration, and activity duration in moderate to vigorous intensity |
Jacquemin et al [ | ]Withing Activité Pop | Withings (France) | — | Wrist | 90 consecutive days | — | No information | “No intervention was specifically performed to increase physical activity, and no instruction about physical activity was given to the participants.” | Steps per day, morning step count, total activity duration, and activity duration in moderate to vigorous intensity |
O’Dwyer et al [ | ]RT3 | Stayhealthy Inc (United States) | Triaxial accelerometer | Right hip | 7 consecutive days | Minimum wear time of 10 hours per day, including at least one weekend day | No information | No information | Counts per day |
Plasqui et al [ | ]Tracmor | Philips Research (the Netherlands) | 3 uniaxial piezoelectric accelerometers | Lower back | 7 consecutive days | — | No information | No information | Kilocounts per day |
Swinnen et al [ | ]SenseWear Pro 3 Armband | Bodymedia Inc (United States) | Biaxial accelerometer | Right triceps muscle | 5 consecutive days | Minimum wear time of 1296 minutes, corresponding to 90% of a 24-hour period, including both weekend days | No information | No information | Weekly average of kilocounts per day |
van Genderen et al [ | ]Tracmor | Philips Research (the Netherlands) | 3 uniaxial piezoelectric accelerometers | Lower back | 7 consecutive days | Minimum wear time of 10 hours for a valid day | No information | No information | Kilocounts per day and mean wear time |
van Genderen et al [ | ]GT3X | ActiGraph (United States) | Triaxial accelerometer | Lower back | 7 consecutive days | Minimum wear time of 10 hours for a valid day | No information | No information | Vector magnitude counts, counts per day, and counts per minute |
Yuksel et al [ | ]GT3X | ActiGraph (United States) | Triaxial accelerometer | Waist | 7 consecutive days | Not specified; however, participants “instructed to wear the device for at least 10 h/day except for water-related activities such as showering or swimming” | No information | No information | Activity duration (light, moderate, vigorous) in minutes per week |
aMET: metabolic equivalent of task.
bNot available
All studies (13/13, 100%) [
, , , - , - ] reported wearable device–measured physical activity outcomes, whereas some (4/13, 40%) studies reported wearable device–measured sedentary behavior outcomes among patients with axSpA [ , , , ]. Only 15% (2/13) of studies provided information on the visualization of physical activity levels by the participants [ , ], and 23% (3/13) of studies provided instructions to the participants on physical activity [ , , ].Types of Sensors
All 13 studies used accelerometer-based wearable devices, with 6 (46%) using triaxial accelerometers [
, , - , ], 2 (15%) using 3 uniaxial piezoelectric accelerometers [ , ], 1 (8%) using a biaxial accelerometer [ ], and 1 (8%) using a uniaxial accelerometer [ ]. Approximately 23% (3/13) of studies did not mention the type of accelerometer [ , , ]. The brands used were ActiGraph (5/13, 38%) [ , - , ], Withings (3/13, 23%) [ , , ], Philips Research (2/13, 15%) [ , ], PAL Technologies (1/13, 8%) [ ], Stayhealthy (1/13, 8%) [ ], and Bodymedia (1/13, 8%) [ ].The Withings device was the Withing Activité Pop, an accelerometer-based activity tracker worn on the wrist. ActiGraph devices included the GT1M, a uniaxial accelerometer fixed on the participant’s right hip, and the GT3X, a triaxial accelerometer placed on the lower back using a belt. The Tracmor sensor is a combination of 3 uniaxial piezoelectric accelerometers that are fixed to the lower back. PAL Technologies’ activPAL3 is a triaxial accelerometer fixed to the anterior thigh of a participant’s dominant leg. Stayhealthy’s RT3 is a triaxial accelerometer worn on the right hip. Bodymedia’s SenseWear Pro 3 Armband is a biaxial accelerometer worn on the back of the right triceps muscle.
Wearable devices were secured on the wrist (3/13, 23%) [
, , ], lower back (3/13, 23%) [ , , ], right hip (3/13, 23%) [ , , ], waist (2/13, 15%) [ , ], anterior thigh of the dominant leg (1/13, 8%) [ ], and right arm (1/13, 8%) [ ].Monitoring Protocol
Approximately 69% (9/13) of studies used 1-week monitoring (7 consecutive days) [
, , , , - ], and 8% (1/13) used a 5-day period (including both weekend days) [ ]. Approximately 23% (3/13) of studies used 3-month monitoring and follow-up [ , , ]. None of the studies assessed only days of the week. Monitoring was considered complete when wearable devices were worn on both weekend days in 38% (5/13) of studies [ , , , , ] or when 1 weekend day was included in the follow-up period in 8% (1/13) of studies [ ]. Approximately 54% (7/13) of studies imposed wearing the tracker for at least 10 hours per day [ , , - ], 10% (1/13) imposed wearing trackers for at least 1296 minutes (corresponding to 90% of 24 hours) [ ], and 10% (1/13) imposed a minimum wear time of 24 hours per day [ ]. Approximately 23% (3/13) of studies reported wear time [ , , ] and 23% (3/13) others reported activity duration or time spent on specific activities (walking and standing) [ , , ].Physical Activity Outcomes
Twelve objective measures of physical activity were used to assess patients with axSpA in the 13 studies: 4 (31%) studies reported steps per day [
, - ], 6 (46%) reported activity counts [ , , , - ], 4 (46%) reported total activity duration [ , , , ], 2 (15%) reported energy expenditure [ , ], 2 (15%) reported levels of physical activity [ , ], and 4 (31%) reported average wear time in hours per day [ , , , ]. Approximately 69% (9/13) of studies also reported activity intensity [ , , - , - , ] using six different expressions of measurement: light, moderate, vigorous, and very vigorous levels of activity levels [ , , - , ]; minutes spent in moderate to vigorous activity [ , , - ]; and mean walking-event cadence [ ].The number of steps per day was reported as the average daily step count [
, - ]. Activity counts were reported as the average of daily activity counts [ , , , , ]. Total activity duration was reported as the sum of minutes involving at least 20 steps recorded in a week [ ] or as active minutes in a day, derived from either step count (minutes with at least 20 steps recorded) [ ] or activity count [ ]. Energy expenditure was expressed as the metabolic equivalent of task (MET) hours per day [ ] or MET minutes per week [ ]. METs were used to report the overall and objective levels of physical activity in 15% (2/13) of studies [ , ]. Activity intensity was obtained from activity counts [ , , , ] or number of steps [ , ]. Established cutoff points were used to convert raw data from daily activity counts [ , ] or MET values [ , ] into each activity intensity. The average time spent doing light, moderate, and vigorous activities was reported in minutes per day [ , , ] or hours per day [ ]. One of the studies reported the score for very vigorous activity and expressed it in minutes per day [ ]. The time spent performing light to vigorous activities was expressed in minutes per day [ , , ] or minutes per week [ , , , , ]. Another study reported cadence using steps per minute [ ].Sedentary Behavior Outcomes
A total of 5 measures were used to assess sedentary behavior in patients with axSpA. These included (1) the number of sitting events (1/13, 8%) [
], (2) total sitting time (1/13, 8%) [ ], (3) the number of bouts of prolonged sitting time (>30 minutes; 1/13, 8%) [ ], (4) the total duration of this prolonged sitting time (1/13, 8%) [ ], and (5) duration of sedentary behavior (3/13, 23%) [ , , ].Cutoff values based on daily activity counts [
, ] or MET values [ , ] were used to derive sedentary time from the raw data. Coulter et al [ ] also reported sitting events per day, duration of sitting time in hours per day, and the number of periods of prolonged sitting time (>30 minutes).Discussion
To the best of our knowledge, this is the first systematic review to identify and synthesize available evidence on the use of wearable activity trackers as outcome measures for physical activity and sedentary behavior in patients with axSpA. For the sake of clarity, we discuss our findings through three main themes: (1) the wearable devices themselves, (2) reference outcomes for physical activity and sedentary behavior assessment using wearable devices, and (3) monitoring protocols and assessment methods.
Wearable Devices
Our findings showed the broad use of wearable devices, mostly incorporating triaxial accelerometers [
, , , - ], and less use of simple devices such as pedometers [ , , ] or uniaxial or biaxial accelerometers [ , ]. Among the studies included in our synthesis of directly comparable data ( ), accelerometers were the most frequently used direct measuring devices.To implement these wearables in clinical practice, measurements should be both feasible (ie, used by patients and health professionals) and accurate (ie, validity and reliability) [
- ].Monitoring of health and physical activity seems feasible in patients with axSpA. Indeed, in a recent study by Jacquemin et al [
], 157 patients reported that wearing a wristwatch-type device for 3 months was acceptable, with a mean acceptability score of 8 out of 10 [ ]. However, the interpretation of the data provided by these devices requires digital health skills that not every patient with axSpA may have. The implementation of wearables in clinical practice also necessitates the formation and training of health professionals supporting patients with the use of wearable activity trackers. None of the included studies have addressed this issue.Depending on their purpose (ie, with specific conditions of use), the validity of activity trackers can vary significantly, making them more or less suitable for research purposes. Some activity trackers are specifically designed for research purposes (research activity trackers), with relatively short-term use, fewer needs for the interface with the users, and more precise and detailed parameters. This is the case for the ActiGraph [
, ], Philips Research [ ], and ActivPAL [ , ] sensors, which have been widely validated against doubly labeled water in healthy control populations and presented a high degree of accuracy [ - ]. Other activity trackers (such as Fitbit or Withings devices) are primarily designed for consumers to monitor and improve their physical activity levels, are easy to wear, and are adapted for long-term use. At this point, it is important to note that previous studies have reported that the validity of these devices is lower than that of research activity trackers [ - ], the estimation of energy expenditure was outside the acceptable accuracy [ - ], and the availability of raw data is not always warranted.Interestingly, we found no published studies assessing the psychometric properties of wearable devices to monitor physical activity and sedentary behavior in our specific population, neither in free-living conditions nor in a more standardized environment, such as a laboratory. Therefore, it would be appropriate to conduct studies addressing the metrological properties of these devices in this population. Importantly, patients with axSpA seem to present with motor and gait specificities [
, ] that could affect the validity of wearables designed to monitor walking activity.The positioning of the wearable devices on the body should also be considered. The 3 main locations used were the wrist [
, , ], lower back [ , , ], and hip [ , , ]. In the general population, previous studies have reported that where devices are placed on the body has a significant impact on the accuracy of the number of steps counted during various walking activities [ , , , ]. The major trend reported in these studies was the outperformance of hip-worn devices. For example, in the laboratory-based validation protocol described by Kooiman et al [ ], a hip-worn activity tracker (Fitbit Zip, Fitbit Inc) had the highest validity and reliability in counting healthy participants’ steps. Hip-mounted devices were also the best for counting steps at the preferred walking speeds of healthy individuals, with a lower absolute mean relative error [ ]. However, when walking speeds decreased, the wrist-worn devices in the same study provided more accurate step count estimations than the hip-worn devices [ ].Previous studies have shown that physical activity and sedentary behavior can be modified in patients with axSpA compared with healthy controls. Indeed, if no significant differences were found between patients with axSpA and healthy controls in light physical activity [
, , , ], counts per day [ , , , ], or duration of sedentary behavior [ , , ], 31% (4/13) of studies found that patients with axSpA performed significantly less vigorous activity [ , , , ]. Results regarding durations of moderate or moderate to vigorous activity were inconsistent (ie, some studies found significantly less moderate physical activity [ , ] or moderate to vigorous activity [ ] in patients with axSpA, whereas others did not [ , ]).Moreover, considering the symptoms caused by spondyloarthritis, such as limitations in the sagittal range of motion of the lower limbs during gait [
, ] and lower gait speed [ ], previous results in the literature regarding wearable devices in axSpA may be questionable. Future studies on how the location of wearable devices affects the overall accuracy of measurements of physical activity and sedentary behavior among this specific population are needed, particularly regarding the gait specificities of patients with axSpA [ , ].Furthermore, only 15% (2/13) of studies mentioned that participants could visualize physical activity [
, ], and 23% (3/13) of studies mentioned that they provided no instructions on physical activity [ , , ]. Wearing a wearable tracker and visualizing physical activity can increase the physical activity of participants [ ]. Thus, future studies on wearables and physical activity should include information on visualization and instructions on physical activity.Reference Outcomes for Physical Activity and Sedentary Behavior Assessment Using Wearable Devices
The studies included in this systematic review reported two main categories of outcomes related to physical activity: first, the number of daily steps taken [
, - ], and second, data based on the daily activity counts recorded by accelerometers [ , , , , - ]. These 2 types of data allowed us to estimate the time spent doing activities of different intensities (ie, light, moderate, or vigorous). In other words, using threshold values, it is possible to estimate the intensity of an activity based on the number of steps or activity counts.In contrast, even if recording the number of steps per day (4/13, 31% studies) [
, - ] requires fewer raw data than recording the activity count, parameters related to the activity count were used slightly more for tracking individual behavior (9/13, 69% studies) [ , , - , - , ]. Indeed, monitoring techniques based on activity count data require devices with greater memory and storage capacity; however, recent technological advances have made data compression and storage problems almost irrelevant. There is extensive literature related to activity count cutoff points [ - ] but not to step cutoff points, which could explain why activity counts were more common in the present review. Further investigation in a laboratory-type setting is needed to draw firm conclusions on the pros and cons of each measurement method in the axSpA population. It would also be appropriate to determine specific cutoff points for this population for both step and activity counts.Using thresholds allowed us to categorize low, moderate, vigorous, and very vigorous activities. However, in line with the recommended levels of physical activity already stated for the general population [
], and especially in this population [ ], we believe that it would be preferable to group individuals’ moderate-intensity and vigorous-intensity activities into one moderate to vigorous activity category [ ], which would also facilitate future comparisons with the rest of the literature.Another way of expressing physical activity levels is by using METs. METs are a method of expressing an activity’s energy costs, and they refer to energy expenditure rather than an activity’s intensity. Using METs would seem to be more relevant and more likely to accurately report an individual’s true level of physical activity or energy expenditure [
]. Nevertheless, the lack of available data did not allow us to validate this outcome’s use among pathological populations; therefore, using kilocalories was a preferable way of expressing energy expenditure. An increasing number of studies used activity counts to report physical activity levels in the axSpA patient population [ , , , , ]; however, it would seem advisable to assess this outcome under standardized laboratory and open-field conditions.The number of daily steps remains the outcome of choice for monitoring an individual’s activity level [
, - ]. This enables the particularly straightforward detection of decreases in ambulatory activities that prevent the onset of runaway evolution in the disease or marked disease flares [ ]. As one of the studies already addressed this question by linking daily numbers of steps over 3 months to acute disease flare-ups [ ], we believe that data over longer periods could also be of interest. Just as Tudor-Locke et al [ ] reported changes in daily activity patterns over the course of a year, we think it would be interesting to track the daily number of steps taken by patients with axSpA over 1 year.The literature concerning assessments of sedentary behavior is much more scattered, and more studies are needed to confirm the trends reported to date. As with the intensity of physical activity, sedentary behavior can be defined using certain thresholds. Some researchers have used activity count [
, , ], whereas others have estimated sedentary behavior using METs provided by the manufacturers’ algorithms [ ].At present, only one method of monitoring sedentary behavior exists for patients with axSpA, although it has different outcomes. This method uses wearable trackers and the acceleration data obtained from them. The outcomes are overall reports of sedentary time based on thresholds and detailed reports of sitting times and the number of sitting events.
To increase the monitoring precision and for comparative purposes, we suggest that all studies clearly mention the duration of carrying the wearable devices.
Monitoring Protocols and Assessment Methods
The studies included in this systematic review reported two ways of monitoring sedentary behavior and physical activity levels of patients with axSpA. We found studies with short follow-up periods of 5 to 7 days [
, , , , , - ] and others with follow-up periods of >90 days [ , , ], depending on each study’s objectives. Importantly, sufficient daily wear time and a sufficient number of follow-up days, including specific weekend days, had to be ensured for that follow-up to be valid. Interestingly, all studies included weekends in their monitoring. For example, Gossec et al [ ] identified the critical time intervals for classifying activities and tracking accuracy. These authors also reported that the significantly different activities performed on Saturday afternoons were associated with the detection of axSpA flare-ups and changes in flare-up state [ ]. When examining the general population data [ ], the days of the week included in the follow-up may have influenced the monitoring results. Furthermore, owing to the technical properties of wearable devices, some activities, such as swimming, could not be monitored.The length of monitoring (ie, 1 week or several weeks) and days included in the monitoring (ie, weekday, workday, day off, and weekend) should be harmonized as they influence physical activity performance [
, , ]. If reliable results can often be found with 1 week of monitoring, longer monitoring can help health professionals capture days of the week in which the participant is always inactive to further adapt the intervention program [ ].Limitations and Perspectives of the Review
Wearable trackers are promising as they have the potential to better monitor the physical activity and sedentary behavior evolution of patients with axSpA and study its impact on the disease. Mobile health, including trackers, permits health monitoring when outside health structures and could limit the number of visits to the hospital or clinic [
]. The literature on wearable trackers is rapidly building, and it is possible that some studies were published between the search and publication of this review. Moreover, most systematic reviews were limited by the small number of studies included. To avoid this, the search strategy included all fields and was not limited to the titles and abstracts. We used a thorough systematic and transparent methodology to conduct this review [ ]. Despite this, only a few studies were included in the review, and we encountered some challenges when comparing across studies because of varying methods and reported results.Furthermore, although the present review did not focus on the role of wearables as interventions to improve physical activity and sedentary behavior, this area of research could represent a relevant future research direction. Indeed, trackers can also be used as an intervention to motivate users to increase physical activity and decrease sedentary behavior [
, , - ] and could further prevent inactivity- or sedentary-related diseases (eg, cardiovascular diseases) [ ].Conclusions
This review identified and synthesized currently available evidence on the use of wearable activity trackers as outcome measures for physical activity and sedentary behavior in patients with axSpA.
We have underlined some trends regarding (1) the types of wearable devices used, (2) the outcomes reported, and (3) the follow-up protocols used. To date, few studies have used wearable devices to quantify physical activity among patients with axSpA, and the methods used have been heterogeneous. To fill this gap in knowledge and the literature, we suggest that future research focus on testing the feasibility and accuracy of physical activity and sedentary behavior assessments in patients with axSpA. The best locations to position the sensors should also be considered. This should occur in both the short-term, controlled, and supervised conditions of a laboratory environment and the long-term, varied, and everyday conditions of normal living environments.
Acknowledgments
This work was partly supported by the French National Research Agency within the framework of the Investissements d’avenir program (ANR-10-AIRT-05 and ANR-15-IDEX-02). The sponsors had no involvement in the study design, collection, analysis, and interpretation of data or in writing the manuscript. This study also forms part of a broader translational and interdisciplinary GaitAlps research program (NV).
Authors' Contributions
NV designed the systematic review protocol. JS and TC searched for and selected the articles included in this review and extracted data from the articles. JS and TC drafted the first version of the manuscript. JK and NV critically revised the article for important intellectual content. All authors read and approved the final version and agreed to be accountable for all aspects related to the accuracy or integrity of the work.
Conflicts of Interest
None declared.
References
- Sieper J, Rudwaleit M, Baraliakos X, Brandt J, Braun J, Burgos-Vargas R, et al. The Assessment of SpondyloArthritis international Society (ASAS) handbook: a guide to assess spondyloarthritis. Ann Rheum Dis 2009 Jul 11;68 Suppl 2(Suppl 2):ii1-i44. [CrossRef] [Medline]
- Dubash S, McGonagle D, Marzo-Ortega H. New advances in the understanding and treatment of axial spondyloarthritis: from chance to choice. Ther Adv Chronic Dis 2018 Mar;9(3):77-87 [FREE Full text] [CrossRef] [Medline]
- Kiltz U, Landewé RB, van der Heijde D, Rudwaleit M, Weisman MH, Akkoc N, et al. Development of ASAS quality standards to improve the quality of health and care services for patients with axial spondyloarthritis. Ann Rheum Dis 2020 Feb 11;79(2):193-201 [FREE Full text] [CrossRef] [Medline]
- Zão A, Cantista P. The role of land and aquatic exercise in ankylosing spondylitis: a systematic review. Rheumatol Int 2017 Dec 5;37(12):1979-1990. [CrossRef] [Medline]
- Millner JR, Barron JS, Beinke KM, Butterworth RH, Chasle BE, Dutton LJ, et al. Exercise for ankylosing spondylitis: an evidence-based consensus statement. Semin Arthritis Rheum 2016 Mar;45(4):411-427 [FREE Full text] [CrossRef] [Medline]
- Liang H, Xu L, Tian X, Wang S, Liu X, Dai Y, et al. The comparative efficacy of supervised- versus home-based exercise programs in patients with ankylosing spondylitis: a meta-analysis. Medicine (Baltimore) 2020 Mar;99(8):e19229 [FREE Full text] [CrossRef] [Medline]
- Liang H, Zhang H, Ji H, Wang C. Effects of home-based exercise intervention on health-related quality of life for patients with ankylosing spondylitis: a meta-analysis. Clin Rheumatol 2015 Oct 15;34(10):1737-1744. [CrossRef] [Medline]
- Pécourneau V, Degboé Y, Barnetche T, Cantagrel A, Constantin A, Ruyssen-Witrand A. Effectiveness of exercise programs in ankylosing spondylitis: a meta-analysis of randomized controlled trials. Arch Phys Med Rehabil 2018 Feb;99(2):383-9.e1. [CrossRef] [Medline]
- Saracoglu I, Kurt G, Okur EO, Afsar E, Seyyar GK, Calik BB, et al. The effectiveness of specific exercise types on cardiopulmonary functions in patients with ankylosing spondylitis: a systematic review. Rheumatol Int 2017 Mar 11;37(3):409-421. [CrossRef] [Medline]
- Verhoeven F, Guillot X, Prati C, Mougin F, Tordi N, Demougeot C, et al. Aerobic exercise for axial spondyloarthritis - its effects on disease activity and function as compared to standard physiotherapy: a systematic review and meta-analysis. Int J Rheum Dis 2019 Mar;22(2):234-241. [CrossRef] [Medline]
- Arends S, Hofman M, Kamsma YP, van der Veer E, Houtman PM, Kallenberg CG, et al. Daily physical activity in ankylosing spondylitis: validity and reliability of the IPAQ and SQUASH and the relation with clinical assessments. Arthritis Res Ther 2013 Aug 23;15(4):R99 [FREE Full text] [CrossRef] [Medline]
- Lear SA, Hu W, Rangarajan S, Gasevic D, Leong D, Iqbal R, et al. The effect of physical activity on mortality and cardiovascular disease in 130 000 people from 17 high-income, middle-income, and low-income countries: the PURE study. Lancet 2017 Dec 16;390(10113):2643-2654. [CrossRef] [Medline]
- Sveaas SH, Berg IJ, Provan SA, Semb AG, Hagen KB, Vøllestad N, et al. Efficacy of high intensity exercise on disease activity and cardiovascular risk in active axial spondyloarthritis: a randomized controlled pilot study. PLoS One 2014;9(9):e108688 [FREE Full text] [CrossRef] [Medline]
- Poddubnyy D, Sieper J. Treatment of axial spondyloarthritis: what does the future hold? Curr Rheumatol Rep 2020 Jul 20;22(9):47 [FREE Full text] [CrossRef] [Medline]
- Deodhar A, Gensler LS, Magrey M, Walsh JA, Winseck A, Grant D, et al. Assessing physical activity and sleep in axial spondyloarthritis: measuring the gap. Rheumatol Ther 2019 Dec 31;6(4):487-501 [FREE Full text] [CrossRef] [Medline]
- Pericleous P, van Staa TP. The use of wearable technology to monitor physical activity in patients with COPD: a literature review. Int J Chron Obstruct Pulmon Dis 2019;14:1317-1322 [FREE Full text] [CrossRef] [Medline]
- Phillips SM, Cadmus-Bertram L, Rosenberg D, Buman MP, Lynch BM. Wearable technology and physical activity in chronic disease: opportunities and challenges. Am J Prev Med 2018 Jan;54(1):144-150 [FREE Full text] [CrossRef] [Medline]
- Hammond-Haley M, Allen C, Han J, Patterson T, Marber M, Redwood S. Utility of wearable physical activity monitors in cardiovascular disease: a systematic review of 11464 patients and recommendations for optimal use. Eur Heart J Digit Health 2021 Jun;2(2):231-243. [CrossRef]
- Brophy S, Cooksey R, Davies H, Dennis MS, Zhou S, Siebert S. The effect of physical activity and motivation on function in ankylosing spondylitis: a cohort study. Semin Arthritis Rheum 2013 Jul;42(6):619-626 [FREE Full text] [CrossRef] [Medline]
- Gossec L, Guyard F, Leroy D, Lafargue T, Seiler M, Jacquemin C, et al. Detection of flares by decrease in physical activity, collected using wearable activity trackers in rheumatoid arthritis or axial spondyloarthritis: an application of machine learning analyses in rheumatology. Arthritis Care Res (Hoboken) 2019 Oct;71(10):1336-1343. [CrossRef] [Medline]
- Swinnen TW, Scheers T, Lefevre J, Dankaerts W, Westhovens R, de Vlam K. Physical activity assessment in patients with axial spondyloarthritis compared to healthy controls: a technology-based approach. PLoS One 2014 Feb 28;9(2):e85309 [FREE Full text] [CrossRef] [Medline]
- Fongen C, Halvorsen S, Dagfinrud H. High disease activity is related to low levels of physical activity in patients with ankylosing spondylitis. Clin Rheumatol 2013 Dec 31;32(12):1719-1725. [CrossRef] [Medline]
- Haglund E, Bergman S, Petersson IF, Jacobsson LT, Strömbeck B, Bremander A. Differences in physical activity patterns in patients with spondylarthritis. Arthritis Care Res (Hoboken) 2012 Dec 28;64(12):1886-1894 [FREE Full text] [CrossRef] [Medline]
- Manning VL, Hurley MV, Scott DL, Bearne LM. Are patients meeting the updated physical activity guidelines? Physical activity participation, recommendation, and preferences among inner-city adults with rheumatic diseases. J Clin Rheumatol 2012;18(8):399-404. [CrossRef]
- Fabre S, Molto A, Dadoun S, Rein C, Hudry C, Kreis S, et al. Physical activity in patients with axial spondyloarthritis: a cross-sectional study of 203 patients. Rheumatol Int 2016 Dec 24;36(12):1711-1718. [CrossRef] [Medline]
- Niedermann K, Sidelnikov E, Muggli C, Dagfinrud H, Hermann M, Tamborrini G, et al. Effect of cardiovascular training on fitness and perceived disease activity in people with ankylosing spondylitis. Arthritis Care Res (Hoboken) 2013 Dec 01;65(11):1844-1852 [FREE Full text] [CrossRef] [Medline]
- O'Dwyer T, O'Shea F, Wilson F. Decreased physical activity and cardiorespiratory fitness in adults with ankylosing spondylitis: a cross-sectional controlled study. Rheumatol Int 2015 Dec 9;35(11):1863-1872. [CrossRef] [Medline]
- Plasqui G, Boonen A, Geusens P, Kroot EJ, Starmans M, van der Linden S. Physical activity and body composition in patients with ankylosing spondylitis. Arthritis Care Res (Hoboken) 2012 Jan 28;64(1):101-107 [FREE Full text] [CrossRef] [Medline]
- Jacquemin C, Molto A, Servy H, Sellam J, Foltz V, Gandjbakhch F, et al. Flares assessed weekly in patients with rheumatoid arthritis or axial spondyloarthritis and relationship with physical activity measured using a connected activity tracker: a 3-month study. RMD Open 2017 Jun 29;3(1):e000434 [FREE Full text] [CrossRef] [Medline]
- Coulter EH, McDonald MT, Cameron S, Siebert S, Paul L. Physical activity and sedentary behaviour and their associations with clinical measures in axial spondyloarthritis. Rheumatol Int 2020 Mar 17;40(3):375-381 [FREE Full text] [CrossRef] [Medline]
- Jacquemin C, Servy H, Molto A, Sellam J, Foltz V, Gandjbakhch F, et al. Physical activity assessment using an activity tracker in patients with rheumatoid arthritis and axial spondyloarthritis: prospective observational study. JMIR Mhealth Uhealth 2018 Jan 02;6(1):e1 [FREE Full text] [CrossRef] [Medline]
- Carlin T, Soulard J, Aubourg T, Knitza J, Vuillerme N. Objective measurements of physical activity and sedentary behavior using wearable devices in patients with axial spondyloarthritis: protocol for a systematic review. JMIR Res Protoc 2021 Dec 25;10(11):e23359 [FREE Full text] [CrossRef] [Medline]
- Moher D, Liberati A, Tetzlaff J, Altman DG, PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 2009 Jul 21;6(7):e1000097 [FREE Full text] [CrossRef] [Medline]
- Mustapa A, Justine M, Mohd Mustafah N, Jamil N, Manaf H. Postural control and gait performance in the diabetic peripheral neuropathy: a systematic review. Biomed Res Int 2016;2016:9305025 [FREE Full text] [CrossRef] [Medline]
- Parreira RB, Grecco LA, Oliveira CS. Postural control in blind individuals: a systematic review. Gait Posture 2017 Sep;57:161-167. [CrossRef] [Medline]
- Soulard J, Vaillant J, Agier C, Vuillerme N. Gait characteristics in patients with ankylosing spondylitis: a systematic review. Clin Exp Rheumatol 2021;39(1):173-186 [FREE Full text] [Medline]
- St Fleur RG, St George SM, Leite R, Kobayashi M, Agosto Y, Jake-Schoffman DE. Use of fitbit devices in physical activity intervention studies across the life course: narrative review. JMIR Mhealth Uhealth 2021 May 28;9(5):e23411 [FREE Full text] [CrossRef] [Medline]
- Wurz A, Brunet J. The effects of physical activity on health and quality of life in adolescent cancer survivors: a systematic review. JMIR Cancer 2016 May 24;2(1):e6 [FREE Full text] [CrossRef] [Medline]
- Bayraktar D, Yuksel Karsli T, Ozer Kaya D, Sarac DC, Gucenmez S, Gercik O, et al. Is the international physical activity questionnaire (IPAQ) a valid assessment tool for measuring physical activity of patients with axial spondyloartritis? Musculoskelet Sci Pract 2021 Oct;55:102418. [CrossRef] [Medline]
- Carbo MJ, Paap D, Maas F, Baron AJ, van Overbeeke LC, Siderius M, et al. The mSQUASH; a valid, reliable and responsive questionnaire for daily physical activity in patients with axial spondyloarthritis. Semin Arthritis Rheum 2021 Aug;51(4):719-727 [FREE Full text] [CrossRef] [Medline]
- van Genderen S, Boonen A, van der Heijde D, Heuft L, Luime J, Spoorenberg A, et al. Accelerometer quantification of physical activity and activity patterns in patients with ankylosing spondylitis and population controls. J Rheumatol 2015 Dec 01;42(12):2369-2375. [CrossRef] [Medline]
- van Genderen S, van den Borne C, Geusens P, van der Linden S, Boonen A, Plasqui G. Physical functioning in patients with ankylosing spondylitis. J Clin Rheumatol 2014;20(3):133-137. [CrossRef]
- Yuksel Karsli T, Bayraktar D, Ozer Kaya D, Oz HE, Gucenmez S, Gercik O, et al. Comparison of physical activity levels among different sub-types of axial spondyloarthritis patients and healthy controls. Mod Rheumatol 2021 Dec;31(6):1202-1207 [FREE Full text] [CrossRef] [Medline]
- Evenson KR, Goto MM, Furberg RD. Systematic review of the validity and reliability of consumer-wearable activity trackers. Int J Behav Nutr Phys Act 2015 Dec 18;12:159 [FREE Full text] [CrossRef] [Medline]
- Straiton N, Alharbi M, Bauman A, Neubeck L, Gullick J, Bhindi R, et al. The validity and reliability of consumer-grade activity trackers in older, community-dwelling adults: a systematic review. Maturitas 2018 Jul;112:85-93. [CrossRef] [Medline]
- Kooiman TJ, Dontje ML, Sprenger SR, Krijnen WP, van der Schans CP, de Groot M. Reliability and validity of ten consumer activity trackers. BMC Sports Sci Med Rehabil 2015;7:24 [FREE Full text] [CrossRef] [Medline]
- Plasqui G, Westerterp KR. Physical activity assessment with accelerometers: an evaluation against doubly labeled water. Obesity (Silver Spring) 2007 Oct;15(10):2371-2379 [FREE Full text] [CrossRef] [Medline]
- Plasqui G, Bonomi AG, Westerterp KR. Daily physical activity assessment with accelerometers: new insights and validation studies. Obes Rev 2013 Jul;14(6):451-462. [CrossRef] [Medline]
- Skipworth RJ, Stene GB, Dahele M, Hendry PO, Small AC, Blum D, European Palliative Care Research Collaborative (EPCRC). Patient-focused endpoints in advanced cancer: criterion-based validation of accelerometer-based activity monitoring. Clin Nutr 2011 Dec;30(6):812-821. [CrossRef] [Medline]
- Redenius N, Kim Y, Byun W. Concurrent validity of the Fitbit for assessing sedentary behavior and moderate-to-vigorous physical activity. BMC Med Res Methodol 2019 Feb 07;19(1):29 [FREE Full text] [CrossRef] [Medline]
- Brewer W, Swanson BT, Ortiz A. Validity of Fitbit's active minutes as compared with a research-grade accelerometer and self-reported measures. BMJ Open Sport Exerc Med 2017;3(1):e000254 [FREE Full text] [CrossRef] [Medline]
- Reid RE, Insogna JA, Carver TE, Comptour AM, Bewski NA, Sciortino C, et al. Validity and reliability of Fitbit activity monitors compared to ActiGraph GT3X+ with female adults in a free-living environment. J Sci Med Sport 2017 Jul;20(6):578-582. [CrossRef] [Medline]
- Roberts-Lewis SF, White CM, Ashworth M, Rose MR. Validity of Fitbit activity monitoring for adults with progressive muscle diseases. Disabil Rehabil 2021 Oct 31:1-11. [CrossRef] [Medline]
- Fuller D, Colwell E, Low J, Orychock K, Tobin MA, Simango B, et al. Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: systematic review. JMIR Mhealth Uhealth 2020 Sep 08;8(9):e18694 [FREE Full text] [CrossRef] [Medline]
- Xie J, Wen D, Liang L, Jia Y, Gao L, Lei J. Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: comparative study. JMIR Mhealth Uhealth 2018 May 12;6(4):e94 [FREE Full text] [CrossRef] [Medline]
- Siddall AG, Powell SD, Needham-Beck SC, Edwards VC, Thompson JES, Kefyalew SS, et al. Validity of energy expenditure estimation methods during 10 days of military training. Scand J Med Sci Sports 2019 Oct;29(9):1313-1321. [CrossRef] [Medline]
- Leung W, Case L, Sung M, Jung J. A meta-analysis of Fitbit devices: same company, different models, different validity evidence. J Med Eng Technol 2022 Mar;46(2):102-115. [CrossRef] [Medline]
- Soulard J, Vaillant J, Vuillerme N. Gait in patients with axial spondyloarthritis: a systematic review of the literature. Curr Rheumatol Rev 2022 Sep 21;18(2):117-123. [CrossRef] [Medline]
- Sears T, Avalos E, Lawson S, Eschbach C, Bunn J. Wrist-worn physical activity trackers tend to underestimate steps during walking. Int J Exerc Sci 2017;10:764-773.
- Ehrler F, Weber C, Lovis C. Influence of pedometer position on pedometer accuracy at various walking speeds: a comparative study. J Med Internet Res 2016 Oct 06;18(10):e268 [FREE Full text] [CrossRef] [Medline]
- Zebouni L, Helliwell PS, Howe A, Wright V. Gait analysis in ankylosing spondylitis. Ann Rheum Dis 1992 Jul 01;51(7):898-899 [FREE Full text] [CrossRef] [Medline]
- Del Din S, Carraro E, Sawacha Z, Guiotto A, Bonaldo L, Masiero S, et al. Impaired gait in ankylosing spondylitis. Med Biol Eng Comput 2011 Jul;49(7):801-809. [CrossRef] [Medline]
- Soulard J, Vaillant J, Baillet A, Gaudin P, Vuillerme N. Gait and axial spondyloarthritis: comparative gait analysis study using foot-worn inertial sensors. JMIR Mhealth Uhealth 2021 Nov 09;9(11):e27087 [FREE Full text] [CrossRef] [Medline]
- Brickwood K, Watson G, O'Brien J, Williams AD. Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis. JMIR Mhealth Uhealth 2019 Apr 12;7(4):e11819 [FREE Full text] [CrossRef] [Medline]
- Tudor-Locke C, Camhi S, Troiano R. A catalog of rules, variables, and definitions applied to accelerometer data in the National Health and Nutrition Examination Survey, 2003-2006. Prev Chronic Dis 2012 Jun;9:E113 [FREE Full text] [CrossRef] [Medline]
- Troiano RP, Berrigan D, Dodd KW, Mâsse LC, Tilert T, McDowell M. Physical activity in the United States measured by accelerometer. Med Sci Sports Exerc 2008 Jan;40(1):181-188. [CrossRef] [Medline]
- Matthews CE, Chen KY, Freedson PS, Buchowski MS, Beech BM, Pate RR, et al. Amount of time spent in sedentary behaviors in the United States, 2003-2004. Am J Epidemiol 2008 May 01;167(7):875-881 [FREE Full text] [CrossRef] [Medline]
- Aguilar-Farías N, Brown WJ, Peeters GM. ActiGraph GT3X+ cut-points for identifying sedentary behaviour in older adults in free-living environments. J Sci Med Sport 2014 May;17(3):293-299. [CrossRef] [Medline]
- Sasaki JE, John D, Freedson PS. Validation and comparison of ActiGraph activity monitors. J Sci Med Sport 2011 Oct;14(5):411-416. [CrossRef] [Medline]
- Freedson PS, Melanson E, Sirard J. Calibration of the computer science and applications, Inc. accelerometer. Med Sci Sports Exerc 1998 May;30(5):777-781. [CrossRef] [Medline]
- Copeland J, Esliger D. Accelerometer assessment of physical activity in active, healthy older adults. J Aging Phys Act 2009 Jan;17(1):17-30. [CrossRef] [Medline]
- Global Recommendations on Physical Activity for Health. Genève: World Health Organization; Jan 1, 2010.
- Rausch Osthoff A, Niedermann K, Braun J, Adams J, Brodin N, Dagfinrud H, et al. 2018 EULAR recommendations for physical activity in people with inflammatory arthritis and osteoarthritis. Ann Rheum Dis 2018 Sep;77(9):1251-1260. [CrossRef] [Medline]
- Lai T, Liao Y, Lin C, Huang W, Hsueh M, Chan D. Moderate-to-vigorous physical activity duration is more important than timing for physical function in older adults. Sci Rep 2020 Dec 07;10(1):21344 [FREE Full text] [CrossRef] [Medline]
- Casey B, Coote S, Donnelly A. Objective physical activity measurement in people with multiple sclerosis: a review of the literature. Disabil Rehabil Assist Technol 2018 Feb 13;13(2):124-131. [CrossRef] [Medline]
- Bassett DR, Toth LP, LaMunion SR, Crouter SE. Step counting: a review of measurement considerations and health-related applications. Sports Med 2017 Jul 22;47(7):1303-1315 [FREE Full text] [CrossRef] [Medline]
- Saint-Maurice PF, Troiano RP, Bassett DR, Graubard BI, Carlson SA, Shiroma EJ, et al. Association of daily step count and step intensity with mortality among US adults. JAMA 2020 Mar 24;323(12):1151-1160 [FREE Full text] [CrossRef] [Medline]
- Tudor-Locke CE, Myers AM. Methodological considerations for researchers and practitioners using pedometers to measure physical (ambulatory) activity. Res Q Exerc Sport 2001 Mar;72(1):1-12. [CrossRef] [Medline]
- Tudor-Locke C, Williams JE, Reis JP, Pluto D. Utility of pedometers for assessing physical activity: convergent validity. Sports Med 2002;32(12):795-808. [CrossRef] [Medline]
- Berlin J, Storti K, Brach J. Using activity monitors to measure physical activity in free-living conditions. Phys Ther 2006 Aug;86(8):1137-1145. [Medline]
- Pasanen S, Halonen JI, Pulakka A, Kestens Y, Thierry B, Brondeel R, et al. Contexts of sedentary time and physical activity among ageing workers and recent retirees: cross-sectional GPS and accelerometer study. BMJ Open 2021 May 18;11(5):e042600 [FREE Full text] [CrossRef] [Medline]
- Seppen BF, den Boer P, Wiegel J, Ter Wee MM, van der Leeden M, de Vries R, et al. Asynchronous mHealth interventions in rheumatoid arthritis: systematic scoping review. JMIR Mhealth Uhealth 2020 Nov 05;8(11):e19260 [FREE Full text] [CrossRef] [Medline]
- Böhm B, Karwiese SD, Böhm H, Oberhoffer R. Effects of mobile health including wearable activity trackers to increase physical activity outcomes among healthy children and adolescents: systematic review. JMIR Mhealth Uhealth 2019 Apr 30;7(4):e8298 [FREE Full text] [CrossRef] [Medline]
- Laranjo L, Ding D, Heleno B, Kocaballi B, Quiroz JC, Tong HL, et al. Do smartphone applications and activity trackers increase physical activity in adults? Systematic review, meta-analysis and metaregression. Br J Sports Med 2021 May;55(8):422-432. [CrossRef] [Medline]
- Tang MS, Moore K, McGavigan A, Clark RA, Ganesan AN. Effectiveness of wearable trackers on physical activity in healthy adults: systematic review and meta-analysis of randomized controlled trials. JMIR Mhealth Uhealth 2020 Jul 22;8(7):e15576 [FREE Full text] [CrossRef] [Medline]
Abbreviations
axSpA: axial spondyloarthritis |
MET: metabolic equivalents task |
PRISMA: Preferred Reporting Items for Systematic Reviews and Meta-Analyses |
PROSPERO: International Prospective Register of Systematic Reviews |
Edited by L Buis; submitted 05.11.21; peer-reviewed by C Romanzini, T Vliet Vlieland, RG St Fleur; comments to author 18.01.22; revised version received 02.02.22; accepted 21.03.22; published 22.08.22
Copyright©Julie Soulard, Thomas Carlin, Johannes Knitza, Nicolas Vuillerme. Originally published in JMIR mHealth and uHealth (https://mhealth.jmir.org), 22.08.2022.
This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mHealth and uHealth, is properly cited. The complete bibliographic information, a link to the original publication on https://mhealth.jmir.org/, as well as this copyright and license information must be included.